Rheologists are encouraged to join in the development of a proposed new practice that will help standardize calibration of rotational rheometers to obtain accurate normal force measurements. ASTM WK33687 , Practice for Normal Force Calibration for Rotational Rheometers, is being developed by Subcommittee E37.08 on Rheology , part of ASTM International Committee E37 on Thermal Measurements . The…, ASTM Committee E37 Next Meeting:, Aug. 10-11, in conjunction with the North American Thermal Analysis Society Annual Conference, Des Moines, Iowa, Technical Contact:, Kenneth Aniunioh, Shimadzu Scientific Instruments, Laurel, Md., Phone: 864-633-7690; kenebaano@yahoo.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8923
-
A newly approved standard, ASTM D7338 , Guide for the Assessment of Fungal Growth in Buildings, has been developed to provide a go-to reference for anyone testing for mold in buildings. The new standard was developed by Subcommittee D22.08 on Sampling and Analysis of Mold, part of ASTM International Committee D22 on Air Quality. “The lack of consensus standards in the fungal sampling and analysis…, ASTM Committee D22 Next Meeting:, April 10-13, April Committee Week, Anaheim, Calif., Technical Contact:, Lisa Rogers, Mycometer, Inc., Tampa, Fla., Phone: 813-831-6511; lrogers@mycometer.com, ASTM Staff Contact:, David Bradley, Phone: 610-832-9681; dbradley@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8788
-
A new ASTM International standard will provide gasket manufacturers a test for measuring creep and compression that can be used for R&D and material comparisons, and as a quality assurance tool. ASTM F2837 , Test Method for Hot Compression Properties of Gasket Materials, was developed by Subcommittee F03.40 on Chemical Test Methods, under the jurisdiction of ASTM International Committee F03…, ASTM Committee F03 Next Meeting:, Oct 12-13, October Committee Week, San Antonio, Texas, Technical Contact:, James Lingenfelder, Gasket Resources Inc., Houston, Texas, Phone: 713-856-9445; jtling@durlon.com, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8695/Sept2010
-
Air permits from regulatory agencies, such as the U.S. Environmental Protection Agency (USEPA), often require the measurement of a plume's opacity as the plume is emitted from a stationary point source (for example, smokestacks) in the outdoor ambient environment. While such opacity is often visually measured by human observers as “certified smoke readers,” an opacity measurement method using…
-
The ASTM International Proficiency Testing Center is pleased to offer a 2010 Proficiency Testing Program on Thermal Analyses of Plastics (TAP) to laboratories who need a statistical quality assurance tool that will enable them to improve and maintain a high level of performance in conducting ASTM Differential Scanning Calorimetry (DSC), Oxidative-Induction Time (OIT) by Differential Scanning…, ASTM D3418, , Standard Test Method for Transition Temperatures and Enthalpies of Fusion and Crystallization of Polymers by Differential Scanning Calorimetry (DSC);, ASTM D3850, , Standard Test Method for Rapid Thermal Degradation of Solid Electrical Insulating Materials By Thermogravimetric Method (TGA); and, ASTM D3895, , Standard Test Method for Oxidative-Induction Time of Polyolefins by Differential Scanning Calorimetry. For each test trial, laboratory participants receive two sample materials along with interactive electronic data report forms and test instructions. Using the specified ASTM program tests, participating laboratories conduct the tests of their choice that they routinely run. Upon completion of…
-
The measurement of acid mist is becoming increasingly important due to recent actions taken by the U.S. Environmental Protection Agency on fine particles (2.5 micrometers in diameter and smaller) that are unhealthy to breathe. ASTM International Committee D22 on Air Quality is currently working on a proposed standard for measuring acid mists that come from combustion sources, WK22846 , Test…
-
ASTM International Committee F03 on Gaskets has developed and approved a new standard that can be used to evaluate gasket materials covered by ASTM F104 , Classification System for Nonmetallic Gasket Materials. The new standard, F2716 , Practice for Comparison of Nonmetallic Flat Gaskets in High Pressure Saturated Steam, is under the jurisdiction of Subcommittee F03.10 on Composite Gaskets. ASTM…
-
A new ASTM International standard responds to a recent emphasis by regulatory agencies that firms manufacturing drug products demonstrate the efficacy of disinfectants used in controlled environments. The standard, ASTM E2614 , Guide for Evaluation of Cleanroom Disinfectants, was developed by Subcommittee E35.15 on Antimicrobial Agents, part of ASTM International Committee E35 on Pesticides and…
-
A new ASTM International standard provides guidance for using data generated by ASTM standards in testing for asbestos in surface dust. ASTM D 7390 , Guide for Evaluating Asbestos in Dust on Surfaces by Comparison Between Two Environments, was approved by ASTM International Committee D22 on Air Quality, part of Subcommittee D22.07 on Sampling and Analysis of Asbestos. According to James Millette…
-
A new ASTM International standard will provide a method to consistently address indoor air quality complaints in residential buildings and to guide IAQ investigations in an efficient manner. The standard, D 7297 , Practice for Evaluating Residential Indoor Air Quality Concerns, is under the jurisdiction of Subcommittee D22.05 on Indoor Air, part of ASTM International Committee D22 on Air Quality…