The laboratory conditions test described in a new ASTM International standard will be used by manufacturers to determine the sustained air performance and exhaust emissions of a central vacuum cleaner. ASTM F2826 , Test Method for Evaluating the Sustained Air Performance and Exhaust Emissions of Central Vacuum Cleaning Units, was developed by Subcommittee F11.22 on Air Performance , part of ASTM…, ASTM Committee F11 Next Meeting:, May 5-7, 2014, May Committee Week, Toronto, Ontario, Canada, Technical Contact:, Darrell Nieschwitz, H-P Products Inc., Louisville, Ohio, Phone: 330-875-5556, ext. 2272; dnieschwitz@h-pproducts.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9584
-
A proposed new ASTM International standard will provide a laboratory conditions test for determining the sustained air performance and exhaust emissions of central vacuum cleaners. ASTM WK14392 , Test Method for Evaluating the Sustained Air Performance and Exhaust Emissions of Central Vacuum Cleaning Units, is being developed by Subcommittee F11.22 on Air Performance , part of ASTM International…, ASTM Committee F11 Next Meeting:, May 5-7, 2014, May Committee Week, Toronto, Ontario, Canada, Technical Contact, : Darrell Nieschwitz, H-P Products Inc., Louisville, Ohio, Phone: 330-875-5556, ext. 2272; dnieschwitz@h-pproducts.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9532
-
All interested parties are invited to participate in the standards developing activities of Subcommittee E07.11 on Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) , part of ASTM International Committee E07 on Nondestructive Testing . The subcommittee is focusing on developing standards that test the interoperability of DICONDE-compliant inspection equipment. DICONDE…, ASTM Committee E07 Next Meeting:, Jan. 26-30, 2014, Ft. Lauderdale, Fla, Technical Contact:, Patrick Howard, GE Aviation, Cincinnati, Ohio, Phone: 513-552-4646; patrick.howard@ge.com , ASTM Staff Contact:, Kathleen McClung, Phone: 610-832-9717; kmcclung@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9500
-
Rotational viscometry is an easily used tool for determining the viscosity of fluids, including paints, petroleum products and polymer solutions. While standards often make use of rotational viscometry, a procedure for calibrating or validating the measurement is not always part of the standard, which could lead to results that differ from one laboratory to another. A proposed user viscosity…, ASTM Committee E37 Next Meeting:, March 14, 2014, ASTM International Headquarters, West Conshohocken, Pa., Technical Contact:, Roger Blaine, Corvallis, Ore., Phone: 302-559-6827; roger.l.blaine@gmail.com, ASTM Staff Contact:, Tom O'Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9493
-
Methods of examining large girth gear teeth to detect surface breaking flaws have often been time-consuming and limited in terms of data collected. However, a new ASTM International standard provides a more effective method for gear examination using eddy current array, a technology that has been widely used but, until now, not standardized. ASTM E2905/E2905M , Practice for Examination of Mill…, ASTM Committee E07 Next Meeting:, June 2-6, 2013, ASTM International Headquarters, West Conshohocken, Pa., Technical Contact:, Tom Shumka, Global Inspections-NDT, Inc., Kelowna, British Columbia, Canada, Phone: 250-762-5525; tom@global-ndt.ca, ASTM Staff Contact:, Kathleen McClung, Phone: 610-832-9717; kmcclung@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9374
-
ASTM International Committee F11 on Vacuum Cleaners has formed a new task group to develop proposed standards for high efficiency particulate air filtration, typically known as HEPA. The task group, part of Subcommittee F11.23 on Filtration, will develop standards to clarify methodology and criteria used to define HEPA filtration for sealed vacuum cleaner systems and filter components used in…, ASTM Committee F11 Next Meeting:, May 20-22, 2013, May Committee Week, Indianapolis, Ind., Technical Contact:, Zoe Wilson, Bissell Homecare Inc., Grand Rapids, Mich., Phone: 616-735-5142; zoe.wilson@bissell.com , ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9338
-
Phased array probes are a recently developed technology that offers significant advantages in the detection, sizing and imaging of defects that can affect the structural components of airplanes, bridges, power plants and other critical areas. A new ASTM International standard describes testing that can be done on various arrays to ensure that all inspectors are using similar testing equipment.…, ASTM Committee E07 Next Meeting:, June 2-6, 2013, ASTM International Headquarters, West Conshohocken, Pa., Technical Contact:, Michael Moles, Olympus NDT, Waltham, Mass., Phone: 416-831-4428; michael.moles@olympusndt, ASTM Staff Contact:, Kathleen McClung, Phone: 610-832-9717; kmcclung@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9299
-
The increase in the number of floor care products in the marketplace that employ wet extraction cleaning systems is the leading factor in the development of a standard that describes a laboratory test for the cleaning effectiveness of such systems. ASTM F2828 , Test Method for Assessing Carpet Cleaning Effectiveness in Terms of Visual Appearance Change When Cleaned with a Wet Extraction Cleaning…, ASTM Committee F11 Next Meeting:, Nov. 12-14, November Committee Week, Atlanta, Ga., Technical Contact:, Kenneth M. Lee, Bissell Homecare Inc., Grand Rapids, Mich., Phone: 616-791-0608; ken.lee@bissell.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9290
-
A new ASTM International standard provides the necessary background and describes the step-by-step process for analyzing nondestructive testing hit/miss data resulting from a probability of detection (POD) examination, including minimum requirements for validating the resulting POD curve. The new standard, ASTM E2862 , Practice for Probability of Detection Analysis for Hit/Miss Data, has been…
-
A recently approved ASTM International standard will be used by neutron imaging facilities, particularly those that are setting up neutron tomography imaging systems. The new standard, ASTM E2861 , Test Method for Measurement of Beam Divergence and Alignment in Neutron Radiologic Beams, was developed by Subcommittee E07.05 on Radiology (Neutron) Method , part of ASTM International Committee E07…