Search
Advanced search
Filter by category
Filter by committee
Search results
-
Natural gas from unconventional sources such as coal beds has become a common target of exploration. Now, a new ASTM standard is the first to describe a method for determining the gas content of coal from such sources by desorption, using samples obtained by surface drilling. ASTM D7569 , Practice for Determination of Gas Content of Coal - Direct Desorption Method, was developed by Subcommittee…, ASTM Committee D05 Next Meeting:, May 15-18, 2011, May Committee Week, Anaheim, Calif., Technical Contact:, Peter Warwick, U.S. Geological Survey, Reston, Va., Phone: 703-648-6469; pwarwick@usgs.gov, ASTM Staff Contact:, Scott Orthey, Phone: 610-832-9730; sorthey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8749
-
A new ASTM subcommittee seeks to acknowledge the ongoing advances being made in the field of nanostructured inorganic coatings. B08.16 on Nanostructured Coatings, part of ASTM International Committee B08 on Metallic and Inorganic Coatings, is currently developing its first proposed standard, ASTM WK29468 , Specification for Galvanic Protection of Steel Using a Nanostructured Coating of 95 % Zinc…
-
A proposed new ASTM International standard will assist users of cyanide analysis methods who want to work in compliance with the International Cyanide Management Code. The Code covers the proper handling of cyanide from production, transportation to processing sites and design of cyanide facilities, including detoxification, storage and release of excess cyanide processing waters. ASTM WK27288 ,…
-
Moisture, volatile matter and ash are three of the primary parameters used for assessing the quality of coal. A new ASTM standard that covers the use of a macro thermogravimetric analyzer for the determination of moisture, volatile matter and ash in analysis samples of coal and coke has recently been approved by ASTM International Committee D05 on Coal and Coke. ASTM D7582 , Test Methods for…, ASTM Committee D05 Next Meeting:, May 16-19, May committee week, St. Louis, Mo., Technical Contact:, John T. Riley, Ph.D., Western Kentucky University, Bowling Green, Ky., Phone: 270-842-2757; brgrileys@insightbb.com, ASTM Staff Contact:, Scott Orthey, Phone: 610-832-9730; sorthey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8 508/Feb2010
-
In an action effective on Nov. 10, 2009, 15 methods contained in 10 ASTM standards are among 25 analytical methods that the U.S. Environmental Protection Agency has approved for determining contaminant concentrations in samples collected under the Safe Drinking Water Act. The methods are under the jurisdiction of Subcommittee D19.05 on Inorganic Constituents in Water, part of ASTM Committee D19…, ASTM Committee D19 Next Meeting:, Jan. 17-21, Cocoa Beach, Fla., ASTM Staff Contact:, Brynn Murphy , Phone: 610-832-9640; bmurphy@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #84 52/Jan2010
-
ASTM International Subcommittee E34.50 on Health and Safety Standards for Metalworking Fluids has developed three new standards. Two of the recently approved ASTM standards cover aspects of water-miscible metalworking fluids, while the third concerns prevention of dermatitis in the wet metal removal fluid environment., Prevention of Dermatitis, Dermatitis is an inflammatory response of the skin to a chemical or physical agent. While redness, swelling and itching are typical signs of dermatitis, symptoms can be more severe as well. A new ASTM standard, ASTM E2693 , Practice for Prevention of Dermatitis in the Wet Metal Removal Fluid Environment, discusses dermatitis and its causes and presents a comprehensive approach to dermatitis…, Metalworking Fluids, Two new E34.50 standards address the detection of microbial contamination in metalworking fluids: ASTM E2657 , Test Method for Determination of Endotoxin Concentrations in Water-Miscible Metalworking Fluids, and ASTM E2694 , Test Method for Measurement of Adenosine Triphosphate in Water-Miscible Metalworking Fluids. Both ASTM E2657 and ASTM E2694 measure biological contamination in metalworking…, Participation Invited, The subcommittee is currently looking for participants for an interlaboratory study for ASTM E2657 and ASTM E2694 . “We plan to use a single set of MWF for both standards, so labs who are interested in either or both are welcome to participate,” says Passman. “A few labs will run both the ILS’s for both standards, while most will run one or the other.” Subcommittee E34.50 is part of ASTM…
-
Measuring the reflectance of vitrinite dispersed in sedimentary rocks is one of the most commonly used tools for determining thermal maturity in hydrocarbon exploration, basin modeling and other geological applications. Despite this, there currently is not a consensus standard for making these measurements. ASTM International Committee D05 on Coal and Coke is developing a proposed standard to…
-
Subcommittee D05.21 on Methods of Analysis invites all interested parties to participate in the development of a proposed new standard, WK22936 , Test Method for Determination of Sulfur Forms in Coal by ICP-AES. The subcommittee is part of ASTM International Committee D05 on Coal and Coke. According to Colin Campbell, SaskPower, and D05 member, WK22936 is to be based on D2492 , Test Method for…
-
A new mechanical sampling standard recently approved by ASTM International Committee D05 on Coal and Coke incorporates into one document four other ASTM standards dealing with mechanical samples. The new standard, D7430 , Practice for Mechanical Sampling of Coal, is under the jurisdiction of Subcommittee D05.23 on Sampling. Paul Reagan, president, Sampling Associates International, and a D05…
-
Analysts in laboratories that use regression-based methods to determine uncertainty in data and customers that request such measurements will be the primary users of a new standard recently approved by ASTM International Committee D19 on Water. ASTM D7366 , Practice for Estimation of Measurement Uncertainty for Data from Regression-Based Methods was developed by Subcommittee D19.02 on Quality…