Search
Advanced search
Filter by category
Filter by committee
Search results
-
A watertight septic system ensures its integrity, and demonstrating that integrity is important because such systems have over time become more complex, expensive and critical to both system owners and to the environment. A new ASTM International standard fills a need for an in-field installation test for septic systems. The new standard, ASTM C1719 , Test Method for Installed Precast Concrete…, ASTM Committee C27 Next Meeting:, Dec. 6-7, 2011, December Committee Week, Tampa, Fla., Technical Contact:, Michael R. Miller, Press-Seal Gasket Corp., Fort Wayne, Ind., Phone: 260-918-1626; mmiler@press-seal.com, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9008
-
A new ASTM International standard will be referenced by the International Cyanide Management Code as a guide to ASTM standards related to cyanide management. ASTM D7728 , Guide for Selection of ASTM Analytical Methods for Implementation of International Cyanide Management Code Guidance, was developed by Subcommittee D19.06 on Methods for Analysis for Organic Substances in Water , part of ASTM…
-
A new ASTM International standard covers a special grade of industrial woven wire cloth called filter cloth for general filtration, including the separation of solids from fluids. ASTM E2814 , Guide for Industrial Woven Wire Filter Cloth, was developed by Subcommittee E29.01 on Sieves, Sieving Methods and Screening Media , part of ASTM International Committee E29 on Particle and Spray…, ASTM Committee E29 Next Meeting:, Oct. 31-Nov. 1, 2011, October Committee Week, Tampa, Fla., Technical Contact:, Ken Beyer, Unique Wire Weaving Co., Hillside, N.J., Phone: 908-688-4600; ken@uniquewire.com, ASTM Staff Contact:, Christine Sierk, Phone: 610-832-9728; csierk@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8934
-
A proposed new ASTM International standard will assist users of cyanide analysis methods who want to work in compliance with the International Cyanide Management Code. The Code covers the proper handling of cyanide from production, transportation to processing sites and design of cyanide facilities, including detoxification, storage and release of excess cyanide processing waters. ASTM WK27288 ,…
-
In an action effective on Nov. 10, 2009, 15 methods contained in 10 ASTM standards are among 25 analytical methods that the U.S. Environmental Protection Agency has approved for determining contaminant concentrations in samples collected under the Safe Drinking Water Act. The methods are under the jurisdiction of Subcommittee D19.05 on Inorganic Constituents in Water, part of ASTM Committee D19…, ASTM Committee D19 Next Meeting:, Jan. 17-21, Cocoa Beach, Fla., ASTM Staff Contact:, Brynn Murphy , Phone: 610-832-9640; bmurphy@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #84 52/Jan2010
-
ASTM International Committee E29 on Particle and Spray Characterization has recently approved an extensive revision of ASTM standard E11 , Specification for Wire Cloth and Sieves for Testing Purposes. The revision will lead to better control of the quality of sieve cloths and test sieves. ASTM E11 is under the jurisdiction of Subcommittee E29.01 on Sieves, Sieving Methods and Screening Media.…
-
Analysts in laboratories that use regression-based methods to determine uncertainty in data and customers that request such measurements will be the primary users of a new standard recently approved by ASTM International Committee D19 on Water. ASTM D7366 , Practice for Estimation of Measurement Uncertainty for Data from Regression-Based Methods was developed by Subcommittee D19.02 on Quality…
-
Responding to an increasing level of interest from engineers, regulators and communities, ASTM International Committee C27 on Precast Concrete Products has formed new Subcommittee C27.70 on Precast Concrete Products for Stormwater Management. “New environmental regulations, as well as vastly improved methods of meeting these, have created many new products and practices for stormwater management…
-
Cyanide is routinely analyzed in water samples, often to demonstrate regulatory compliance; however, improper sample collection or pretreatment can result in significant positive or negative bias potentially resulting in unnecessary permit violations or undetected cyanide releases into the environment. Because of the importance and timeliness of these issues, ASTM Subcommittee D19.06 on Methods…
-
Although alkali resistant glass fibers have been commercially available for more than 30 years, there has not been an official standard that clearly defines what is required to make glass fibers resistant to alkali attack without the need for protective coatings. ASTM International Committee C27 on Precast Concrete Products has recently developed such a standard, C 1666/C 1666M , Specification…