Search
Advanced search
Filter by category
Filter by committee
Search results
-
A proposed ASTM International standard will provide best practices for companies that coat pipe with porcelain enamel (glass) lining. Such lining has been used in municipal wastewater, sewage treatment and other water-related industries since the 1960s. Subcommittee B08.12 on Materials for Porcelain Enamel and Ceramic-Metal Systems is developing the standard. Porcelain enamel lining acts as a…, ASTM Committee B08 on Metallic and Inorganic Coatings Next Meeting:, Nov. 18-19, 2015, November Committee Week, Tampa, Fla., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Charles Baldwin, Ferro Corp., tel +1.216.875.6204; charles.baldwin@ferro.com, ASTM Staff Contact:, Diane Lake, tel +1.610.832.9661; dlake@astm.org Release #9827 ###
-
A proposed ASTM standard will meet the need for a method that labs can follow when testing samples for mold. The proposed standard (WK17177, Test Method for Examination of Fungal Structures on Tape Lift Samples by Optical Microscopy) will provide labs with an approach based on quality and science. The primary users of the standard will be labs that provide services in the fields of occupational…, Committee D22 on Air Quality Next Meeting:, April 26-May 1, 2015, April committee week, Anaheim, Calif., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Terri L. Williams, Wisconsin Occupational Health Laboratory, University of Wisconsin, Madison, Wis., tel +1.608.224.6261; terri.williams@slh.wisc.edu, ASTM Staff Contact:, Jeffrey Adkins, tel +1.610.832.9738; jadkins@astm.org Release # 9797 March 17, 2015 ###
-
Temperature can be a key indicator of the integrity of concrete deep foundations. Now, a routinely used temperature assessment method has been developed as a new ASTM standard. According to ASTM member Garland Likins, ASTM D7949 , Test Methods for Thermal Integrity Profiling of Concrete Deep Foundations, was developed to ensure that the correct procedures would be used. “Evaluating the full cross…, ASTM Committee D18 Next Meeting:, June 14-17, 2015, June Committee Week, Anaheim, Calif., Technical Contact:, Garland E. Likins, Pile Dynamics Inc., Kiwanis Lake, Ohio, tel +1.216.831.6131; glikins@pile.com, ASTM Staff Contact:, Robert Morgan, tel +1.610.832.9732; rmorgan@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9754
-
One of the keys to successful remediation of a contaminated property is effective groundwater sampling. A new ASTM standard will aid groundwater samplers by taking a look at three types of passive samplers and their advantages, disadvantages and limitations. The new standard is ASTM D7929 , Guide for Selection of Passive Techniques for Sampling Groundwater Monitoring Wells. The three types of…, ASTM Committee D18 Next Meeting:, Jan. 25-28, 2015, January Committee Week, New Orleans, La., Technical Contact:, Louise Parker, U.S. Army Cold Regions Research, Hanover, N.H., tel +1.603.646.4393; slbparker@comcast.net, ASTM Staff Contact:, Robert Morgan, tel +1.610.832.9732; rmorgan@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9715
-
Vital component of all utility distribution systems, Standards are one solution to ongoing concerns about improperly designed and aging infrastructure. A proposed new ASTM specification will help minimize maintenance expense and improve public safety by providing a definitive standard for one essential infrastructure component, fabricated metal access hatches. The proposed standard is ASTM WK43586 , Specification for the Design, Testing,…, ASTM Committee C27 Next Meeting:, Dec 9-10, December Committee Week, New Orleans, La., Technical Contact:, Tom Elliott, Jensen Precast, Sparks, Nev., tel +1.775.352.6308; telliott@jensenprecast.com, ASTM Staff Contact:, Joseph Hugo, tel +1.610.832.9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9716
-
Taking a tape-lift sample is one of the main practices used by indoor environmental quality investigators for detecting whether mold structures (for example, spores and hyphae) have either settled onto or colonized the surface. Despite the popularity of the method, there can be significant inconsistency in how tape lifts are collected. A new ASTM standard, ASTM D7910 , Practice for the Collection…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, John M. Neville, Ph.D., Bureau Veritas North America Inc., Novi, Mich., Phone: 248-344-3042; john.neville@us.bureauveritas.com, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9655
-
A new standard, ASTM D7886 , Practice for Asbestos Exposure Assessments for Repetitive Maintenance and Installation Tasks, will aid those testing asbestos exposures by quantifying such exposure levels. Regulations set forth by the U.S. Occupational Safety and Health Administration require that worker exposure to asbestos be determined with a “high level of certainty.” “ASTM D7886 overcomes the…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, Andrew F. Oberta, MPS, CIH, The Environmental Consultancy, Austin, Texas, Phone: 512-266-1368; andyobe@aol.com , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9639
-
Gaseous hydrogen fluoride is a harsh respiratory irritant; the inhalation of hydrofluoric acid mists causes severe lung damage in exposed workers. A proposed new ASTM standard, WK38734 , Test Method for the Determination of Particulate Fluorides and Hydrofluoric Acid Using Filter Sampling and Suppressed Ion Chromatography, will be used to prevent overexposure of hydrofluoric acid/hydrogen…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, Dietmar Breuer, IFA, Sankt Augustin, Germany, Phone: +49 (0) 2241 231-2533; dietmar.breuer@dguv.de , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9585
-
While monitoring air quality is important in many situations, a variety of different quantitative passive samplers are available for such work. A proposed new ASTM standard, ASTM WK45755 , Guide for Selection of Quantitative Passive Samplers for Volatile Organic Compounds in Air, will help users decide which air sampler type will best suit their needs. ASTM WK45755 will cover issues such as the…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, Nicola Watson, Markes International, Loveland, Ohio, Phone: 513-488-6161; nwatson@markes.com , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9578
-
Particle size distribution, also known as gradation, refers to the proportions by dry mass of a soil distributed over specified particle-size ranges. Gradation is used to classify soils for engineering and agricultural purposes, since particle size influences how fast or slow water or other fluid moves through a soil. Two proposed new ASTM standards provide test methods for determining particle…, ASTM Committee D18 Next Meeting:, June 22-25, 2014, June Committee Week, Toronto, Ontario, Canada, Technical Contact:, Kendra Adams, Fugro Consultants Inc., Littleton, Colo., Phone: 636-357-4730; ksarocksu@yahoo.com , ASTM Staff Contact:, Robert Morgan, Phone: 610-832-9732; rmorgan@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9575