Search
Advanced search
Filter by category
Filter by committee
Search results
-
There are currently several uses of alloy UNS R56320 in surgical applications and implants, but the only ASTM surgical standard for the alloys covers tubing [ ASTM F2146 , Specification for Wrought Titanium-3Aluminum-2.5Vanadium Alloy Seamless Tubing for Surgical Implant Applications (UNS R56320)]. A proposed new ASTM standard will reflect the more widespread use of UNS R56320. ASTM WK34079 ,…
-
Interested parties are invited to join in the development of a new proposed standard being developed by ASTM International Committee E11 on Quality and Statistics . ASTM WK32565 , Guide for the Use of Non-Parametric Statistical Methods, is under the jurisdiction of Subcommittee E11.10 on Sampling/Statistics . According to Stephen Luko, statistician, Hamilton Sundstrand, Shared Engineering…, ASTM Committee E11 Next Meeting:, Oct. 26-28, 2011, ASTM International Headquarters, West Conshohocken, Pa., Technical Contact:, Stephen N. Luko, Hamilton Sunstrand, Shared Engineering Services, Windsor Locks, Conn., Phone: 860-654-3447; stephen.luko@hs.utc.com, ASTM Staff Contact:, Christine Sierk, Phone: 610-832-9728; csierk@astm.org Release #8978
-
Epifluorescence microscopes are used to generate fluorescence intensity images in several biology applications. A proposed new ASTM International standard will provide guidance on how to set up an experiment that uses an epifluorescence microscope to ensure that the imaging measurements are quantitative. The proposed standard will also provide guidance on how to use benchmarks to allow…, ASTM Committee F04 Next Meeting:, Nov. 15-18, 2011, November Committee Week, Tampa, Fla., Technical Contact:, John Elliot, National Institute of Standards and Technology, Gaithersburg, Md., Phone: 310-975-8551; jelliott@nist.gov, ASTM Staff Contact:, Pat Picariello, Phone: 610-832-9720; ppicarie@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8945
-
A new ASTM International standard will add opportunities for metal injection molded (MIM) medical manufacturers to use materials other than castings and wrought products to develop implants with similar properties at reduced costs. ASTM F2885 , Specification for Metal Injection Molded Titanium-6Aluminum-4Vanadium Components for Surgical Implant Applications, was developed by Subcommittee F04.12…
-
Hydrogels are highly hydrated polymer networks that will play an increasingly important role in the realm of regenerative medicine over the next decade. The reason for the growth of hydrogels is twofold: • Advances in polymer synthesis enable the manufacture of tailored, environmentally sensitive gels; and • A paradigm shift in tissue engineering toward using the body as a bioreactor to repair…, ASTM Committee F04 Next Meeting:, Nov. 15-18, 2011, November Committee Week, Tampa, Fla., Technical Contact:, Melissa Mather, University of Nottingham, Great Britain, Phone: +011-44-5951-5337; melissa.mather@nottingham.ac.uk, ASTM Staff Contact:, Pat Picariello, Phone: 610-832-9720; ppicarie@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8882
-
Measurement systems analysis is an important topic in statistics and quality for engineering, manufacturing, laboratory practice and business process applications. A new ASTM International standard, ASTM E2782 , Guide for Measurement Systems Analysis (MSA), covers many core issues of MSA. ASTM E2782 was developed by Subcommittee E11.20 on Test Method Evaluation and Quality Control, under the…
-
The latest in a series of ASTM International standards developed for the characterization of mobile bearing knees prior to implementation has now been approved by ASTM International Committee F04 on Medical and Surgical Materials and Devices. The new standard, ASTM F2777 , Test Method for Evaluating Knee Bearing (Tibial Insert) Endurance and Deformation Under High Flexion, is under the…
-
Evaluating potential irritant effects to skin is an important part of the overall safety assessment of many consumer products, including feminine hygiene products, fabrics and diapers. The normal use of these products involves contact with the skin, while continuous friction through normal movement can result in mechanical irritation. A new ASTM International standard can now be used to test both…
-
A new ASTM subcommittee seeks to acknowledge the ongoing advances being made in the field of nanostructured inorganic coatings. B08.16 on Nanostructured Coatings, part of ASTM International Committee B08 on Metallic and Inorganic Coatings, is currently developing its first proposed standard, ASTM WK29468 , Specification for Galvanic Protection of Steel Using a Nanostructured Coating of 95 % Zinc…
-
Subcommittee F04.25 on Spinal Devices has been proactive in developing and advancing standards that can be used by the medical community for testing prosthetic devices in their early stages of development. The latest F04.25 standard to provide this opportunity is ASTM F2790 , Practice for Static and Dynamic Characterization of Motion Preserving Lumbar Total Facet Prostheses. Subcommittee F04.25…