Search
Advanced search
Filter by category
Filter by committee
Search results
-
A new ASTM International test method will help determine the hydraulic capacity of treatment devices that filter stormwater runoff before it reaches bodies of water. “This standard will help engineers create ensure that treatment devices that are the right sizehave adequate capacity to treat flows of expected stormwater runoff flow rates,” says ASTM member Dr. Peter Weiss, a professor in the…, Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org, Technical Contact:, Peter Weiss, tel +1.219.464.5220; peter.weiss@valpo.edu, ASTM Staff Contact:, Joseph Hugo, tel +1.610.832.9740; jhugo@astm.org Release #10062
-
ASTM International’s Fire Committee ( E05 ) is developing a standard that will test fire resistance of wooden utility poles. Utility companies and coating and treatment manufacturers will use the standard to test new products that could protect the poles. “Utility poles are frequently exposed to high intensity wildfires throughout the world,” says ASTM member Brent M. Pickett, Ph.D. “If these…, ASTM Committee E05 on Fire Next Meeting:, June 27-30, 2016, June Committee Week, Chicago, Ill., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Brent M. Pickett, Ph.D., Western Fire Center Inc., Kelso, Wash., tel +1.360.423.1400; brent@westernfire.com , ASTM Staff Contact:, Thomas O’Toole, tel +1.610.832.9739; totoole@astm.org Release #9989
-
A new ASTM standard provides a quick and easy way to estimate the average size of powder particles used in a wide variety of industrial applications. The new standard ( E2980 , Test Methods for Estimating Average Particle Size of Powders Using Air Permeability) reflects advances in measurement technology that lead to better precision. According to ASTM member Frank J. Venskytis, an independent…, ASTM Committee E29 on Particle and Spray Characterization Next Meeting:, April 27-28, 2016 Hollywood, Fla., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Frank J. Venskytis, Clayton, N.C., tel +1.919.553.8050; frankvenskytis@gmail.com, ASTM Staff Contact:, Katerina Koperna, tel +1.610.832.9728; kkoperna@astm.org Release #9965
-
Adopted in 2005, Chapter 7A of the California Building Code describes provisions for attic vents for new construction in wildfire-prone areas. While the California code notes that attic vents should resist the intrusion of embers and flames, there had not been a standard to evaluate such intrusion. A new standard, ASTM E2886/E2886M , Test Method for Evaluating the Ability of Exterior Vents to…, ASTM Committee E05 Next Meeting:, Dec. 8-11, 2014, December Committee, New Orleans, La., Technical Contact:, Stephen Quarles, Insurance Institute for Business and Home Safety, Richburg, S.C., Phone: 803-789-4209; squarles@ibhs.org , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9617
-
A new ASTM International standard, ASTM E2872 , Guide for Determining Cross-Section Averaged Characteristics of a Spray Using Laser-Diffraction Instruments in a Wind Tunnel Apparatus, will be used to guide the characterization of nozzles and atomizers using laser diffraction instruments. ASTM E2872 is primarily applicable to aerial agricultural spraying, aerial forest sprays and air-blast…, ASTM Committee E29 Next Meeting:, Oct. 6-7, 2014, October Committee Week, New Orleans, La., Technical Contact:, Gordon Holloway Ph.D., University of New Brunswick, Fredericton, New Brunswick, Canada; Phone: 506-447-3108; holloway@unb.ca, ASTM Staff Contact:, Katerina Koperna, Phone: 610-832-9728; kkoperna@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9592
-
A large and diverse set of manufactured materials are in powdered form at one stage or another. No matter what the material is, from cement to metered dose inhaler ingredients, product performance is related to particle size distribution. “The strength of concrete is related to the fineness of the cement powder used, but the danger with very fine grades is excessive heating on setting,” says…, ASTM Committee E29 Next Meeting:, Oct. 6-7, 2014, October Committee Week, New Orleans, La., Technical Contact:, Alan F. Rawle, Ph.D., Malvern Instruments, Westborough, Mass., Phone: 508-768-6434; alan.rawle@malvern.com , ASTM Staff Contact:, Katerina Koperna, Phone: 610-832-9728; kkoperna@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9576
-
A proposed new ASTM International standard is being developed for mounting plastic pipe and tube in the Steiner tunnel furnace. The draft procedure will help determine the fire-related properties of the pipe and tube in accordance with ASTM E84, Test Method for Surface Burning Characteristics of Building Materials. ASTM WK44535 , Practice for Mounting of Plastic Pipe, Plastic Tubing, Plastic Pipe…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee, Toronto, Ontario, Canada, Technical Contact:, Joe Zicherman, Fire Cause Analysis, Berkeley, Calif., Phone: 510-649-1300; zicherman46@gmail.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9635
-
A wildland-urban interface is a transitional zone between unoccupied land and human development. There are currently more than 40 million homes located within WUI areas throughout the United States. A proposed new ASTM standard will be used to alleviate the issue of fire conditions that exist due to eaves and other projections in structures that exist in WUI areas. ASTM WK37414, Test Method for…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee Week, Toronto, Ontario, Canada, Technical Contact:, John Simontacchi, Firefree Coatings Inc., San Rafael, Calif., Phone: 415-459-6488; jsimontacchi@firefree.com , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9529
-
Standards development work for stormwater management and other related products will highlight the Dec. 10 meetings of ASTM International Committee C27 on Precast Concrete Products in Jacksonville, Fla., during the December 2013 ASTM Committee Week. Five proposed ASTM standards are under way for precast concrete stormwater management products: • WK26951, Practice for Field Measurement of…, ASTM Committee C27 Next Meeting:, Dec.10-11, 2013, December committee week, Jacksonville, Fla. ASTM Staff Contact: Joe Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9502
-
While machine-placed wet-cast precast concrete retaining wall units have been commercially available since the late 1990s, there has not been an ASTM standard available to cover these products. Now, ASTM International Committee C27 on Precast Concrete Products is working on such a standard. ASTM WK38192 , Specification for Wet-Cast Precast Modular Block Retaining Wall Units, is being developed by…, ASTM Committee C27 Next Meeting:, Dec. 10, 2013, December Committee Week, Jacksonville, Fla., Technical Contact:, Clint Hines, JC Hines and Associates LLC, Anderson, Ohio, Phone: 513-843-6570; clint@jchines.com, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9441