Since 2009, the National Fire Protection Association has required arc rated gloves in its NFPA70E, Standard for Electrical Safety in the Workplace. A new ASTM standard will now provide arc rating thermal protective values for gloves, which will allow more gloves to be used inside an arc flash zone when there is no shock hazard. The new standard, ASTM F2675/F2675M , Test Method for Determining Arc…, ASTM Committee F18 Next Meeting:, Oct. 20-23, 2013, Charleston, S.C., Technical Contact:, Hugh Hoagland, ArcWear, Louisville, Ky., Phone: 502-832-9737; hugh@arcwear.com , ASTM Staff Contact:, Kevin Shanahan, Phone: 610-832-9737, kshanahan@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9469
-
A proposed new ASTM International standard will be helpful in selecting glass or glazing that has a proper communication transmittance rate for the location in which it is being used. ASTM WK41897 , Test Method for EMI Transmittance and Shielding Rating for Glazing Infill, is being developed by Subcommittee F12.10 on Systems Products and Services , part of ASTM International Committee F12 on…, ASTM Committee F12 Next Meeting:, Oct. 21-21, 2013, October Committee Week, Jacksonville, Fla., Technical Contact:, Julia Schimmelpenningh, Eastman Chemical Co., Springfield, Mass., Phone: 413-730-3413; jcschi@eastman.com , ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9421
-
Since the late 1970s, precast box sections have become an important component in the construction of culverts, storm drains and sewers, but there has not been a comprehensive standard for the installation of such sections. A new ASTM International standard fills this gap. ASTM C1675, Practice for Installation of Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains and…, Technical Contact:, Roman Selig, Hamilton Kent LLC, Birmingham, Ala., Phone: 205-910-0690; roman.selig@hamiltonkent.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9243
-
Load and resistance factor design methodology developed by the American Association of State Highway and Transportation Officials plays a key role in a proposed ASTM standard on the design of culverts and storm drains. ASTM WK38166 , Specification for Manufacture of Precast Reinforced Concrete Three-Sided Structures for Culverts and Storm Drains Designed According to AASHTO LRFD, is being…, Technical Contact:, Balaram K. Singh, P.E., Michigan Department of Transportation, Lansing, Mich., Phone: 517-335-2174; singhb@michigan.gov, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact, : Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9311
-
It happens all too often: a driver suddenly loses control of a car, sending it into a storefront or other pedestrian area. Property damage and serious injuries, sometimes fatal, can result from these accidents. In an effort to minimize the damage caused by such crashes, ASTM International Committee F12 on Security Systems and Equipment is developing a proposed new standard, ASTM WK13074 , Test…, ASTM Committee F12 Next Meeting:, Oct. 22-24, 2012, October Committee Week, Atlanta, Ga., Technical Contacts:, Rob Reiter, Storefront Safety Consultant, Phone: 909-964-2906; r ob.reiter.pp@gmail.com ; Dean Alberson, Texas Transportation Institute, Texas A&M University, Phone: 979-458-3874; d-alberson@tamu.edu, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindler@astm.org R elease #9263
-
A proposed new standard being developed by ASTM International Committee F18 on Electrical Protective Equipment for Workers will provide guidance to assist in the required testing of live-line tools. ASTM WK33590 , Guide for In-Service Inspection, Maintenance and Electrical Testing of Insulating Tools (Fiberglass-Reinforced Plastic (FPR) and Wooden Live-Line Tools), is under the jurisdiction of…
-
ASTM International Committee F12 on Security Systems and Equipment invites all interested parties to participate in the current revision of ASTM F967 , Practice for Security Engineering Symbols. The standard is under the jurisdiction of Subcommittee F12.10 on Systems, Products and Services. According to Ed Conrath, senior principal, Protection Engineering Consultants, and F12 committee chairman,…
-
“Bumping” is a process that can allow virtually anyone to covertly operate a pin tumbler lock. A long-held locksmith secret, bumping has become more well known as videos describing the process of making and using a bump key have surfaced on the Internet. Potential intruders can use the bumping process to break into homes and other buildings while leaving the impression that something must have…
-
ASTM International Committee C13 on Concrete Pipe has approved a new standard that covers flexible joints for concrete box sections using rubber gaskets for leak resistant joints. Subcommittee C13.08 on Joints for Precast Concrete Structures developed ASTM C1677 , Specification for Joints for Concrete Box, Using Rubber Gaskets. “This specification will provide a uniform minimum level of…
-
Arc protective blankets are used in many electrical applications to protect workers who are stationed near energized electrical parts. While these blankets have been used for years, there have been no testing criteria for their evaluation. A new ASTM International standard will be used to determine the effectiveness of arc protective blankets in suppressing the combined effect of an arc flash and…