Search
Advanced search
Filter by category
Filter by committee
Search results
-
Stormwater hydrodynamic systems are used to remove settable solids that could cause contamination from stormwater runoff. A proposed new ASTM International standard will be used to specify test material with a common target particle size distribution for use in testing HDS systems. The proposed new standard, ASTM WK39909 , Specification for Surrogate Test Solids for Measuring Performance of…, ASTM Committee C27 Next Meeting:, Dec. 10-11, 2013, December Committee Week, Jacksonville, Fla., Technical Contact:, Adam A. Stevens, CONTECH Engineered Solutions, Scarborough, Maine, Phone: 207-885-9740; stevensa@contech-cpi.com, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9323
-
While there are many commercially available stormwater treatment products currently on the market, there is no universal testing standard that would allow the performance of these products to be accurately compared. A proposed new ASTM International standard will fill this need, providing a testing method for stormwater treatment products that use filtration as a primary treatment process. ASTM…
-
A proposed new ASTM standard will provide proper direction and ensure adequate documentation to aid in the interpretation, understanding and reduction of variance in test results for fiber-reinforced concrete. ASTM WK35250 , Practice for Fiber-Reinforced Concrete for Making and Curing Test Specimens in the Laboratory and Field, is now being developed by Subcommittee C09.42 on Fiber-Reinforced…
-
Formalizing a method for making a cylindrical specimen of roller-compacted concrete in a gyratory compactor is the primary purpose of a proposed new ASTM International standard. ASTM WK33682 , Test Method for Preparation, Compaction and Density Determination of Roller-Compacted Concrete Specimens by Means of the Superpave Gyratory Compactor, is being developed by Subcommittee C09.45 on Roller-…
-
A watertight septic system ensures its integrity, and demonstrating that integrity is important because such systems have over time become more complex, expensive and critical to both system owners and to the environment. A new ASTM International standard fills a need for an in-field installation test for septic systems. The new standard, ASTM C1719 , Test Method for Installed Precast Concrete…, ASTM Committee C27 Next Meeting:, Dec. 6-7, 2011, December Committee Week, Tampa, Fla., Technical Contact:, Michael R. Miller, Press-Seal Gasket Corp., Fort Wayne, Ind., Phone: 260-918-1626; mmiler@press-seal.com, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9008
-
While the use of internally cured concrete in construction is not new, there is now better understanding of the internal curing process and why IC using pre-wetted lightweight aggregate increases concrete durability and service life in an economical and practical way. However, there is not currently a standard for lightweight aggregates for internal curing. ASTM International Committee C09 on…
-
Rheologists are encouraged to join in the development of a proposed new practice that will help standardize calibration of rotational rheometers to obtain accurate normal force measurements. ASTM WK33687 , Practice for Normal Force Calibration for Rotational Rheometers, is being developed by Subcommittee E37.08 on Rheology , part of ASTM International Committee E37 on Thermal Measurements . The…, ASTM Committee E37 Next Meeting:, Aug. 10-11, in conjunction with the North American Thermal Analysis Society Annual Conference, Des Moines, Iowa, Technical Contact:, Kenneth Aniunioh, Shimadzu Scientific Instruments, Laurel, Md., Phone: 864-633-7690; kenebaano@yahoo.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8923
-
ASTM International Committee C09 on Concrete and Concrete Aggregates is currently developing a proposed standard that addresses bleed stability. ASTM WK28156 , Test Method for Bleed Stability of Cementitious Grout Under Static Pressure, is under the jurisdiction of ASTM International Subcommittee C09.41 on Hydraulic Cement Grouts. When cementitious grouts bleed, mixing water separates from the…, ASTM Committee C09 Next Meeting:, Dec. 6-8, December Committee Week, New Orleans, La., Technical Contact:, Fred Goodwin, BASF Construction Chemicals, Cleveland, Ohio, Phone: 216-839-7009; fred.goodwin@basf.com, ASTM Staff Contact:, Scott Orthey, Phone: 610-832-9730; sorthey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8648
-
Members of ASTM Committees C09 on Concrete and Concrete Aggregates and C01 on Cement, as well as other interested parties, are invited to join new Subcommittee C09.50 on Risk Management for Alkali Aggregate Reactions. The new subcommittee will develop standards on the mitigation of deleterious alkali-aggregate reactions in concrete. To initiate the launch of C09.50, Committees C01 and C09 are the…
-
The ASTM International Proficiency Testing Center is pleased to offer a 2010 Proficiency Testing Program on Thermal Analyses of Plastics (TAP) to laboratories who need a statistical quality assurance tool that will enable them to improve and maintain a high level of performance in conducting ASTM Differential Scanning Calorimetry (DSC), Oxidative-Induction Time (OIT) by Differential Scanning…, ASTM D3418, , Standard Test Method for Transition Temperatures and Enthalpies of Fusion and Crystallization of Polymers by Differential Scanning Calorimetry (DSC);, ASTM D3850, , Standard Test Method for Rapid Thermal Degradation of Solid Electrical Insulating Materials By Thermogravimetric Method (TGA); and, ASTM D3895, , Standard Test Method for Oxidative-Induction Time of Polyolefins by Differential Scanning Calorimetry. For each test trial, laboratory participants receive two sample materials along with interactive electronic data report forms and test instructions. Using the specified ASTM program tests, participating laboratories conduct the tests of their choice that they routinely run. Upon completion of…