Search
Advanced search
Filter by category
Filter by committee
Search results
-
A new ASTM International standard will support the sustainability and resiliency of concrete pipes that are reinforced by synthetic fibers. The new standard (soon to be approved as C1818, Specification for Rigid Synthetic Fiber Reinforced Concrete Culvert, Storm Drain and Sewer Pipe) describes a strong and durable option that can be used for underground piping. Pipes in this new standard are used…, ASTM Committee C13 on Concrete Pipe Next Meeting:, Nov. 15-18, 2015, November Committee Week, Tampa, Fla., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Ali Abolmaali, University of Texas, Arlington, Texas, tel +1.817.272.3877; abolmaail@uta.edu, ASTM Staff Contact:, Diane Lake, tel +1.610.832.9661; dlake@astm.org Release #9940
-
A new ASTM International standard will help oil spill responders evaluate the stability of water-in-oil mixtures. Specifically, the new standard (soon to be published as F3045, Test Method for the Evaluation of the Stability of Water-in-Oil Mixtures Formed from Crude Oil and Petroleum Products Mixed with Saline Water) provides a laboratory test method to determine the tendencies of emulsions and…, ASTM Committee F20 on Hazardous Substances and Oil Spill Response Next Meeting, : Oct. 25-26, 2016, October Committee Week, Orlando, Fla., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Mervin Fingas, Edmonton, Alberta, Canada, tel +1.780.989.6059; fingasmerv@shaw.ca , ASTM Staff Contact:, Jeffrey Adkins, tel +1.610.832.9738; jadkins@astm.org Release #9936
-
A proposed new ASTM standard will provide a lab test to determine how various types of oil will interact with water in oil spill situations. Information gleaned from such testing will ultimately lead to more effective oil spill recovery. All interested parties are welcome to join in the ongoing development of the standard ( WK41247 , Test Method for the Evaluation of the Stability of Water-in-Oil…, ASTM Committee F20 on Hazardous Substances and Oil Spill Response Next Meeting:, Oct. 27-28, 2015, October committee week, Tampa, Fla., Technical Contact:, Mervin Fingas, Edmonton, Alberta, Canada, tel +1.780.989.6059; fingasmerv@shaw.ca, ASTM Staff Contact:, Jeffrey Adkins, tel +1.610.832.9738; jadkins@astm.org, ASTM PR Contact:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org Release #9772
-
Precast reinforced concrete box sections are proving to be a versatile means for the development of infrastructure. The use of segmental box sections is now covered in an ASTM standard, ASTM C1786 , Specification for Segmental Precast Reinforced Concrete Box Sections for Culverts, Storm Drains and Sewers Designed According to AASHTO LRFD. The American Association of State Highway and…, Technical Contact:, Josiah W. Beakley, American Concrete Pipe Association, Irving, Texas, tel +1.972.894.2906; jbeakley@concrete-pipe.org, ASTM Staff Contact:, Diane Lake, tel +1.610.832.9661; dlake@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9745
-
The laboratory conditions test described in a new ASTM International standard will be used by manufacturers to determine the sustained air performance and exhaust emissions of a central vacuum cleaner. ASTM F2826 , Test Method for Evaluating the Sustained Air Performance and Exhaust Emissions of Central Vacuum Cleaning Units, was developed by Subcommittee F11.22 on Air Performance , part of ASTM…, ASTM Committee F11 Next Meeting:, May 5-7, 2014, May Committee Week, Toronto, Ontario, Canada, Technical Contact:, Darrell Nieschwitz, H-P Products Inc., Louisville, Ohio, Phone: 330-875-5556, ext. 2272; dnieschwitz@h-pproducts.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9584
-
A proposed new ASTM International standard will provide a laboratory conditions test for determining the sustained air performance and exhaust emissions of central vacuum cleaners. ASTM WK14392 , Test Method for Evaluating the Sustained Air Performance and Exhaust Emissions of Central Vacuum Cleaning Units, is being developed by Subcommittee F11.22 on Air Performance , part of ASTM International…, ASTM Committee F11 Next Meeting:, May 5-7, 2014, May Committee Week, Toronto, Ontario, Canada, Technical Contact, : Darrell Nieschwitz, H-P Products Inc., Louisville, Ohio, Phone: 330-875-5556, ext. 2272; dnieschwitz@h-pproducts.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9532
-
ASTM International Committee F11 on Vacuum Cleaners has formed a new task group to develop proposed standards for high efficiency particulate air filtration, typically known as HEPA. The task group, part of Subcommittee F11.23 on Filtration, will develop standards to clarify methodology and criteria used to define HEPA filtration for sealed vacuum cleaner systems and filter components used in…, ASTM Committee F11 Next Meeting:, May 20-22, 2013, May Committee Week, Indianapolis, Ind., Technical Contact:, Zoe Wilson, Bissell Homecare Inc., Grand Rapids, Mich., Phone: 616-735-5142; zoe.wilson@bissell.com , ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9338
-
Since the late 1970s, precast box sections have become an important component in the construction of culverts, storm drains and sewers, but there has not been a comprehensive standard for the installation of such sections. A new ASTM International standard fills this gap. ASTM C1675, Practice for Installation of Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains and…, Technical Contact:, Roman Selig, Hamilton Kent LLC, Birmingham, Ala., Phone: 205-910-0690; roman.selig@hamiltonkent.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9243
-
Load and resistance factor design methodology developed by the American Association of State Highway and Transportation Officials plays a key role in a proposed ASTM standard on the design of culverts and storm drains. ASTM WK38166 , Specification for Manufacture of Precast Reinforced Concrete Three-Sided Structures for Culverts and Storm Drains Designed According to AASHTO LRFD, is being…, Technical Contact:, Balaram K. Singh, P.E., Michigan Department of Transportation, Lansing, Mich., Phone: 517-335-2174; singhb@michigan.gov, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact, : Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9311
-
Coated fabric products used for oil spill response procedures can deteriorate when stored for long periods of time. A proposed new ASTM standard will provide a nondestructive test for stored equipment to be evaluated for continued suitability over time. ASTM WK37298 , Test Method for Determining Storage Life of Coated Fabric Products, is being developed by Subcommittee F20.11 on Control , part of…, ASTM Committee F20 Next Meeting:, Oct. 23-24, 2012, October Committee Week, Atlanta, Ga., Technical Contact:, Peter Lane, Applied Fabric Technologies Inc., Applied Fabric Technologies Inc., Morris Skimmers International LLC, Orchard Park, N.Y., Phone: 716-662-0632; lane@afti.com, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9310