Sealant manufacturers will use a new ASTM International standard to evaluate new products and changes to these products due to exposure to weather. The new standard, ASTM C1735 , Test Method for Measuring the Time Dependent Modulus of Sealants Using Stress Relaxation, is under the jurisdiction of Subcommittee C24.20 on General Test Methods , part of ASTM International Committee C24 on Building…, ASTM Committee C24 Next Meeting:, Jan. 8-10, 2012, Ft. Lauderdale, Fla., Technical Contact:, Christopher C. White, Ph.D., National Institute of Standards and Technology, Gaithersburg, Md., Phone: 301-975-6016; christopher.white@nist.gov, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9005
-
Rheologists are encouraged to join in the development of a proposed new practice that will help standardize calibration of rotational rheometers to obtain accurate normal force measurements. ASTM WK33687 , Practice for Normal Force Calibration for Rotational Rheometers, is being developed by Subcommittee E37.08 on Rheology , part of ASTM International Committee E37 on Thermal Measurements . The…, ASTM Committee E37 Next Meeting:, Aug. 10-11, in conjunction with the North American Thermal Analysis Society Annual Conference, Des Moines, Iowa, Technical Contact:, Kenneth Aniunioh, Shimadzu Scientific Instruments, Laurel, Md., Phone: 864-633-7690; kenebaano@yahoo.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8923
-
The ASTM International Proficiency Testing Center is pleased to offer a 2010 Proficiency Testing Program on Thermal Analyses of Plastics (TAP) to laboratories who need a statistical quality assurance tool that will enable them to improve and maintain a high level of performance in conducting ASTM Differential Scanning Calorimetry (DSC), Oxidative-Induction Time (OIT) by Differential Scanning…, ASTM D3418, , Standard Test Method for Transition Temperatures and Enthalpies of Fusion and Crystallization of Polymers by Differential Scanning Calorimetry (DSC);, ASTM D3850, , Standard Test Method for Rapid Thermal Degradation of Solid Electrical Insulating Materials By Thermogravimetric Method (TGA); and, ASTM D3895, , Standard Test Method for Oxidative-Induction Time of Polyolefins by Differential Scanning Calorimetry. For each test trial, laboratory participants receive two sample materials along with interactive electronic data report forms and test instructions. Using the specified ASTM program tests, participating laboratories conduct the tests of their choice that they routinely run. Upon completion of…
-
A new ASTM International standard will have applications in a variety of factories, on artificial turfs and playing surfaces, and even in the classroom. The new standard, G194 , Test Method for Measuring Rolling Friction Characteristics of a Spherical Shape on a Flat Horizontal Surface, was developed by Subcommittee G02.50 on Friction, part of ASTM International Committee G02 on Wear and Erosion…
-
The use of rolling devices can provide a means to evaluate the adhesion of weather seals, for quality control in new installations, general evaluation of existing installations, and the investigation of water and air leakage through building enclosures. In order to better facilitate the use of rolling devices, ASTM International Committee C24 on Building Seals and Sealants is developing a…
-
Testing the oxygen permeation of packaging material is important for the suppliers of various barrier materials, as well as users of these materials in the food, pharmaceutical and consumer product companies, universities, research organizations and other industries. This kind of testing is covered in a new ASTM International standard approved by Committee F02 on Flexible Barrier Packaging, F2622…
-
Sterilized medical devices are indispensable to doctors and surgeons around the world. Peel pouches, otherwise known as preformed sterile barrier systems, are used to keep these devices sterile during all physical handling. These pouches can be made with a wide variety of material and are produced by many different suppliers, but the trait all pouches must share is the ability to protect devices…
-
A need for a new test method to determine the effective thermal conductivity of fire resistive materials at high temperatures has prompted ASTM International Committee E37 on Thermal Measurements to begin work on a proposed new standard, WK12643 , Test Method for Slug Calorimetry. The proposed standard is under the jurisdiction of Subcommittee E37.05 on Thermophysical Properties. According to…
-
ASTM International Committee C24 on Building Seals and Sealants invites interested parties to participate in the development of a proposed new standard that will use photographs to illustrate various types of sealant failures. WK11731 , Guide for Diagnosing Sealant Failure by Comparison to Reference Photographs, is under the jurisdiction of Subcommittee C24.10 on Specifications, Guides and…
-
ASTM International Committee E37 on Thermal Measurements is seeking participation in a new subcommittee, E37.09 on Biological Calorimetry. Since its inception, the focus of Committee E37 has been the creation of methods for the calibration and use of thermal analysis instrumentation. One of the first types of thermal analysis instruments that was developed commercially on a large scale was…