Search
Advanced search
Filter by category
Filter by committee
Search results
-
While machine-placed wet-cast precast concrete retaining wall units have been commercially available since the late 1990s, there has not been an ASTM standard available to cover these products. Now, ASTM International Committee C27 on Precast Concrete Products is working on such a standard. ASTM WK38192 , Specification for Wet-Cast Precast Modular Block Retaining Wall Units, is being developed by…, ASTM Committee C27 Next Meeting:, Dec. 10, 2013, December Committee Week, Jacksonville, Fla., Technical Contact:, Clint Hines, JC Hines and Associates LLC, Anderson, Ohio, Phone: 513-843-6570; clint@jchines.com, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9441
-
Stormwater hydrodynamic systems are used to remove settable solids that could cause contamination from stormwater runoff. A proposed new ASTM International standard will be used to specify test material with a common target particle size distribution for use in testing HDS systems. The proposed new standard, ASTM WK39909 , Specification for Surrogate Test Solids for Measuring Performance of…, ASTM Committee C27 Next Meeting:, Dec. 10-11, 2013, December Committee Week, Jacksonville, Fla., Technical Contact:, Adam A. Stevens, CONTECH Engineered Solutions, Scarborough, Maine, Phone: 207-885-9740; stevensa@contech-cpi.com, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9323
-
Coated fabric products used for oil spill response procedures can deteriorate when stored for long periods of time. A proposed new ASTM standard will provide a nondestructive test for stored equipment to be evaluated for continued suitability over time. ASTM WK37298 , Test Method for Determining Storage Life of Coated Fabric Products, is being developed by Subcommittee F20.11 on Control , part of…, ASTM Committee F20 Next Meeting:, Oct. 23-24, 2012, October Committee Week, Atlanta, Ga., Technical Contact:, Peter Lane, Applied Fabric Technologies Inc., Applied Fabric Technologies Inc., Morris Skimmers International LLC, Orchard Park, N.Y., Phone: 716-662-0632; lane@afti.com, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9310
-
ASTM International Committee F20 on Hazardous Substances and Oil Spill Response has approved several standards for in-situ burning. The latest proposed standard on this subject, ASTM WK37324 , Guide for Evaluation of In-Situ Burning Effectiveness, is currently being developed by Subcommittee F20.15 on In-Situ Burning . In-situ burning is a controlled burning, at the spill location, of oil that…, ASTM Committee F20 Next Meeting:, Oct. 23-24, 2012, October Committee Week, Atlanta, Ga., Technical Contact:, Steve Potter, SL Ross Environmental Research Ltd., Ottawa, Ontario, Canada, Phone: 613-232-1564; steve@slross.com, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-932-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9294
-
Many manufacturers have their own methods for testing adhesives for carpet or resilient or wood floor coverings. A new ASTM standard addresses this inconsistency by presenting a set of adhesive requirements that can be used throughout the floor covering industry. The new standard, ASTM D7799 , Specification for Tufted and Woven Broadloom Carpet Adhesives Without Homogenous PVC or Non-PVC Backings…
-
While there are many commercially available stormwater treatment products currently on the market, there is no universal testing standard that would allow the performance of these products to be accurately compared. A proposed new ASTM International standard will fill this need, providing a testing method for stormwater treatment products that use filtration as a primary treatment process. ASTM…
-
A watertight septic system ensures its integrity, and demonstrating that integrity is important because such systems have over time become more complex, expensive and critical to both system owners and to the environment. A new ASTM International standard fills a need for an in-field installation test for septic systems. The new standard, ASTM C1719 , Test Method for Installed Precast Concrete…, ASTM Committee C27 Next Meeting:, Dec. 6-7, 2011, December Committee Week, Tampa, Fla., Technical Contact:, Michael R. Miller, Press-Seal Gasket Corp., Fort Wayne, Ind., Phone: 260-918-1626; mmiler@press-seal.com, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9008
-
A new ASTM International standard will be a useful document for vendors, buyers and regulators in determining the applicability of different types of booms to be used for oil spill response. ASTM F2683 , Guide for Selection of Booms for Oil Spill Response, was developed by Subcommittee F20.11 on Control , part of ASTM International Committee F20 on Hazardous Substances and Oil Spill Response .…
-
The Adhesive and Sealant Council (ASC) is partnering with ASTM International (ASTM) to produce the inaugural “Adhesives and Sealants Sustainability Summit” July 26-27 at the Hyatt O’Hare in Rosemont, Ill. The Sustainability Summit will provide an opportunity for the adhesive and sealant supply chain to discuss all aspects of sustainability as it relates to the sector. “The trend of…, ASC Media Contact:, Matt Croson , ASC President (phone: 301-986-9700, ext. 111 ; matt.croson@ascouncil.org, ASTM Media Contact:, Pat Picariello, director, Developmental Operations, ASTM International (phone: 610-832-9720; ppicarie@astm.org ) May 27, 2011
-
Standards developed by ASTM International Committees F20 on Hazardous Substances and Oil Spill Response and E47 on Biological Effects and Environmental Fate play a role in both the initial response and follow-up to oil spills. The recent spill in the Gulf of Mexico highlights the importance of standards that cover all aspects of oil spill response and cleanup. F20 on Hazardous Substance and Oil…