A new ASTM test method will test the strength and durability of wood-to-wood adhesives when put under pressures of weight, temperature and humidity. This “creep resistance” standard will soon be available for purchase as ASTM D7966, Test Method for Resistance to Creep of Adhesives in Static Shear by Compression Loading (Wood-to-Wood). Wood-to-wood adhesives are an increasingly essential part of…, ASTM Committee D14 Next Meeting:, April 26-28, 2015, April Committee Week, Anaheim, Calif., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Mark Clark, Momentive Specialty Chemicals Inc., Springfield, Ore., tel +1.541.741.6674; mark.clark@momentive.com, ASTM Staff Contact:, Joseph Hugo, tel +1.610.832.9740; jhugo@astm.org Release #9799 ###
-
Adopted in 2005, Chapter 7A of the California Building Code describes provisions for attic vents for new construction in wildfire-prone areas. While the California code notes that attic vents should resist the intrusion of embers and flames, there had not been a standard to evaluate such intrusion. A new standard, ASTM E2886/E2886M , Test Method for Evaluating the Ability of Exterior Vents to…, ASTM Committee E05 Next Meeting:, Dec. 8-11, 2014, December Committee, New Orleans, La., Technical Contact:, Stephen Quarles, Insurance Institute for Business and Home Safety, Richburg, S.C., Phone: 803-789-4209; squarles@ibhs.org , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9617
-
A proposed new ASTM International standard is being developed for mounting plastic pipe and tube in the Steiner tunnel furnace. The draft procedure will help determine the fire-related properties of the pipe and tube in accordance with ASTM E84, Test Method for Surface Burning Characteristics of Building Materials. ASTM WK44535 , Practice for Mounting of Plastic Pipe, Plastic Tubing, Plastic Pipe…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee, Toronto, Ontario, Canada, Technical Contact:, Joe Zicherman, Fire Cause Analysis, Berkeley, Calif., Phone: 510-649-1300; zicherman46@gmail.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9635
-
A new ASTM International standard will provide a qualitative means to determine the potential effect of plasticizers contained within polyvinylchloride floor covering materials on a specific adhesive. ASTM D7888 , Practice for Evaluating Adhesive and the Effects of Plasticizer Found Within Polyvinylchloride-Backed Floor Coverings, was developed by Subcommittee D14.10 on Working Properties, part…, ASTM Committee D14 Next Meeting:, April 6-8, 2014, April Committee Week, Toronto, Ontario, Canada, Technical Contact:, Larry Press, Helmitin Adhesives Inc., Jacksonville, Fla., Phone: 904-765-2364; l.press@helmit inadehesives.com , ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9533
-
A wildland-urban interface is a transitional zone between unoccupied land and human development. There are currently more than 40 million homes located within WUI areas throughout the United States. A proposed new ASTM standard will be used to alleviate the issue of fire conditions that exist due to eaves and other projections in structures that exist in WUI areas. ASTM WK37414, Test Method for…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee Week, Toronto, Ontario, Canada, Technical Contact:, John Simontacchi, Firefree Coatings Inc., San Rafael, Calif., Phone: 415-459-6488; jsimontacchi@firefree.com , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9529
-
The headspace in domestic wastewater collection and treatment systems is a severe environment that can impact even high performance protective coatings. A proposed new ASTM International standard covers an apparatus and set of procedures that are used to create and maintain a simulated sewer headspace environment to be used to test potential coatings. ASTM WK33537 , Practice for Operating the…, ASTM Committee G01 Next Meeting:, Nov. 12-14, 2013, November Committee Week, Jacksonville, Fla., Technical Contact:, Vaughn O’Dea, Tnemec Co. Inc., Kansas City, Mo., Phone: 816-519-2267; odea@tnemec.com , ASTM Staff Contact:, Jennifer Rodgers, Phone: 610-832-9694; jrodgers@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9438
-
ASTM International Committee G01 on Corrosion of Metals has an ongoing commitment to help the oil field industries adopt and use state-of-the-art techniques to control corrosion. As part of this commitment, Subcommittee G01.05 on Laboratory Corrosion Tests has approved ASTM G205 , Guide for Determining Corrosivity of Crude Oils. ASTM G205 is the result of collaboration among members of Task Group…, ASTM Committee G01 Next Meeting:, Nov. 13-15, November Committee Week, Atlanta, Ga., Technical Contact:, Sankara Papavinasam, Ph.D., CanmetMATERIALS, Hamilton, Ontario, Canada, Phone: 613-947-4603; spapavin@nrcan.gc.ca, ASTM Staff Contact:, Jennifer Rodgers, Phone: 610-832-9694; jrodgers@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9297
-
Many manufacturers have their own methods for testing adhesives for carpet or resilient or wood floor coverings. A new ASTM standard addresses this inconsistency by presenting a set of adhesive requirements that can be used throughout the floor covering industry. The new standard, ASTM D7799 , Specification for Tufted and Woven Broadloom Carpet Adhesives Without Homogenous PVC or Non-PVC Backings…
-
A proposed new ASTM International standard will detail a multilevel approach for performing above- and below-ground inspection of transmission poles and lattice towers in the field. ASTM WK35986, Test Method for Field Inspection of Transmission Poles and Lattice Towers, will be used by utilities to provide tools for maintenance departments that inspect and repair transmission structures. ASTM…
-
A new test method is the latest in a series of ASTM International standards being developed to address the protection of exterior portions of structures during fires. The new standard, ASTM E2726/E2726M , Test Method for Evaluating the Fire-Test-Response of Deck Structures to Burning Brands, is being developed by Subcommittee E05.14 on External Fire Exposures , part of ASTM International…