Search
Advanced search
Filter by category
Filter by committee
Search results
-
Residual accelerator chemicals in medical gloves appear to be a leading cause of allergic contact dermatitis in health care workers. A new ASTM International standard allows rubber glove manufacturers to monitor the level of residual chemicals in their end products and to potentially make manufacturing changes to reduce allergen levels. The new standard, D7558 , Test Method for Colorimetric/…
-
Once approved, a proposed new ASTM standard would provide the U.S. Food and Drug Administration and personal lubricant manufacturers a means to evaluate the effect of a lubricant on the physical integrity of condoms. No standard currently exists for this type of testing. Manufacturers of condoms and rubber gloves as well as personal lubricants are welcome to join in the development of ASTM…
-
No industry standard currently exists that addresses the vacuum sealing requirements of knife-edged flanges for high vacuum applications. Existing international standards focus on interchangeability of the hardware, but do not address the reliability of the seal. ASTM International Committee E42 on Surface Analysis is now working on a proposed standard on the subject, WK21206 , Specification…
-
A 2002 workshop on galling wear held by ASTM International Committee G02 on Wear and Erosion provided the impetus for the development of a new standard, ASTM G196 , Test Method for Galling Resistance of Material Couples. The new standard is under the jurisdiction of Subcommittee G02.40 on Non-Abrasive Wear. According to Scott Hummel, Ph.D., associate professor, head of the department of…
-
The growing number and severity of healthcare association infections has increased interest in standardization efforts for antimicrobial gloves. In order to explore this area, ASTM International Committee D11 on Rubber has created a new task group on antimicrobial medical gloves. Glove suppliers, manufacturers and distributors, as well as contract test labs, government agency…
-
Analysts in laboratories that use regression-based methods to determine uncertainty in data and customers that request such measurements will be the primary users of a new standard recently approved by ASTM International Committee D19 on Water. ASTM D7366 , Practice for Estimation of Measurement Uncertainty for Data from Regression-Based Methods was developed by Subcommittee D19.02 on Quality…
-
Responding to requests from the food service industry, ASTM International Committee D11 on Rubber has developed and approved a new standard, D7329 , Specification for Food Preparation and Food Handling (Food Service) Gloves. The new standard, under the jurisdiction of Subcommittee D11.40 on Consumer Rubber Products, will serve as a referee and guide to glove manufacturers, distributors and the…
-
Testing for potent allergens in rubber is the purpose of a proposed new ASTM standard. WK16334 , Test Method for the Immunological Measurement of Four Principal Allergenic Protein (Hev b 1, 3, 5 and 6.02) in Natural Rubber and Its Products, is being developed by Subcommittee D11.40 on Consumer Rubber Products, part of ASTM International Committee D11 on Rubber. According to Timo Palosuo and…
-
Cyanide is routinely analyzed in water samples, often to demonstrate regulatory compliance; however, improper sample collection or pretreatment can result in significant positive or negative bias potentially resulting in unnecessary permit violations or undetected cyanide releases into the environment. Because of the importance and timeliness of these issues, ASTM Subcommittee D19.06 on Methods…
-
While nearly all of the instrumentation employed in the field to measure radioactive materials or radiation exposure rates used to be in the hands of state radiological control agencies or federal government national response organizations, this is no longer the case. Now, law enforcement personnel, first responders and other professionals have radiation detection instruments, though they may not…