Search
Advanced search
Filter by category
Filter by committee
Search results
-
Abstracts are being solicited for a conference on Detection Limits sponsored by ASTM International Committee D22 on Air Quality . The conference will be held on August 29-31, 2016, at the DoubleTree Raleigh – Brownstone – University, Raleigh, N.C. The goal of the conference is to provide a forum to educate, discuss, and debate the various aspects of detection limits as applied to the various…, ASTM Staff Contact:, Hannah Sparks, tel +1.610.832.9677; hsparks@astm.org Release #10082
-
A proposed ASTM standard will meet the need for a method that labs can follow when testing samples for mold. The proposed standard (WK17177, Test Method for Examination of Fungal Structures on Tape Lift Samples by Optical Microscopy) will provide labs with an approach based on quality and science. The primary users of the standard will be labs that provide services in the fields of occupational…, Committee D22 on Air Quality Next Meeting:, April 26-May 1, 2015, April committee week, Anaheim, Calif., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Terri L. Williams, Wisconsin Occupational Health Laboratory, University of Wisconsin, Madison, Wis., tel +1.608.224.6261; terri.williams@slh.wisc.edu, ASTM Staff Contact:, Jeffrey Adkins, tel +1.610.832.9738; jadkins@astm.org Release # 9797 March 17, 2015 ###
-
Taking a tape-lift sample is one of the main practices used by indoor environmental quality investigators for detecting whether mold structures (for example, spores and hyphae) have either settled onto or colonized the surface. Despite the popularity of the method, there can be significant inconsistency in how tape lifts are collected. A new ASTM standard, ASTM D7910 , Practice for the Collection…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, John M. Neville, Ph.D., Bureau Veritas North America Inc., Novi, Mich., Phone: 248-344-3042; john.neville@us.bureauveritas.com, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9655
-
A new standard, ASTM D7886 , Practice for Asbestos Exposure Assessments for Repetitive Maintenance and Installation Tasks, will aid those testing asbestos exposures by quantifying such exposure levels. Regulations set forth by the U.S. Occupational Safety and Health Administration require that worker exposure to asbestos be determined with a “high level of certainty.” “ASTM D7886 overcomes the…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, Andrew F. Oberta, MPS, CIH, The Environmental Consultancy, Austin, Texas, Phone: 512-266-1368; andyobe@aol.com , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9639
-
Solid, round, fine wire is often used by the medical industry in devices such as catheter guide wires, stents for the repair of arteries and containment vessels such as vena cava filters. A new ASTM International standard, ASTM E2948 , Test Method for Conducting Rotating Bending Fatigue Tests of Solid Round Fine Wire, will be used to determine the fatigue life characteristics of such wire in…, ASTM Committee E08 Next Meeting:, Nov. 10-13, 2014, November Committee Week, New Orleans, La., Technical Contact:, K.L. Jerina, Washington University, St. Louis, Mo., Phone: 314-935-4960; jerinak@seas.wustl.edu ; and M.R. Mitchell, Mechanics and Materials Consulting LLC, Flagstaff, Ariz., mrmitchell@illinoisalumni.org , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9613
-
Gaseous hydrogen fluoride is a harsh respiratory irritant; the inhalation of hydrofluoric acid mists causes severe lung damage in exposed workers. A proposed new ASTM standard, WK38734 , Test Method for the Determination of Particulate Fluorides and Hydrofluoric Acid Using Filter Sampling and Suppressed Ion Chromatography, will be used to prevent overexposure of hydrofluoric acid/hydrogen…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, Dietmar Breuer, IFA, Sankt Augustin, Germany, Phone: +49 (0) 2241 231-2533; dietmar.breuer@dguv.de , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9585
-
While monitoring air quality is important in many situations, a variety of different quantitative passive samplers are available for such work. A proposed new ASTM standard, ASTM WK45755 , Guide for Selection of Quantitative Passive Samplers for Volatile Organic Compounds in Air, will help users decide which air sampler type will best suit their needs. ASTM WK45755 will cover issues such as the…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, Nicola Watson, Markes International, Loveland, Ohio, Phone: 513-488-6161; nwatson@markes.com , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9578
-
A new ASTM International standard will enable fracture toughness testing on defects that are directly analogous to those commonly found in structural applications. ASTM E2899 , Test Method for Measurement of Initiation Toughness in Surface Cracks under Tension and Bending, was developed by Subcommittee E08.07 on Fracture Mechanics , part of ASTM International Committee E08 on Fatigue and Fracture…, ASTM Committee E08 Next Meeting:, Nov. 11-14, 2013, November Committee Week, Jacksonville, Fla., Technical Contact:, Douglas N. Wells, NASA-MSFC, Huntsville, Ala., Phone: 256-544-3300; douglas.n.wells@nasa.gov, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9507
-
A new ASTM International standard is focused exclusively on testing soil for asbestos. ASTM D7521 , Test Method for Determination of Asbestos in Soil, was developed by Subcommittee D22.07 on Sampling and Analysis of Asbestos , part of ASTM International Committee D22 on Air Quality . According to Alan Segrave, division manager, laboratory services, Bureau Veritas, and an ASTM D22 member, many…, ASTM Committee D22 Next Meeting:, April 14-17, April Committee Week, Indianapolis, Ind., Technical Contact:, Alan M. Segrave, Bureau Veritas North America Inc., Kennesaw, Ga., Phone: 770-590-6706; alan.segrave@us.bureauveritas.com, ASTM Staff Contact:, David Bradley, Phone: 610-832-9681; dbradley@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9295
-
Richard W. Neu, Ph.D., a professor in the Wodruff School of Mechanical Engineering at the Georgia Institute of Technology in Atlanta, Ga., has received the ASTM International Award of Merit from Committee E08 on Fatigue and Fracture . The Award of Merit and its accompanying title of fellow is ASTM’s highest organizational recognition for individual contributions to standards activities. Neu, who…