Search
Advanced search
Filter by category
Filter by committee
Search results
-
A new ASTM International standard will support the sustainability and resiliency of concrete pipes that are reinforced by synthetic fibers. The new standard (soon to be approved as C1818, Specification for Rigid Synthetic Fiber Reinforced Concrete Culvert, Storm Drain and Sewer Pipe) describes a strong and durable option that can be used for underground piping. Pipes in this new standard are used…, ASTM Committee C13 on Concrete Pipe Next Meeting:, Nov. 15-18, 2015, November Committee Week, Tampa, Fla., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Ali Abolmaali, University of Texas, Arlington, Texas, tel +1.817.272.3877; abolmaail@uta.edu, ASTM Staff Contact:, Diane Lake, tel +1.610.832.9661; dlake@astm.org Release #9940
-
Precast reinforced concrete box sections are proving to be a versatile means for the development of infrastructure. The use of segmental box sections is now covered in an ASTM standard, ASTM C1786 , Specification for Segmental Precast Reinforced Concrete Box Sections for Culverts, Storm Drains and Sewers Designed According to AASHTO LRFD. The American Association of State Highway and…, Technical Contact:, Josiah W. Beakley, American Concrete Pipe Association, Irving, Texas, tel +1.972.894.2906; jbeakley@concrete-pipe.org, ASTM Staff Contact:, Diane Lake, tel +1.610.832.9661; dlake@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9745
-
Since the late 1970s, precast box sections have become an important component in the construction of culverts, storm drains and sewers, but there has not been a comprehensive standard for the installation of such sections. A new ASTM International standard fills this gap. ASTM C1675, Practice for Installation of Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains and…, Technical Contact:, Roman Selig, Hamilton Kent LLC, Birmingham, Ala., Phone: 205-910-0690; roman.selig@hamiltonkent.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9243
-
Load and resistance factor design methodology developed by the American Association of State Highway and Transportation Officials plays a key role in a proposed ASTM standard on the design of culverts and storm drains. ASTM WK38166 , Specification for Manufacture of Precast Reinforced Concrete Three-Sided Structures for Culverts and Storm Drains Designed According to AASHTO LRFD, is being…, Technical Contact:, Balaram K. Singh, P.E., Michigan Department of Transportation, Lansing, Mich., Phone: 517-335-2174; singhb@michigan.gov, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact, : Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9311
-
New regulations set forth by the U.S. Environmental Protection Agency to mandate greenhouse gas reporting in the U.S. carbon black industry have led to the development of a new ASTM International standard, ASTM D7662 , Test Method for Carbon Content in Carbon Black Feedstock Oils. ASTM D7662 is under the jurisdiction of Subcommittee D24.66 on Environment, Health and Safety, part of ASTM…
-
The U.S. Environmental Protection Agency has set forth new regulations that mandate greenhouse gas reporting in the U.S. carbon black industry. These regulations were the impetus for the development of a new ASTM International standard, ASTM D7633 , Test Method for Carbon Black Carbon Content. The new standard was developed by Subcommittee D24.66 on Environment, Health and Safety, part of ASTM…, ASTM Committee D24 Next Meeting:, Dec. 6-8, December Committee Week, New Orleans, La., Technical Contact:, George Joyce, Columbian Chemicals Co., Marietta, Ga., Phone: 770-792-9467; gjoyce@columbianchemicals.com, ASTM Staff Contact:, Joe Koury, Phone: 610-832-9804; jkoury@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8641
-
An increased interest in the polyaromatic hydrocarbon content of carbon black, particularly in Europe, and new U.S. Environmental Protection Agency requirements to report greenhouse gas emissions from U.S. industry including carbon black plants has led to the formation of a new ASTM subcommittee. Subcommittee D24.66 on Environment, Health and Safety is part of ASTM International Committee D24 on…
-
ASTM International Committee C13 on Concrete Pipe has approved a new standard that covers flexible joints for concrete box sections using rubber gaskets for leak resistant joints. Subcommittee C13.08 on Joints for Precast Concrete Structures developed ASTM C1677 , Specification for Joints for Concrete Box, Using Rubber Gaskets. “This specification will provide a uniform minimum level of…
-
No industry standard currently exists that addresses the vacuum sealing requirements of knife-edged flanges for high vacuum applications. Existing international standards focus on interchangeability of the hardware, but do not address the reliability of the seal. ASTM International Committee E42 on Surface Analysis is now working on a proposed standard on the subject, WK21206 , Specification…
-
A 2002 workshop on galling wear held by ASTM International Committee G02 on Wear and Erosion provided the impetus for the development of a new standard, ASTM G196 , Test Method for Galling Resistance of Material Couples. The new standard is under the jurisdiction of Subcommittee G02.40 on Non-Abrasive Wear. According to Scott Hummel, Ph.D., associate professor, head of the department of…