Search
Advanced search
Filter by category
Filter by committee
Search results
-
Stormwater hydrodynamic systems are used to remove settable solids that could cause contamination from stormwater runoff. A proposed new ASTM International standard will be used to specify test material with a common target particle size distribution for use in testing HDS systems. The proposed new standard, ASTM WK39909 , Specification for Surrogate Test Solids for Measuring Performance of…, ASTM Committee C27 Next Meeting:, Dec. 10-11, 2013, December Committee Week, Jacksonville, Fla., Technical Contact:, Adam A. Stevens, CONTECH Engineered Solutions, Scarborough, Maine, Phone: 207-885-9740; stevensa@contech-cpi.com, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9323
-
There has long been a need within the tissue engineering/regenerative medicine sector for three-dimensional reference scaffolds to serve as physical standards for the materials that are used as beds for the growth of cell cultures. The National Institute of Standards and Technology has created such references, which will eventually be accompanied by a proposed ASTM International standard that…, ASTM Committee F04 Next Meeting:, May 21-24, 2013, May Committee Week, Indianapolis, Ind., Technical Contact:, Carl G. Simon Jr., Ph.D., Biosystems and Biomaterials Division, National Institute of Standards and Technology, Gaithersburg, Md., Phone: 301-975-8574; carl.simon@nist.gov, ASTM Staff Contact:, Pat Picariello, Phone: 610-832-9720; ppicariello@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9298
-
Many types of surgical implants and other medical devices are made of polymeric materials. A new ASTM standard covers the raw material properties for a high strength polymer used for surgical implants. ASTM F2820 , Specification for Polyetherketoneketone (PEKK) Polymers for Surgical Implant Applications, has been developed by ASTM International Subcommittee F04.11 on Polymeric Materials , part of…, ASTM Committee F04 Next Meeting:, May 21-24, 2013, May Committee Week, Indianapolis, Ind., Technical Contact:, Jon P. Moseley, Ph.D., Wright Medical Technology Inc., Arlington, Tenn., Phone: 901-867-4414; jon.moseley@wmt.com, ASTM Staff Contact:, Pat Picariello, Phone: 610-832-9720, ppicariello@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9276
-
A new ASTM International standard provides a much-needed methodology for determining the shelf life of various attributes of endovascular devices. The new standard, ASTM F2914 , Guide for Identification of Shelf-Life Test Attributes for Endovascular Devices, was developed by Subcommittee F04.30 on Cardiovascular Standards , part of ASTM International Committee F04 on Medical and Surgical…, ASTM Committee F04 Next Meeting:, Nov. 13-16, 2012, November Committee Week, Atlanta, Ga., Technical Contact:, Benjamin Gundale, Boston Scientific, Maple Grove, Minn., Phone: 763-494-2771; gundaleb@bsci.com, ASTM Staff Contact:, Pat Picariello, Phone: 610-832-9720; ppicarie@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9264
-
While there are many commercially available stormwater treatment products currently on the market, there is no universal testing standard that would allow the performance of these products to be accurately compared. A proposed new ASTM International standard will fill this need, providing a testing method for stormwater treatment products that use filtration as a primary treatment process. ASTM…
-
New functionalities in a particular group of orthopedic spinal devices will be addressed in a proposed new ASTM standard. ASTM WK34549 , Test Methods for Intervertebral Body Fusion Devices with Integrated Fixation Components, is being developed by Subcommittee F04.25 on Spinal Devices , part of ASTM International Committee F04 on Medical and Surgical Materials and Devices . According to Andrew…
-
A watertight septic system ensures its integrity, and demonstrating that integrity is important because such systems have over time become more complex, expensive and critical to both system owners and to the environment. A new ASTM International standard fills a need for an in-field installation test for septic systems. The new standard, ASTM C1719 , Test Method for Installed Precast Concrete…, ASTM Committee C27 Next Meeting:, Dec. 6-7, 2011, December Committee Week, Tampa, Fla., Technical Contact:, Michael R. Miller, Press-Seal Gasket Corp., Fort Wayne, Ind., Phone: 260-918-1626; mmiler@press-seal.com, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9008
-
One of the most important characteristics of a curved surgical needle is how easily it can pass through tissue. This characteristic, known as penetration force, is important for several reasons, which include minimizing scarring and dealing with highly communicable diseases such as hepatitis. ASTM International Committee F04 on Medical and Surgical Materials and Devices is currently developing a…
-
There are currently several uses of alloy UNS R56320 in surgical applications and implants, but the only ASTM surgical standard for the alloys covers tubing [ ASTM F2146 , Specification for Wrought Titanium-3Aluminum-2.5Vanadium Alloy Seamless Tubing for Surgical Implant Applications (UNS R56320)]. A proposed new ASTM standard will reflect the more widespread use of UNS R56320. ASTM WK34079 ,…
-
Epifluorescence microscopes are used to generate fluorescence intensity images in several biology applications. A proposed new ASTM International standard will provide guidance on how to set up an experiment that uses an epifluorescence microscope to ensure that the imaging measurements are quantitative. The proposed standard will also provide guidance on how to use benchmarks to allow…, ASTM Committee F04 Next Meeting:, Nov. 15-18, 2011, November Committee Week, Tampa, Fla., Technical Contact:, John Elliot, National Institute of Standards and Technology, Gaithersburg, Md., Phone: 310-975-8551; jelliott@nist.gov, ASTM Staff Contact:, Pat Picariello, Phone: 610-832-9720; ppicarie@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8945