All interested parties are invited to join in the development of a proposed new ASTM International standard that would be used during the design and installation of suspended gypsum ceiling systems for commercial construction. ASTM WK44242 , Practice for Installation of Metal Suspension Ceiling Systems for Gypsum Board Applications, is being developed by Subcommittee C11.03 on Specifications for…, ASTM Committee C11 Next Meeting:, May 5-8, 2014, May Committee Week, Toronto, Ontario, Canada, Technical Contact:, Joseph J. Kelly, Worthington Armstrong Venture, Malvern, Pa., Phone: 610-722-1218; jjkelly@armstrong.com , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9576
-
A wildland-urban interface is a transitional zone between unoccupied land and human development. There are currently more than 40 million homes located within WUI areas throughout the United States. A proposed new ASTM standard will be used to alleviate the issue of fire conditions that exist due to eaves and other projections in structures that exist in WUI areas. ASTM WK37414, Test Method for…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee Week, Toronto, Ontario, Canada, Technical Contact:, John Simontacchi, Firefree Coatings Inc., San Rafael, Calif., Phone: 415-459-6488; jsimontacchi@firefree.com , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9529
-
ASTM C1264 Addresses Origin and Source Labeling of Drywall and Other Gypsum Products, In response to the importation of contaminated drywall that caused health and safety hazards when used in home construction, the Drywall Safety Act of 2012 (PL 112-266) was signed into law by President Barack Obama on Jan. 14, 2013. The new law cites ASTM International standard C1264-11 , Specification for Sampling, Inspection, Rejection, Certification, Packaging, Marking, Shipping, Handling and…, Labeling, The Drywall Safety Act requires the CPSC to set regulations based on C1264 , which was developed by ASTM Subcommittee C11.01 on Specifications and Test Methods for Gypsum Products , part of ASTM Committee C11 on Gypsum and Related Building Materials and Systems . The standard provides the CPSC, states, suppliers and consumers with an effective tool for supply chain communication by specifying…, Up-to-Date Standards, Under the act’s provisions, ASTM International will notify the CPSC of any updates to the labeling standard within 60 days; the CPSC will then have 90 days to disapprove ASTM’s recommended changes. If the CPSC accepts the most updated version of the ASTM standard, then the new version becomes effective 180 days after ASTM’s initial notification., Sulfur Content, Because sulfur content levels in drywall have been associated with elevated corrosion rates in a home, the act requires that the CPSC issue a regulation that limits the sulfur content for drywall manufactured in the United States or imported from abroad. In lieu of issuing a federal rule, the CPSC may adopt a voluntary consensus standard, developed by C11.01, that addresses the level of sulfur…, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9277
-
Current members of ASTM International Committees C01 on Cement and C09 on Concrete and Concrete Aggregates , and other interested parties, are invited to join a new C01 subcommittee, C01.98 on Sustainability Assessment. The scope of C01.98 is to support the development and maintenance of standards related to methodologies and metrics for assessing sustainability in the manufacture and use of…
-
A new test method is the latest in a series of ASTM International standards being developed to address the protection of exterior portions of structures during fires. The new standard, ASTM E2726/E2726M , Test Method for Evaluating the Fire-Test-Response of Deck Structures to Burning Brands, is being developed by Subcommittee E05.14 on External Fire Exposures , part of ASTM International…
-
A new ASTM International practice provides a standard for preparing a mixture of cement paste that will simulate the shearing experienced by the cement paste in concrete. The new standard, ASTM C1738 , Practice for High-Shear Mixing of Hydraulic Cement Pastes, was developed by Subcommittee C01.22 on Workability , part of ASTM International Committee C01 on Cement . According to Chiara Ferraris,…
-
A new ASTM standard will provide the United States building codes with a test method designed to test a heating, ventilation and air conditioning duct system or its materials for fire resistance and other durability requirements. ASTM E2816 , Test Methods for Fire Resistive Metallic HVAC Duct Systems, was developed by Subcommittee E05.11 on Fire Resistance , under the jurisdiction of ASTM…
-
Fire test laboratories, caulk and sealant manufacturers, and code officials will be the primary users of a new ASTM International standard, ASTM E2690 , Practice for Specimen Preparation and Mounting of Caulks and Sealants to Assess Surface Burning Characteristics. The standard was developed by Subcommittee E05.22 on Surface Burning, which is part of ASTM International Committee E05 on Fire…, ASTM Committee E05 Next Meeting:, June 12-15, 2011, June Committee Week, Anaheim, Calif., Technical Contact:, Paul Hough, Armstrong World Industries, Lancaster, Pa., Phone: 717-396-4195; pahough@armstrong.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8723
-
Subcommittee E05.11 on Fire Resistance is responsible for two new standards recently approved by ASTM International Committee E05 on Fire Standards. FIRE-RESISTANCE EXPERIMENTS It is a common practice to modify the tests contained in ASTM E119 , Test Methods for Fire Tests of Building Construction and Materials, in order to gather information on the effect of altering specific variables. However…
-
Several years ago, a housing boom followed by recovery from damage caused by Hurricane Katrina and other storms created a surge in the use of imported drywall in the United States, particularly in the southeastern area of the country. However, since then, there have been a number of complaints concerning corrosion and odors in homes in which some of this drywall was used. Interim guidance…