Search
Advanced search
Filter by category
Filter by committee
Search results
-
A new ASTM International standard will support the sustainability and resiliency of concrete pipes that are reinforced by synthetic fibers. The new standard (soon to be approved as C1818, Specification for Rigid Synthetic Fiber Reinforced Concrete Culvert, Storm Drain and Sewer Pipe) describes a strong and durable option that can be used for underground piping. Pipes in this new standard are used…, ASTM Committee C13 on Concrete Pipe Next Meeting:, Nov. 15-18, 2015, November Committee Week, Tampa, Fla., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Ali Abolmaali, University of Texas, Arlington, Texas, tel +1.817.272.3877; abolmaail@uta.edu, ASTM Staff Contact:, Diane Lake, tel +1.610.832.9661; dlake@astm.org Release #9940
-
A proposed ASTM standard could help improve workplace safety by describing proximity alarm systems that can be used to prevent cranes, utility trucks, and other equipment from encroaching inside OSHA minimum approach distances and contacting high-voltage power lines. The standard would be most useful to the construction industry, but it could also help in firefighting, drilling, mining,…, ASTM Committee F18 on Electrical Protective Equipment for Workers Next Meeting:, Oct. 4-7, 2015, Las Vegas, Nev., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Lance Burney, Sigalarm, Sanford, Fla., tel +1.407.321.0722; lance@sigalarminc.com , ASTM Staff Contact:, Kevin Shanahan, tel +1.610.832.9737; kshanahan@astm.org Release #9903
-
Precast reinforced concrete box sections are proving to be a versatile means for the development of infrastructure. The use of segmental box sections is now covered in an ASTM standard, ASTM C1786 , Specification for Segmental Precast Reinforced Concrete Box Sections for Culverts, Storm Drains and Sewers Designed According to AASHTO LRFD. The American Association of State Highway and…, Technical Contact:, Josiah W. Beakley, American Concrete Pipe Association, Irving, Texas, tel +1.972.894.2906; jbeakley@concrete-pipe.org, ASTM Staff Contact:, Diane Lake, tel +1.610.832.9661; dlake@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9745
-
A proposed new ASTM International standard will aid in understanding thermal transport properties, an important component in optimizing the energy efficiency of building materials and improving thermal design in electronics, fuel cells and batteries. The test described in ASTM WK46204, Test Method for Determination of Thermal Conductivity and Thermal Diffusivity of Solids and Fluids Using the…, ASTM Committee E37 Next Meeting:, Aug. 29, University of Delaware Center for Composite Materials, Newark, Del., Technical Contact:, Mattias Gustavsson, Ph.D., Hot Disk AB, Gothenburg, Sweden, Phone: +46-31-411-410; mattias.gustavsson@hotdiskinstruments.com , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9629
-
Rotational viscometry is an easily used tool for determining the viscosity of fluids, including paints, petroleum products and polymer solutions. While standards often make use of rotational viscometry, a procedure for calibrating or validating the measurement is not always part of the standard, which could lead to results that differ from one laboratory to another. A proposed user viscosity…, ASTM Committee E37 Next Meeting:, March 14, 2014, ASTM International Headquarters, West Conshohocken, Pa., Technical Contact:, Roger Blaine, Corvallis, Ore., Phone: 302-559-6827; roger.l.blaine@gmail.com, ASTM Staff Contact:, Tom O'Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9493
-
Since 2009, the National Fire Protection Association has required arc rated gloves in its NFPA70E, Standard for Electrical Safety in the Workplace. A new ASTM standard will now provide arc rating thermal protective values for gloves, which will allow more gloves to be used inside an arc flash zone when there is no shock hazard. The new standard, ASTM F2675/F2675M , Test Method for Determining Arc…, ASTM Committee F18 Next Meeting:, Oct. 20-23, 2013, Charleston, S.C., Technical Contact:, Hugh Hoagland, ArcWear, Louisville, Ky., Phone: 502-832-9737; hugh@arcwear.com , ASTM Staff Contact:, Kevin Shanahan, Phone: 610-832-9737, kshanahan@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9469
-
Since the late 1970s, precast box sections have become an important component in the construction of culverts, storm drains and sewers, but there has not been a comprehensive standard for the installation of such sections. A new ASTM International standard fills this gap. ASTM C1675, Practice for Installation of Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains and…, Technical Contact:, Roman Selig, Hamilton Kent LLC, Birmingham, Ala., Phone: 205-910-0690; roman.selig@hamiltonkent.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9243
-
Load and resistance factor design methodology developed by the American Association of State Highway and Transportation Officials plays a key role in a proposed ASTM standard on the design of culverts and storm drains. ASTM WK38166 , Specification for Manufacture of Precast Reinforced Concrete Three-Sided Structures for Culverts and Storm Drains Designed According to AASHTO LRFD, is being…, Technical Contact:, Balaram K. Singh, P.E., Michigan Department of Transportation, Lansing, Mich., Phone: 517-335-2174; singhb@michigan.gov, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact, : Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9311
-
A proposed new standard being developed by ASTM International Committee F18 on Electrical Protective Equipment for Workers will provide guidance to assist in the required testing of live-line tools. ASTM WK33590 , Guide for In-Service Inspection, Maintenance and Electrical Testing of Insulating Tools (Fiberglass-Reinforced Plastic (FPR) and Wooden Live-Line Tools), is under the jurisdiction of…
-
Rheologists are encouraged to join in the development of a proposed new practice that will help standardize calibration of rotational rheometers to obtain accurate normal force measurements. ASTM WK33687 , Practice for Normal Force Calibration for Rotational Rheometers, is being developed by Subcommittee E37.08 on Rheology , part of ASTM International Committee E37 on Thermal Measurements . The…, ASTM Committee E37 Next Meeting:, Aug. 10-11, in conjunction with the North American Thermal Analysis Society Annual Conference, Des Moines, Iowa, Technical Contact:, Kenneth Aniunioh, Shimadzu Scientific Instruments, Laurel, Md., Phone: 864-633-7690; kenebaano@yahoo.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8923