Search
Advanced search
Filter by category
Filter by committee
Search results
-
A new ASTM International standard will support the sustainability and resiliency of concrete pipes that are reinforced by synthetic fibers. The new standard (soon to be approved as C1818, Specification for Rigid Synthetic Fiber Reinforced Concrete Culvert, Storm Drain and Sewer Pipe) describes a strong and durable option that can be used for underground piping. Pipes in this new standard are used…, ASTM Committee C13 on Concrete Pipe Next Meeting:, Nov. 15-18, 2015, November Committee Week, Tampa, Fla., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Ali Abolmaali, University of Texas, Arlington, Texas, tel +1.817.272.3877; abolmaail@uta.edu, ASTM Staff Contact:, Diane Lake, tel +1.610.832.9661; dlake@astm.org Release #9940
-
A new ASTM test method will test the strength and durability of wood-to-wood adhesives when put under pressures of weight, temperature and humidity. This “creep resistance” standard will soon be available for purchase as ASTM D7966, Test Method for Resistance to Creep of Adhesives in Static Shear by Compression Loading (Wood-to-Wood). Wood-to-wood adhesives are an increasingly essential part of…, ASTM Committee D14 Next Meeting:, April 26-28, 2015, April Committee Week, Anaheim, Calif., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Mark Clark, Momentive Specialty Chemicals Inc., Springfield, Ore., tel +1.541.741.6674; mark.clark@momentive.com, ASTM Staff Contact:, Joseph Hugo, tel +1.610.832.9740; jhugo@astm.org Release #9799 ###
-
Precast reinforced concrete box sections are proving to be a versatile means for the development of infrastructure. The use of segmental box sections is now covered in an ASTM standard, ASTM C1786 , Specification for Segmental Precast Reinforced Concrete Box Sections for Culverts, Storm Drains and Sewers Designed According to AASHTO LRFD. The American Association of State Highway and…, Technical Contact:, Josiah W. Beakley, American Concrete Pipe Association, Irving, Texas, tel +1.972.894.2906; jbeakley@concrete-pipe.org, ASTM Staff Contact:, Diane Lake, tel +1.610.832.9661; dlake@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9745
-
The laboratory conditions test described in a new ASTM International standard will be used by manufacturers to determine the sustained air performance and exhaust emissions of a central vacuum cleaner. ASTM F2826 , Test Method for Evaluating the Sustained Air Performance and Exhaust Emissions of Central Vacuum Cleaning Units, was developed by Subcommittee F11.22 on Air Performance , part of ASTM…, ASTM Committee F11 Next Meeting:, May 5-7, 2014, May Committee Week, Toronto, Ontario, Canada, Technical Contact:, Darrell Nieschwitz, H-P Products Inc., Louisville, Ohio, Phone: 330-875-5556, ext. 2272; dnieschwitz@h-pproducts.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9584
-
A new ASTM International standard will provide a qualitative means to determine the potential effect of plasticizers contained within polyvinylchloride floor covering materials on a specific adhesive. ASTM D7888 , Practice for Evaluating Adhesive and the Effects of Plasticizer Found Within Polyvinylchloride-Backed Floor Coverings, was developed by Subcommittee D14.10 on Working Properties, part…, ASTM Committee D14 Next Meeting:, April 6-8, 2014, April Committee Week, Toronto, Ontario, Canada, Technical Contact:, Larry Press, Helmitin Adhesives Inc., Jacksonville, Fla., Phone: 904-765-2364; l.press@helmit inadehesives.com , ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9533
-
A proposed new ASTM International standard will provide a laboratory conditions test for determining the sustained air performance and exhaust emissions of central vacuum cleaners. ASTM WK14392 , Test Method for Evaluating the Sustained Air Performance and Exhaust Emissions of Central Vacuum Cleaning Units, is being developed by Subcommittee F11.22 on Air Performance , part of ASTM International…, ASTM Committee F11 Next Meeting:, May 5-7, 2014, May Committee Week, Toronto, Ontario, Canada, Technical Contact, : Darrell Nieschwitz, H-P Products Inc., Louisville, Ohio, Phone: 330-875-5556, ext. 2272; dnieschwitz@h-pproducts.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9532
-
ASTM International Committee F11 on Vacuum Cleaners has formed a new task group to develop proposed standards for high efficiency particulate air filtration, typically known as HEPA. The task group, part of Subcommittee F11.23 on Filtration, will develop standards to clarify methodology and criteria used to define HEPA filtration for sealed vacuum cleaner systems and filter components used in…, ASTM Committee F11 Next Meeting:, May 20-22, 2013, May Committee Week, Indianapolis, Ind., Technical Contact:, Zoe Wilson, Bissell Homecare Inc., Grand Rapids, Mich., Phone: 616-735-5142; zoe.wilson@bissell.com , ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9338
-
Since the late 1970s, precast box sections have become an important component in the construction of culverts, storm drains and sewers, but there has not been a comprehensive standard for the installation of such sections. A new ASTM International standard fills this gap. ASTM C1675, Practice for Installation of Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains and…, Technical Contact:, Roman Selig, Hamilton Kent LLC, Birmingham, Ala., Phone: 205-910-0690; roman.selig@hamiltonkent.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9243
-
Load and resistance factor design methodology developed by the American Association of State Highway and Transportation Officials plays a key role in a proposed ASTM standard on the design of culverts and storm drains. ASTM WK38166 , Specification for Manufacture of Precast Reinforced Concrete Three-Sided Structures for Culverts and Storm Drains Designed According to AASHTO LRFD, is being…, Technical Contact:, Balaram K. Singh, P.E., Michigan Department of Transportation, Lansing, Mich., Phone: 517-335-2174; singhb@michigan.gov, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact, : Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9311
-
The increase in the number of floor care products in the marketplace that employ wet extraction cleaning systems is the leading factor in the development of a standard that describes a laboratory test for the cleaning effectiveness of such systems. ASTM F2828 , Test Method for Assessing Carpet Cleaning Effectiveness in Terms of Visual Appearance Change When Cleaned with a Wet Extraction Cleaning…, ASTM Committee F11 Next Meeting:, Nov. 12-14, November Committee Week, Atlanta, Ga., Technical Contact:, Kenneth M. Lee, Bissell Homecare Inc., Grand Rapids, Mich., Phone: 616-791-0608; ken.lee@bissell.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9290