Search
Advanced search
Filter by category
Filter by committee
Search results
-
Stormwater hydrodynamic systems are used to remove settable solids that could cause contamination from stormwater runoff. A proposed new ASTM International standard will be used to specify test material with a common target particle size distribution for use in testing HDS systems. The proposed new standard, ASTM WK39909 , Specification for Surrogate Test Solids for Measuring Performance of…, ASTM Committee C27 Next Meeting:, Dec. 10-11, 2013, December Committee Week, Jacksonville, Fla., Technical Contact:, Adam A. Stevens, CONTECH Engineered Solutions, Scarborough, Maine, Phone: 207-885-9740; stevensa@contech-cpi.com, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9323
-
Since the late 1970s, precast box sections have become an important component in the construction of culverts, storm drains and sewers, but there has not been a comprehensive standard for the installation of such sections. A new ASTM International standard fills this gap. ASTM C1675, Practice for Installation of Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains and…, Technical Contact:, Roman Selig, Hamilton Kent LLC, Birmingham, Ala., Phone: 205-910-0690; roman.selig@hamiltonkent.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9243
-
Load and resistance factor design methodology developed by the American Association of State Highway and Transportation Officials plays a key role in a proposed ASTM standard on the design of culverts and storm drains. ASTM WK38166 , Specification for Manufacture of Precast Reinforced Concrete Three-Sided Structures for Culverts and Storm Drains Designed According to AASHTO LRFD, is being…, Technical Contact:, Balaram K. Singh, P.E., Michigan Department of Transportation, Lansing, Mich., Phone: 517-335-2174; singhb@michigan.gov, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact, : Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9311
-
While there are many commercially available stormwater treatment products currently on the market, there is no universal testing standard that would allow the performance of these products to be accurately compared. A proposed new ASTM International standard will fill this need, providing a testing method for stormwater treatment products that use filtration as a primary treatment process. ASTM…
-
A watertight septic system ensures its integrity, and demonstrating that integrity is important because such systems have over time become more complex, expensive and critical to both system owners and to the environment. A new ASTM International standard fills a need for an in-field installation test for septic systems. The new standard, ASTM C1719 , Test Method for Installed Precast Concrete…, ASTM Committee C27 Next Meeting:, Dec. 6-7, 2011, December Committee Week, Tampa, Fla., Technical Contact:, Michael R. Miller, Press-Seal Gasket Corp., Fort Wayne, Ind., Phone: 260-918-1626; mmiler@press-seal.com, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9008
-
ASTM International Committee C13 on Concrete Pipe has approved a new standard that covers flexible joints for concrete box sections using rubber gaskets for leak resistant joints. Subcommittee C13.08 on Joints for Precast Concrete Structures developed ASTM C1677 , Specification for Joints for Concrete Box, Using Rubber Gaskets. “This specification will provide a uniform minimum level of…
-
Responding to an increasing level of interest from engineers, regulators and communities, ASTM International Committee C27 on Precast Concrete Products has formed new Subcommittee C27.70 on Precast Concrete Products for Stormwater Management. “New environmental regulations, as well as vastly improved methods of meeting these, have created many new products and practices for stormwater management…
-
Although alkali resistant glass fibers have been commercially available for more than 30 years, there has not been an official standard that clearly defines what is required to make glass fibers resistant to alkali attack without the need for protective coatings. ASTM International Committee C27 on Precast Concrete Products has recently developed such a standard, C 1666/C 1666M , Specification…
-
Ineffective removal of grease from restaurants poses a variety of serious environmental problems. Large quantities of grease in public sanitary sewer systems can cause stoppages of piping networks and create costly and time-consuming problems at treatment plants. Sewer backups resulting from grease can also create health hazards when raw sewage backs up into homes or businesses. While grease…
-
ASTM International Committee F16 on Fasteners has recently approved an important new standard that deals with coated threaded fasteners and washers by hot-dip zinc galvanizing. The standard, F 2329, Specification for Zinc Coating, Hot-Dip, Requirements for Application to Carbon and Alloy Steel Bolts, Screws, Washers, Nuts and Special Threaded Fasteners, is under the jurisdiction of Subcommittee…