Search
Advanced search
Filter by category
Filter by committee
Search results
-
Three primary factors define the success or failure of any attempt to forcibly penetrate a security fence system: the tools and devices employed, the number of aggressors and their level of sophistication. A newly approved ASTM International standard can be used to measure the resistance of fence systems to such an attempt. ASTM F2781 , Practice for Testing Forced Entry Resistance of Security…, ASTM Committee F14 Next Meeting:, Feb. 16, 2010 , in conjunction with American Fence Association, FENCETECH 2010, Orlando, Fla., Technical Contact:, Charles Naegele, P.E., Allied Consulting Inc., Clarks Summit, Pa., Phone: 570-586-7260; canaegele@aol.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8427/Dec2009
-
Residual accelerator chemicals in medical gloves appear to be a leading cause of allergic contact dermatitis in health care workers. A new ASTM International standard allows rubber glove manufacturers to monitor the level of residual chemicals in their end products and to potentially make manufacturing changes to reduce allergen levels. The new standard, D7558 , Test Method for Colorimetric/…
-
ASTM International Subcommittee E34.50 on Health and Safety Standards for Metalworking Fluids has developed three new standards. Two of the recently approved ASTM standards cover aspects of water-miscible metalworking fluids, while the third concerns prevention of dermatitis in the wet metal removal fluid environment., Prevention of Dermatitis, Dermatitis is an inflammatory response of the skin to a chemical or physical agent. While redness, swelling and itching are typical signs of dermatitis, symptoms can be more severe as well. A new ASTM standard, ASTM E2693 , Practice for Prevention of Dermatitis in the Wet Metal Removal Fluid Environment, discusses dermatitis and its causes and presents a comprehensive approach to dermatitis…, Metalworking Fluids, Two new E34.50 standards address the detection of microbial contamination in metalworking fluids: ASTM E2657 , Test Method for Determination of Endotoxin Concentrations in Water-Miscible Metalworking Fluids, and ASTM E2694 , Test Method for Measurement of Adenosine Triphosphate in Water-Miscible Metalworking Fluids. Both ASTM E2657 and ASTM E2694 measure biological contamination in metalworking…, Participation Invited, The subcommittee is currently looking for participants for an interlaboratory study for ASTM E2657 and ASTM E2694 . “We plan to use a single set of MWF for both standards, so labs who are interested in either or both are welcome to participate,” says Passman. “A few labs will run both the ILS’s for both standards, while most will run one or the other.” Subcommittee E34.50 is part of ASTM…
-
Once approved, a proposed new ASTM standard would provide the U.S. Food and Drug Administration and personal lubricant manufacturers a means to evaluate the effect of a lubricant on the physical integrity of condoms. No standard currently exists for this type of testing. Manufacturers of condoms and rubber gloves as well as personal lubricants are welcome to join in the development of ASTM…
-
The growing number and severity of healthcare association infections has increased interest in standardization efforts for antimicrobial gloves. In order to explore this area, ASTM International Committee D11 on Rubber has created a new task group on antimicrobial medical gloves. Glove suppliers, manufacturers and distributors, as well as contract test labs, government agency…
-
All interested parties in the glass industry are invited to participate in the development of a proposed new standard guide for the safe handling of annealed glass. The new standard will be developed by a task group within ASTM Committee E34 on Occupational Health and Safety. A small group from industry and OSHA met in Rossford, Ohio, in March to discuss this new activity. The task group plans to…
-
Responding to requests from the food service industry, ASTM International Committee D11 on Rubber has developed and approved a new standard, D7329 , Specification for Food Preparation and Food Handling (Food Service) Gloves. The new standard, under the jurisdiction of Subcommittee D11.40 on Consumer Rubber Products, will serve as a referee and guide to glove manufacturers, distributors and the…
-
A proposed new ASTM International practice will allow a wide variety of users to differentiate levels of effectiveness among the many types of security fence systems that currently exist. WK19721 , Practice for Evaluation of the Effectiveness of Different Types of Fence Systems, is under the jurisdiction of Subcommittee F14.50 on High Security Fences and Perimeter Barriers, part of ASTM…
-
A new ASTM International standard provides instructions for developing the chain-link fence design, layout and installation for a wide variety of sports and recreational facilities and other applications. The standard, F 2631 , Practice for Installation of Chain-Link Fence for Outdoor Sports Fields, Sports Courts and Other Recreation Facilities, was developed by Subcommittee F14.10 on Specific…
-
Testing for potent allergens in rubber is the purpose of a proposed new ASTM standard. WK16334 , Test Method for the Immunological Measurement of Four Principal Allergenic Protein (Hev b 1, 3, 5 and 6.02) in Natural Rubber and Its Products, is being developed by Subcommittee D11.40 on Consumer Rubber Products, part of ASTM International Committee D11 on Rubber. According to Timo Palosuo and…