A recently published ASTM International standard covers a new type of resilient flooring tile product based on a polyester binder. ASTM F2982 , Specification for Polyester Composition Floor Tile, was developed by Subcommittee F06.80 on Specifications , part of ASTM International Committee F06 on Resilient Floor Coverings . “ ASTM F2982 sets forth an explicit set of compositional and performance…, ASTM Committee F06 Next Meeting:, May 22-23, 2013, May Committee Week, Indianapolis, Ind., Technical Contact:, Thomas Erisman, Armstrong World Industries, Lancaster, Pa., Phone: 717-396-5354; tcerisman@armstrong.com, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9271
-
ASTM International Committee D15 on Engine Coolants has formed three new subcommittees: Subcommittees D15.22 on Non-Aqueous Coolants ; D15.25 on Diesel Exhaust Fluid ; and D15.30 on Industrial Heat Transfer Fluids . All interested parties are invited to join in the standards developing activities of these new subcommittees., D15.22, Non-Aqueous Coolants, While there has been an increased interest in non-aqueous coolants industry, there are no current ASTM standards in this area. D15.22 will begin to develop such standards. “The envisioned standards for non-aqueous coolants would be performance standards, rather than ingredient standards, to allow for formulations that are not currently proprietary,” says Jonathan T. Light, chief engineer, Evans…, D15.25, Diesel Exhaust Fluid, Diesel exhaust fluid, often referred to as DEF, is required by many diesel engine-powered vehicles delivered after January 2010. More recent environmental standards issued by the U.S. Environmental Protection Agency have created more stringent emissions standards for agricultural, construction and forestry equipment. DEF is used to reduce nitrogen oxide emissions, which allows original equipment…, D15.30, Industrial Heat Transfer Fluids, Members of D15 recognized that changes in the antifreeze industry, including new manufacturing technologies, improved inhibitor chemistries and recycling technologies, would likely be adapted to the facilities industry as a natural course of innovation. Because D15 has experience developing standards that are technically similar to the facilities heat transfer industry, it was deemed appropriate…, ASTM Committee D15 Next Meeting:, May 17-18, May Committee Week, Anaheim, Calif., Technical Contact:, (D15.22) Jonathan T. Light, Evans Cooling Systems Inc., Sharon, Conn., Phone: 860-435-2418; jtlight@comcast.net ; (D15.25) Edward Eaton Sr., Amalgatech, Phoenix, Ariz., Phone: 602-252-0280; edeaton@amalgatech.com ; (D15.30) John Panasewicz, Clear Choice Antifreeze, Henderson, Colo., Phone: 303-227-9900; johnp@clearchoiceantifreeze.com, ASTM Staff Contact:, Joe Koury, Phone: 610-832-9804; jkoury@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8837
-
Non-destructive moisture meters are now widely used in determining moisture levels in concrete, gypsum concrete and other types of floor slabs. A new ASTM International standard qualifies the types of meter suitable for this purpose and provides guidelines for how, where and when such moisture meters are used and what limitations exist. The new standard, ASTM F2659 , Guide for Preliminary…, ASTM Committee F06 Next Meeting:, Nov. 10-11, New Orleans, La., Technical Contact:, Sean Fallon, Dublin, Ireland, Phone: +011-353-1-285-1861; seanfallon@ireland.com, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #870/Oct2010
-
Several years ago, a housing boom followed by recovery from damage caused by Hurricane Katrina and other storms created a surge in the use of imported drywall in the United States, particularly in the southeastern area of the country. However, since then, there have been a number of complaints concerning corrosion and odors in homes in which some of this drywall was used. Interim guidance…
-
A series of proposed new standards being developed by ASTM International Committee D15 on Engine Coolants would remove technical barriers that currently prevent the cost-effective replacement of ethylene glycol with more environmentally friendly glycerin in antifreeze. The proposed standards are under the jurisdiction of Subcommittee D15.93 on Research and Long Range Planning. Natural glycerin is…
-
With heightened interest in issues involving corrosive gypsum board, the first draft of a proposed new standard on the subject, ASTM WK26072 , Practice for Evaluation of Buildings to Identify Corrosive Gypsum Board, was reviewed and edited at a task group meeting on Nov. 10 in Atlanta, Ga. The proposed new standard is under the jurisdiction of ASTM Subcommittee C11.01 on Specifications and Test…, ASTM Committee C11 Next Meeting:, May 17-19, 2010, St. Louis, Mo., Technical Contact:, Spiderman Mulholland, U.S. Building Consultants Inc., Gainesville, Fla., Phone: 352-505-6771; spiderman@usbcinc.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8414/Nov2009
-
At an ASTM International meeting held on Oct. 20 it was decided to initiate the formulation of a proposed new ASTM standard that will cover issues relating to drywall and indoor air quality. Representatives from various ASTM International committees, including C11 on Gypsum and Related Building Materials and Systems and E06 on Performance of Buildings attended the meeting, which was held during…
-
Special considerations need to be made for flooring in multi-purpose rooms, particularly those in child care buildings, elementary schools and long-term care facilities. ASTM International Committee F06 on Resilient Floor Coverings is currently developing a proposed new standard for such flooring. WK24836 , Specification for Active Area, Multipurpose Flooring, is under the jurisdiction of…
-
The use of non-metallic plaster bases (lath) is growing in the construction industry, and minimum consensus standards are being set for installation, test methods and performance requirements. A task group within Subcommittee C11.02 on Specifications and Test Methods for Accessories and Related Products is currently developing three lath standards: ASTM WK24554 , Test Method for Non-Metallic…
-
In response to changing emissions restrictions and consumer expectations, ASTM International Committee D15 on Engine Coolants is now developing a proposed new standard, WK16003 , Specification for Engine Coolant Grade 1,3-propanediol (PDO). This task group is under the jurisdiction of Subcommittee D15.07 on Specifications. Edward Eaton, D15 member and chief engineer, Amalgatech, says that as…