Search
Advanced search
Filter by category
Filter by committee
Search results
-
A watertight septic system ensures its integrity, and demonstrating that integrity is important because such systems have over time become more complex, expensive and critical to both system owners and to the environment. A new ASTM International standard fills a need for an in-field installation test for septic systems. The new standard, ASTM C1719 , Test Method for Installed Precast Concrete…, ASTM Committee C27 Next Meeting:, Dec. 6-7, 2011, December Committee Week, Tampa, Fla., Technical Contact:, Michael R. Miller, Press-Seal Gasket Corp., Fort Wayne, Ind., Phone: 260-918-1626; mmiler@press-seal.com, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9008
-
Once approved, a proposed new ASTM International standard will aid in the evaluation of high performance protective coatings for sewerage systems. The proposed standard will provide a test specific to these coatings. Subcommittee G01.05 on Laboratory Corrosion Tests is developing ASTM WK33537 , Practice for Operating the Severe Wastewater Analysis Testing Apparatus. G01.05 is under the…, ASTM Committee G01 Next Meeting:, Nov. 16-17, 2011, November Committee Week, Tampa, Fla., Technical Contact:, Vaughn O’Dea, Tnemec Co. Inc., Kansas City, MO, Phone: 816-519-2267; odea@tnemec.com, ASTM Staff Contact:, Jennifer Rodgers, Phone: 610-832-9694; jrodgers@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8977
-
While the use of internally cured concrete in construction is not new, there is now better understanding of the internal curing process and why IC using pre-wetted lightweight aggregate increases concrete durability and service life in an economical and practical way. However, there is not currently a standard for lightweight aggregates for internal curing. ASTM International Committee C09 on…
-
A new ASTM International standard will provide a method of testing corrosion-resistant fasteners and their performance in contact with treated wood. ASTM G198 , Test Method for Determining the Relative Corrosion Performance of Driven Fasteners in Contact with Treated Wood, was developed by Subcommittee G01.14 on Corrosion of Metals in Construction Materials , part of ASTM International Committee…
-
ASTM International Committee C09 on Concrete and Concrete Aggregates is currently developing a proposed standard that addresses bleed stability. ASTM WK28156 , Test Method for Bleed Stability of Cementitious Grout Under Static Pressure, is under the jurisdiction of ASTM International Subcommittee C09.41 on Hydraulic Cement Grouts. When cementitious grouts bleed, mixing water separates from the…, ASTM Committee C09 Next Meeting:, Dec. 6-8, December Committee Week, New Orleans, La., Technical Contact:, Fred Goodwin, BASF Construction Chemicals, Cleveland, Ohio, Phone: 216-839-7009; fred.goodwin@basf.com, ASTM Staff Contact:, Scott Orthey, Phone: 610-832-9730; sorthey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8648
-
Corrosion inhibitors are used extensively for pipelines in the oil and gas industry. Subcommittee G01.05 on Laboratory Corrosion Tests has been developing a series of standards on performance testing of corrosion inhibitors, including the most recently approved: ASTM G202 , Test Method for Using Atmospheric Pressure Rotating Cage. Subcommittee G01.05 is part of ASTM International Committee G01 on…
-
Members of ASTM Committees C09 on Concrete and Concrete Aggregates and C01 on Cement, as well as other interested parties, are invited to join new Subcommittee C09.50 on Risk Management for Alkali Aggregate Reactions. The new subcommittee will develop standards on the mitigation of deleterious alkali-aggregate reactions in concrete. To initiate the launch of C09.50, Committees C01 and C09 are the…
-
Subjects Include Aggregate Resistivity, Lightweight Aggregates, Methacrylate Bonding Systems and Semi-Adiabatic Calorimetry The following four proposed new standards are among those currently being developed by subcommittees under the jurisdiction of ASTM Committee C09 on Concrete and Concrete Aggregates. Subject matter covered by these standards includes aggregate resistivity, lightweight…
-
Localized corrosion, such as pitting, cracking or crevice corrosion, can be destructive to process equipment, but if it is detected early enough, potential damage can be minimized or avoided. A new ASTM International standard provides a means for electrochemical testing for corrosion. The new standard, G199 , Guide for Electrochemical Noise Measurement, was developed by Subcommittee G01.11 on…
-
ASTM Pervious Concrete Subcommittee Developing Proposed Standard for Sustainable Mixture ProportionsOnce approved, a proposed new ASTM standard will aid concrete producers in developing sustainable and durable mixture proportions for pervious concrete. The proposed new standard, WK23367 , Test Method for Evaluating the Surface Durability Potential of a Pervious Concrete Mixture, is being developed by Subcommittee C09.49 on Pervious Concrete, part of ASTM International Committee C09 on Concrete…