Search
Advanced search
Filter by category
Filter by committee
Search results
-
Since the late 1970s, precast box sections have become an important component in the construction of culverts, storm drains and sewers, but there has not been a comprehensive standard for the installation of such sections. A new ASTM International standard fills this gap. ASTM C1675, Practice for Installation of Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains and…, Technical Contact:, Roman Selig, Hamilton Kent LLC, Birmingham, Ala., Phone: 205-910-0690; roman.selig@hamiltonkent.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9243
-
Load and resistance factor design methodology developed by the American Association of State Highway and Transportation Officials plays a key role in a proposed ASTM standard on the design of culverts and storm drains. ASTM WK38166 , Specification for Manufacture of Precast Reinforced Concrete Three-Sided Structures for Culverts and Storm Drains Designed According to AASHTO LRFD, is being…, Technical Contact:, Balaram K. Singh, P.E., Michigan Department of Transportation, Lansing, Mich., Phone: 517-335-2174; singhb@michigan.gov, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact, : Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9311
-
ASTM International, in support of efforts stemming from the Part 23 Reorganization Aviation Rulemaking Committee (ARC), will host an organizational meeting for the establishment of a new ASTM standards activity on general aviation (GA) airworthiness design standards. The meeting will be held Sept. 17, from 1:00 p.m. to 4:00 p.m. EST, at the Aircraft Electronics Association headquarters in Lee’s…, Next Meeting:, Sept. 17 at AEA headquarters and Oct. 26 in Atlanta, Ga., ASTM Staff Contact:, Christine DeJong, Phone: 610-832-9736; cdejong@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9277
-
A proposed new ASTM International standard will allow for a rapid and highly repeatable determination of chlorine in coal and coke through X-ray fluorescence spectroscopy. ASTM WK34943 , Test Method for Chlorine in Coal and Coke by XRF, is being developed by Subcommittee D05.29 on Major Elements in Ash and Trace Elements of Coal , which is part of ASTM International Committee D05 on Coal and Coke…, ASTM Committee D05 Next Meeting:, May 13-15, 2012, ASTM Headquarters, West Conshohocken, Pa., Technical Contact:, Colin Campbell, SaskPower, Regina, Saskatchewan, Canada, Phone: 306-566-2292; ccampbell@saskpower.com, ASTM Staff Contact:, Scott Orthey, Phone: 610-832-9730; sorthey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9110
-
A proposed new standard on determining the total amount of fluorine and chlorine in coal and coke will be useful to those working with power plant boilers as well as by those in government and industry who are trying to model the release of anions into the environment. The proposed new standard, ASTM WK33343 , Test Method for Total Fluorine and Chlorine in Coal, Coke and their Residues by…
-
New ASTM Vitrinite Reflectance Standard Will Aid in Prediction of Undiscovered Hydrocarbon ResourcesA new ASTM International standard for measuring the reflectance of vitrinite in sedimentary rocks will help improve predictions of the location, quantity and quality of undiscovered hydrocarbon resources. ASTM D7708 , Test Method for Microscopical Determination of the Reflectance of Vitrinite Dispersed in Sedimentary Rocks, was developed by Subcommittee D05.28 on Petrographic Analysis of Coal and…, ASTM Committee D05 Next Meeting:, Oct. 30-Nov. 2, 2011, October Committee Week, Tampa, Fla., Technical Contact:, Paul C. Hackley, U.S. Geological Survey, Reston, Va., Phone: 703-648-6458; phackley@usgs.gov, ASTM Staff Contact:, Scott Orthey, Phone: 610-832-9730; sorthey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8881
-
Natural gas from unconventional sources such as coal beds has become a common target of exploration. Now, a new ASTM standard is the first to describe a method for determining the gas content of coal from such sources by desorption, using samples obtained by surface drilling. ASTM D7569 , Practice for Determination of Gas Content of Coal - Direct Desorption Method, was developed by Subcommittee…, ASTM Committee D05 Next Meeting:, May 15-18, 2011, May Committee Week, Anaheim, Calif., Technical Contact:, Peter Warwick, U.S. Geological Survey, Reston, Va., Phone: 703-648-6469; pwarwick@usgs.gov, ASTM Staff Contact:, Scott Orthey, Phone: 610-832-9730; sorthey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8749
-
Moisture, volatile matter and ash are three of the primary parameters used for assessing the quality of coal. A new ASTM standard that covers the use of a macro thermogravimetric analyzer for the determination of moisture, volatile matter and ash in analysis samples of coal and coke has recently been approved by ASTM International Committee D05 on Coal and Coke. ASTM D7582 , Test Methods for…, ASTM Committee D05 Next Meeting:, May 16-19, May committee week, St. Louis, Mo., Technical Contact:, John T. Riley, Ph.D., Western Kentucky University, Bowling Green, Ky., Phone: 270-842-2757; brgrileys@insightbb.com, ASTM Staff Contact:, Scott Orthey, Phone: 610-832-9730; sorthey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8 508/Feb2010
-
The
-
ASTM International Committee C13 on Concrete Pipe has approved a new standard that covers flexible joints for concrete box sections using rubber gaskets for leak resistant joints. Subcommittee C13.08 on Joints for Precast Concrete Structures developed ASTM C1677 , Specification for Joints for Concrete Box, Using Rubber Gaskets. “This specification will provide a uniform minimum level of…