Search
Advanced search
Filter by category
Filter by committee
Search results
-
A new ASTM International standard will support the sustainability and resiliency of concrete pipes that are reinforced by synthetic fibers. The new standard (soon to be approved as C1818, Specification for Rigid Synthetic Fiber Reinforced Concrete Culvert, Storm Drain and Sewer Pipe) describes a strong and durable option that can be used for underground piping. Pipes in this new standard are used…, ASTM Committee C13 on Concrete Pipe Next Meeting:, Nov. 15-18, 2015, November Committee Week, Tampa, Fla., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Ali Abolmaali, University of Texas, Arlington, Texas, tel +1.817.272.3877; abolmaail@uta.edu, ASTM Staff Contact:, Diane Lake, tel +1.610.832.9661; dlake@astm.org Release #9940
-
Keeping birds away from potentially fatal encounters with building exteriors is the purpose of a proposed new ASTM International standard, ASTM WK47853 , Test Method for Bird Collision Deterrence Material Threat Factor. It is possible that as many as a billion birds are killed every year after colliding with glass on buildings, including many single-family homes — and this is in the United States…, ASTM Committee C14 Next Meeting:, April 14, 2015, Moorestown, N.J., Technical Contact:, Stefan Knust, Ennead Architects, New York, New York, tel +1.212.807.7171; sknust@ennead.com, ASTM Staff Contact:, Thomas O’Toole, tel +1.610.832.9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9767
-
Precast reinforced concrete box sections are proving to be a versatile means for the development of infrastructure. The use of segmental box sections is now covered in an ASTM standard, ASTM C1786 , Specification for Segmental Precast Reinforced Concrete Box Sections for Culverts, Storm Drains and Sewers Designed According to AASHTO LRFD. The American Association of State Highway and…, Technical Contact:, Josiah W. Beakley, American Concrete Pipe Association, Irving, Texas, tel +1.972.894.2906; jbeakley@concrete-pipe.org, ASTM Staff Contact:, Diane Lake, tel +1.610.832.9661; dlake@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9745
-
Activated carbon is processed to have small, low-volume pores that increase the surface area available for adsorption. It has applications in the medical, environmental and energy realms, among others. Since 1962, ASTM International Committee D28 on Activated Carbon has developed standards that play a pre-eminent role in how activated carbon is used. A D28 subcommittee, D28.02 on Liquid Phase…, WK47401, Xylenol Orange Dye, The xylenol orange dye test is a way to determine the relative adsorption rate of unused or reactivated carbons by adsorption of xylenol orange from aqueous solution. This is an important means for deciding which type of activated carbon to use to a specific water treatment application. “Activated carbon performance can roughly be defined as a combination of the ability to adsorb a particular…, WK47421, Particle Size Distribution, Mercury flue gas, home water filters and potable water treatment are the main applications in which powdered and fine mesh carbons are used. A proposed new test method will describe how a laser light scattering technique can determine the particle size distribution of fine mesh activated carbon. ASTM member Neal Megonnell, vice president, sales and marketing, Haycarb USA, says the proposed test…, ASTM Committee D28 Next Meeting:, April 27, April Committee Week, Anaheim, Calif., Technical Contact:, (WK47401) Adam Redding, Ph.D., Evoqua Water Technologies LLC, Northwest, Pa., tel +1.724.719.0805; adam.redding@evoqua.com and (WK47421) Neal E. Megonnell, Haycarb USA, Pittsburgh, Pa., tel +1.412.709.7487; neal@haycarbusa.com, ASTM Staff Contact:, Kelly Paul, tel +1.610.832.9745; kpaul@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9731
-
Since the late 1970s, precast box sections have become an important component in the construction of culverts, storm drains and sewers, but there has not been a comprehensive standard for the installation of such sections. A new ASTM International standard fills this gap. ASTM C1675, Practice for Installation of Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains and…, Technical Contact:, Roman Selig, Hamilton Kent LLC, Birmingham, Ala., Phone: 205-910-0690; roman.selig@hamiltonkent.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9243
-
Load and resistance factor design methodology developed by the American Association of State Highway and Transportation Officials plays a key role in a proposed ASTM standard on the design of culverts and storm drains. ASTM WK38166 , Specification for Manufacture of Precast Reinforced Concrete Three-Sided Structures for Culverts and Storm Drains Designed According to AASHTO LRFD, is being…, Technical Contact:, Balaram K. Singh, P.E., Michigan Department of Transportation, Lansing, Mich., Phone: 517-335-2174; singhb@michigan.gov, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact, : Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9311
-
ASTM E2369 Provides Means for Healthcare Workers to Collect and Transfer Patient Data The Office of the National Coordinator for Health Information Technology (ONC), part of the United States Department of Health and Human Services, has included an ASTM International standard as part of its formal certification criteria for electronic health record (EHR) technologies. The standard, ASTM E2369…
-
An ASTM International standard used for effective and timely electronic messaging of health care records has now been adopted as a standard for structured summary health record exchange included in new regulations associated with the Health Information Technology for Economic and Clinical Health Act provision of the American Recovery and Reinvestment Act of 2009 (ARRA/HITECH). ASTM E2369 ,…, Technical Contact:, Dr. David C. Kibbe, The Kibbe Group L.L.C., Pittsboro, N.C. Phone: 913-205-7968; kibbedavid@mac.com, ASTM Staff Contact:, Dan Smith, Staff Manager , Phone: 610-832-9727; dsmith@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8451/Jan2010
-
ASTM International Committee C13 on Concrete Pipe has approved a new standard that covers flexible joints for concrete box sections using rubber gaskets for leak resistant joints. Subcommittee C13.08 on Joints for Precast Concrete Structures developed ASTM C1677 , Specification for Joints for Concrete Box, Using Rubber Gaskets. “This specification will provide a uniform minimum level of…
-
Mercury emissions from flue gases in coal-fired power plants are a large source of atmospheric mercury in the United States, but no standard for determination of mercury adsorption currently exists. One promising method of controlling these emissions involves the injection of powdered activated carbon into the flue gas. A proposed new ASTM International standard would evaluate the performance of…