A proposed new ASTM International standard is being developed for mounting plastic pipe and tube in the Steiner tunnel furnace. The draft procedure will help determine the fire-related properties of the pipe and tube in accordance with ASTM E84, Test Method for Surface Burning Characteristics of Building Materials. ASTM WK44535 , Practice for Mounting of Plastic Pipe, Plastic Tubing, Plastic Pipe…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee, Toronto, Ontario, Canada, Technical Contact:, Joe Zicherman, Fire Cause Analysis, Berkeley, Calif., Phone: 510-649-1300; zicherman46@gmail.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9635
-
A wildland-urban interface is a transitional zone between unoccupied land and human development. There are currently more than 40 million homes located within WUI areas throughout the United States. A proposed new ASTM standard will be used to alleviate the issue of fire conditions that exist due to eaves and other projections in structures that exist in WUI areas. ASTM WK37414, Test Method for…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee Week, Toronto, Ontario, Canada, Technical Contact:, John Simontacchi, Firefree Coatings Inc., San Rafael, Calif., Phone: 415-459-6488; jsimontacchi@firefree.com , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9529
-
A proposed new ASTM International standard will be helpful in selecting glass or glazing that has a proper communication transmittance rate for the location in which it is being used. ASTM WK41897 , Test Method for EMI Transmittance and Shielding Rating for Glazing Infill, is being developed by Subcommittee F12.10 on Systems Products and Services , part of ASTM International Committee F12 on…, ASTM Committee F12 Next Meeting:, Oct. 21-21, 2013, October Committee Week, Jacksonville, Fla., Technical Contact:, Julia Schimmelpenningh, Eastman Chemical Co., Springfield, Mass., Phone: 413-730-3413; jcschi@eastman.com , ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9421
-
It happens all too often: a driver suddenly loses control of a car, sending it into a storefront or other pedestrian area. Property damage and serious injuries, sometimes fatal, can result from these accidents. In an effort to minimize the damage caused by such crashes, ASTM International Committee F12 on Security Systems and Equipment is developing a proposed new standard, ASTM WK13074 , Test…, ASTM Committee F12 Next Meeting:, Oct. 22-24, 2012, October Committee Week, Atlanta, Ga., Technical Contacts:, Rob Reiter, Storefront Safety Consultant, Phone: 909-964-2906; r ob.reiter.pp@gmail.com ; Dean Alberson, Texas Transportation Institute, Texas A&M University, Phone: 979-458-3874; d-alberson@tamu.edu, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindler@astm.org R elease #9263
-
A new test method is the latest in a series of ASTM International standards being developed to address the protection of exterior portions of structures during fires. The new standard, ASTM E2726/E2726M , Test Method for Evaluating the Fire-Test-Response of Deck Structures to Burning Brands, is being developed by Subcommittee E05.14 on External Fire Exposures , part of ASTM International…
-
ASTM International Committee E21 on Space Simulation and Applications of Space Technology is requesting input on upcoming revisions for two standards under the jurisdiction of Subcommittee E21.05 on Contamination . The two standards to be revised are ASTM F21 , Test Method for Hydrophobic Surface Films by the Atomizer Test, and ASTM F22 , Test Method for Hydrophobic Surface Films by the Water-…
-
A new ASTM standard will provide the United States building codes with a test method designed to test a heating, ventilation and air conditioning duct system or its materials for fire resistance and other durability requirements. ASTM E2816 , Test Methods for Fire Resistive Metallic HVAC Duct Systems, was developed by Subcommittee E05.11 on Fire Resistance , under the jurisdiction of ASTM…
-
ASTM International Committee F12 on Security Systems and Equipment invites all interested parties to participate in the current revision of ASTM F967 , Practice for Security Engineering Symbols. The standard is under the jurisdiction of Subcommittee F12.10 on Systems, Products and Services. According to Ed Conrath, senior principal, Protection Engineering Consultants, and F12 committee chairman,…
-
Fire test laboratories, caulk and sealant manufacturers, and code officials will be the primary users of a new ASTM International standard, ASTM E2690 , Practice for Specimen Preparation and Mounting of Caulks and Sealants to Assess Surface Burning Characteristics. The standard was developed by Subcommittee E05.22 on Surface Burning, which is part of ASTM International Committee E05 on Fire…, ASTM Committee E05 Next Meeting:, June 12-15, 2011, June Committee Week, Anaheim, Calif., Technical Contact:, Paul Hough, Armstrong World Industries, Lancaster, Pa., Phone: 717-396-4195; pahough@armstrong.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8723
-
Subcommittee E05.11 on Fire Resistance is responsible for two new standards recently approved by ASTM International Committee E05 on Fire Standards. FIRE-RESISTANCE EXPERIMENTS It is a common practice to modify the tests contained in ASTM E119 , Test Methods for Fire Tests of Building Construction and Materials, in order to gather information on the effect of altering specific variables. However…