Search
Advanced search
Filter by category
Filter by committee
Search results
-
ASTM International Subcommittee E34.50 on Health and Safety Standards for Metalworking Fluids has developed three new standards. Two of the recently approved ASTM standards cover aspects of water-miscible metalworking fluids, while the third concerns prevention of dermatitis in the wet metal removal fluid environment., Prevention of Dermatitis, Dermatitis is an inflammatory response of the skin to a chemical or physical agent. While redness, swelling and itching are typical signs of dermatitis, symptoms can be more severe as well. A new ASTM standard, ASTM E2693 , Practice for Prevention of Dermatitis in the Wet Metal Removal Fluid Environment, discusses dermatitis and its causes and presents a comprehensive approach to dermatitis…, Metalworking Fluids, Two new E34.50 standards address the detection of microbial contamination in metalworking fluids: ASTM E2657 , Test Method for Determination of Endotoxin Concentrations in Water-Miscible Metalworking Fluids, and ASTM E2694 , Test Method for Measurement of Adenosine Triphosphate in Water-Miscible Metalworking Fluids. Both ASTM E2657 and ASTM E2694 measure biological contamination in metalworking…, Participation Invited, The subcommittee is currently looking for participants for an interlaboratory study for ASTM E2657 and ASTM E2694 . “We plan to use a single set of MWF for both standards, so labs who are interested in either or both are welcome to participate,” says Passman. “A few labs will run both the ILS’s for both standards, while most will run one or the other.” Subcommittee E34.50 is part of ASTM…
-
A new ASTM International standard will have applications in a variety of factories, on artificial turfs and playing surfaces, and even in the classroom. The new standard, G194 , Test Method for Measuring Rolling Friction Characteristics of a Spherical Shape on a Flat Horizontal Surface, was developed by Subcommittee G02.50 on Friction, part of ASTM International Committee G02 on Wear and Erosion…
-
Testing the oxygen permeation of packaging material is important for the suppliers of various barrier materials, as well as users of these materials in the food, pharmaceutical and consumer product companies, universities, research organizations and other industries. This kind of testing is covered in a new ASTM International standard approved by Committee F02 on Flexible Barrier Packaging, F2622…
-
ASTM International Committee F03 on Gaskets has developed and approved a new standard that can be used to evaluate gasket materials covered by ASTM F104 , Classification System for Nonmetallic Gasket Materials. The new standard, F2716 , Practice for Comparison of Nonmetallic Flat Gaskets in High Pressure Saturated Steam, is under the jurisdiction of Subcommittee F03.10 on Composite Gaskets. ASTM…
-
A new ASTM International standard responds to a recent emphasis by regulatory agencies that firms manufacturing drug products demonstrate the efficacy of disinfectants used in controlled environments. The standard, ASTM E2614 , Guide for Evaluation of Cleanroom Disinfectants, was developed by Subcommittee E35.15 on Antimicrobial Agents, part of ASTM International Committee E35 on Pesticides and…
-
All interested parties in the glass industry are invited to participate in the development of a proposed new standard guide for the safe handling of annealed glass. The new standard will be developed by a task group within ASTM Committee E34 on Occupational Health and Safety. A small group from industry and OSHA met in Rossford, Ohio, in March to discuss this new activity. The task group plans to…
-
Information and product destruction services is a rapidly growing industry. In order to develop standards to serve the needs of this industry, ASTM International Committee E34 on Occupational Health and Safety has formed Subcommittee E34.25 on Mobile and Plant-Based Security Destruction Equipment Safety Requirements. All interested parties are invited to participate in the standards developing…
-
An important standard that is used to help protect the health of workers where there may be occupational exposure to quartz dust has recently been revised. ASTM standard E 1132 , Practice for Health Requirements Relating to Occupational Exposure to Respirable Crystalline Silica, was developed by Subcommittee E34.16 on Silicas, which is under the jurisdiction of Committee E34 on Occupational…
-
Sterilized medical devices are indispensable to doctors and surgeons around the world. Peel pouches, otherwise known as preformed sterile barrier systems, are used to keep these devices sterile during all physical handling. These pouches can be made with a wide variety of material and are produced by many different suppliers, but the trait all pouches must share is the ability to protect devices…
-
A new standard developed by ASTM International Committee E34 on Occupational Health and Safety will provide foundries with a comprehensive set of safety requirements. The standard, E 2349, Practice for Safety Requirements in Metal Casting Operations: Sand Preparation, Molding, and Core Marking; Melting and Pouring; and Cleaning and Finishing, is under the jurisdiction of Subcommittee E34.20 on…