Since the late 1970s, precast box sections have become an important component in the construction of culverts, storm drains and sewers, but there has not been a comprehensive standard for the installation of such sections. A new ASTM International standard fills this gap. ASTM C1675, Practice for Installation of Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains and…, Technical Contact:, Roman Selig, Hamilton Kent LLC, Birmingham, Ala., Phone: 205-910-0690; roman.selig@hamiltonkent.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9243
-
Load and resistance factor design methodology developed by the American Association of State Highway and Transportation Officials plays a key role in a proposed ASTM standard on the design of culverts and storm drains. ASTM WK38166 , Specification for Manufacture of Precast Reinforced Concrete Three-Sided Structures for Culverts and Storm Drains Designed According to AASHTO LRFD, is being…, Technical Contact:, Balaram K. Singh, P.E., Michigan Department of Transportation, Lansing, Mich., Phone: 517-335-2174; singhb@michigan.gov, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact, : Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9311
-
ASTM International Committee F02 on Flexible Barrier Packaging will hold its next meeting on Sept. 26-27, 2012, at the Hotel Rey Juan Carlos I in Barcelona, Spain. At this meeting, participants will have the opportunity to contribute to the development and revision of a number of standards important to the use and evaluation of flexible barrier packaging. One of the highlights of the meeting will…, Future Trends in Permeation Measurements, , presented by Franz Sturm, Lipke •, U.S. FDA Perspective: The Use of Standards in Premarket Submissions and Auditing the Medical Device Packaging Process, , presented by Pat Weixel, U.S. Food and Drug Administration •, Microbial Barrier Test Methods for Porous Sterile Barrier Materials, , presented by Thierry Wagner, DuPont Medical and Pharmaceutical Protection •, Toward a Package Durability Predictive Model, , presented by Henk Blom, Rollprint Packaging Products •, Package Integrity: Methods of Detection, , presented by Wendy Mach, Nelson Laboratories •, Use of Design Guide F2097 and U.S. FDA Recognition, , Hal Miller, PACE Solutions LLC •, Sterile Medical Device Package Performance Testing and the Nebulous Effect of Vibration in Transit, , presented by Pat Nolan, DDL •, ASTM International: ASTM Mechanics and Overview, , presented by Diane Trinsey, ASTM Committee F02 staff manager All are welcome to attend. Registration and meeting information, including abstracts describing the presentations shown above, can be found at www.astm.org/COMMIT/F02/Barcelona_Meeting_info . Committee F02 develops standards on barrier materials, their properties and package design, development and production. Typical flexible barrier…, ASTM Committee F02 Next Meeting:, Sept. 26-27, 2012, Barcelona, Spain, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9289
-
Sealant manufacturers will use a new ASTM International standard to evaluate new products and changes to these products due to exposure to weather. The new standard, ASTM C1735 , Test Method for Measuring the Time Dependent Modulus of Sealants Using Stress Relaxation, is under the jurisdiction of Subcommittee C24.20 on General Test Methods , part of ASTM International Committee C24 on Building…, ASTM Committee C24 Next Meeting:, Jan. 8-10, 2012, Ft. Lauderdale, Fla., Technical Contact:, Christopher C. White, Ph.D., National Institute of Standards and Technology, Gaithersburg, Md., Phone: 301-975-6016; christopher.white@nist.gov, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9005
-
ASTM International Committee C13 on Concrete Pipe has approved a new standard that covers flexible joints for concrete box sections using rubber gaskets for leak resistant joints. Subcommittee C13.08 on Joints for Precast Concrete Structures developed ASTM C1677 , Specification for Joints for Concrete Box, Using Rubber Gaskets. “This specification will provide a uniform minimum level of…
-
A new ASTM International standard will have applications in a variety of factories, on artificial turfs and playing surfaces, and even in the classroom. The new standard, G194 , Test Method for Measuring Rolling Friction Characteristics of a Spherical Shape on a Flat Horizontal Surface, was developed by Subcommittee G02.50 on Friction, part of ASTM International Committee G02 on Wear and Erosion…
-
The use of rolling devices can provide a means to evaluate the adhesion of weather seals, for quality control in new installations, general evaluation of existing installations, and the investigation of water and air leakage through building enclosures. In order to better facilitate the use of rolling devices, ASTM International Committee C24 on Building Seals and Sealants is developing a…
-
Testing the oxygen permeation of packaging material is important for the suppliers of various barrier materials, as well as users of these materials in the food, pharmaceutical and consumer product companies, universities, research organizations and other industries. This kind of testing is covered in a new ASTM International standard approved by Committee F02 on Flexible Barrier Packaging, F2622…
-
An ASTM International task group on battery separator materials is currently working on the latest in a series of standards being developed for alkaline battery separators. The proposed new standard, WK13587 , Test Methods for Sampling and Testing Materials That Are Used for Alkaline Battery Separators, is under the jurisdiction of Subcommittee D09.19 on Dielectric Sheet and Roll Products, which…
-
Sterilized medical devices are indispensable to doctors and surgeons around the world. Peel pouches, otherwise known as preformed sterile barrier systems, are used to keep these devices sterile during all physical handling. These pouches can be made with a wide variety of material and are produced by many different suppliers, but the trait all pouches must share is the ability to protect devices…