Since the late 1970s, precast box sections have become an important component in the construction of culverts, storm drains and sewers, but there has not been a comprehensive standard for the installation of such sections. A new ASTM International standard fills this gap. ASTM C1675, Practice for Installation of Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains and…, Technical Contact:, Roman Selig, Hamilton Kent LLC, Birmingham, Ala., Phone: 205-910-0690; roman.selig@hamiltonkent.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9243
-
Load and resistance factor design methodology developed by the American Association of State Highway and Transportation Officials plays a key role in a proposed ASTM standard on the design of culverts and storm drains. ASTM WK38166 , Specification for Manufacture of Precast Reinforced Concrete Three-Sided Structures for Culverts and Storm Drains Designed According to AASHTO LRFD, is being…, Technical Contact:, Balaram K. Singh, P.E., Michigan Department of Transportation, Lansing, Mich., Phone: 517-335-2174; singhb@michigan.gov, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact, : Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9311
-
Sealant manufacturers will use a new ASTM International standard to evaluate new products and changes to these products due to exposure to weather. The new standard, ASTM C1735 , Test Method for Measuring the Time Dependent Modulus of Sealants Using Stress Relaxation, is under the jurisdiction of Subcommittee C24.20 on General Test Methods , part of ASTM International Committee C24 on Building…, ASTM Committee C24 Next Meeting:, Jan. 8-10, 2012, Ft. Lauderdale, Fla., Technical Contact:, Christopher C. White, Ph.D., National Institute of Standards and Technology, Gaithersburg, Md., Phone: 301-975-6016; christopher.white@nist.gov, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9005
-
The
-
ASTM International Committee C13 on Concrete Pipe has approved a new standard that covers flexible joints for concrete box sections using rubber gaskets for leak resistant joints. Subcommittee C13.08 on Joints for Precast Concrete Structures developed ASTM C1677 , Specification for Joints for Concrete Box, Using Rubber Gaskets. “This specification will provide a uniform minimum level of…
-
ASTM International Committee D27 on Electrical Insulating Liquids and Gases is continuing its work on standards for natural esters with the development of a proposed new standard, WK21616 , Test Method for Oxidation Induction Time of Natural Ester Insulating Fluids by Pressure (PDSC) or Regular Differential Scanning Calorimetry (DSC). The proposed standard was submitted under the jurisdiction of…
-
The use of rolling devices can provide a means to evaluate the adhesion of weather seals, for quality control in new installations, general evaluation of existing installations, and the investigation of water and air leakage through building enclosures. In order to better facilitate the use of rolling devices, ASTM International Committee C24 on Building Seals and Sealants is developing a…
-
ASTM International Committee C24 on Building Seals and Sealants invites interested parties to participate in the development of a proposed new standard that will use photographs to illustrate various types of sealant failures. WK11731 , Guide for Diagnosing Sealant Failure by Comparison to Reference Photographs, is under the jurisdiction of Subcommittee C24.10 on Specifications, Guides and…
-
Dried blood represents the greatest challenge to cleaning surgical instruments. To meet this challenge, ASTM International Committee D12 on Soaps and Other Detergents has developed a new standard, D 7225 , Guide for Blood Cleaning Efficiency of Detergents and Washer-Disinfectors. The new guide is under the jurisdiction of Subcommittee D12.16 on Hard Surface Cleaning. Water-soluble components of…
-
During the past five years, certain insulating oils have been found to contain corrosive sulfur that can produce copper sulfide deposits as a function of time and temperature in operating equipment. A proposed revision to ASTM standard D 1275, Test Method for Corrosive Sulfur in Electrical Insulating Oils, will provide a means to certify that new or in service oils either contain or do not…