ASTM International’s Committee on Copper and Copper Alloys (B05) has presented its top annual award – the Award of Merit – to Andrew Kireta, Jr. of the Copper Development Association, Inc. in Franklin, Ind., U.S.A. The prestigious award, which includes the accompanying title of fellow, is ASTM’s highest recognition for individual contributions to developing standards. The committee honored Kireta…, Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org Release #10075
-
Charles B. Blanton, corporate director of environmental, healthy and safety, Mueller Industries, Inc., Memphis, Tenn., has been named chairman of ASTM International Committee B05 on Copper and Copper Alloys . Formed in 1928, B05 has over 210 members representing 9 countries, and includes 12 technical subcommittees that oversee 150 standards related to the development of qualifications data and…, Media Inquiries:, Dan Bergels, tel +1.610.832.9602; dbergels@astm.org Release #10054
-
A proposed new ASTM International standard will aid in understanding thermal transport properties, an important component in optimizing the energy efficiency of building materials and improving thermal design in electronics, fuel cells and batteries. The test described in ASTM WK46204, Test Method for Determination of Thermal Conductivity and Thermal Diffusivity of Solids and Fluids Using the…, ASTM Committee E37 Next Meeting:, Aug. 29, University of Delaware Center for Composite Materials, Newark, Del., Technical Contact:, Mattias Gustavsson, Ph.D., Hot Disk AB, Gothenburg, Sweden, Phone: +46-31-411-410; mattias.gustavsson@hotdiskinstruments.com , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9629
-
Solid, round, fine wire is often used by the medical industry in devices such as catheter guide wires, stents for the repair of arteries and containment vessels such as vena cava filters. A new ASTM International standard, ASTM E2948 , Test Method for Conducting Rotating Bending Fatigue Tests of Solid Round Fine Wire, will be used to determine the fatigue life characteristics of such wire in…, ASTM Committee E08 Next Meeting:, Nov. 10-13, 2014, November Committee Week, New Orleans, La., Technical Contact:, K.L. Jerina, Washington University, St. Louis, Mo., Phone: 314-935-4960; jerinak@seas.wustl.edu ; and M.R. Mitchell, Mechanics and Materials Consulting LLC, Flagstaff, Ariz., mrmitchell@illinoisalumni.org , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9613
-
A new ASTM International standard will enable fracture toughness testing on defects that are directly analogous to those commonly found in structural applications. ASTM E2899 , Test Method for Measurement of Initiation Toughness in Surface Cracks under Tension and Bending, was developed by Subcommittee E08.07 on Fracture Mechanics , part of ASTM International Committee E08 on Fatigue and Fracture…, ASTM Committee E08 Next Meeting:, Nov. 11-14, 2013, November Committee Week, Jacksonville, Fla., Technical Contact:, Douglas N. Wells, NASA-MSFC, Huntsville, Ala., Phone: 256-544-3300; douglas.n.wells@nasa.gov, ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9507
-
Rotational viscometry is an easily used tool for determining the viscosity of fluids, including paints, petroleum products and polymer solutions. While standards often make use of rotational viscometry, a procedure for calibrating or validating the measurement is not always part of the standard, which could lead to results that differ from one laboratory to another. A proposed user viscosity…, ASTM Committee E37 Next Meeting:, March 14, 2014, ASTM International Headquarters, West Conshohocken, Pa., Technical Contact:, Roger Blaine, Corvallis, Ore., Phone: 302-559-6827; roger.l.blaine@gmail.com, ASTM Staff Contact:, Tom O'Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9493
-
Three proposed ASTM International standards will provide a base for the evaluation of the antimicrobial efficacy of solid copper materials. The proposed standards are being developed by Subcommittee B05.06, Methods of Test, part of ASTM International Committee B05 on Copper and Copper Alloys . The three proposed standards are: • ASTM WK42235 , Test Method for Efficacy of Copper Alloy Surfaces as…, ASTM Committee B05 Next Meeting:, Oct. 21-23, 2013, October Committee Week, Jacksonville, Fla., Technical Contact:, James H. Michel, Copper Development Association Inc., New York, N.Y., Phone: 212-251-7210; j ames.michel@copperalliance.us, ASTM Staff Contact:, Jennifer Rodgers, Phone: 610-832-9694; jrodgers@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9439
-
A newly approved ASTM copper standard focuses on the mechanical properties of machining brasses. ASTM B981/B981M , Specification for Low Leaded Brass Rod, Bar and Shapes, was developed by Subcommittee B05.02 on Rod, Bar, Wire, Shapes and Forgings , part of ASTM International Committee B05 on Copper and Copper Alloys . “Since 1997, there has been increasing legislation, regulation and voluntary…, ASTM Committee B05 Next Meeting:, April 15-17, 2013, April Committee Week, Indianapolis, Ind., Technical Contact:, Larry Muller, Chase Brass and Copper Co., Montpelier, Ohio, Phone: 419-485-8932; lmuller@chasebrass.com, ASTM Staff Contact:, Jennifer Rodgers, Phone: 610-832-9694; jrodgers@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9307
-
Richard W. Neu, Ph.D., a professor in the Wodruff School of Mechanical Engineering at the Georgia Institute of Technology in Atlanta, Ga., has received the ASTM International Award of Merit from Committee E08 on Fatigue and Fracture . The Award of Merit and its accompanying title of fellow is ASTM’s highest organizational recognition for individual contributions to standards activities. Neu, who…
-
Rheologists are encouraged to join in the development of a proposed new practice that will help standardize calibration of rotational rheometers to obtain accurate normal force measurements. ASTM WK33687 , Practice for Normal Force Calibration for Rotational Rheometers, is being developed by Subcommittee E37.08 on Rheology , part of ASTM International Committee E37 on Thermal Measurements . The…, ASTM Committee E37 Next Meeting:, Aug. 10-11, in conjunction with the North American Thermal Analysis Society Annual Conference, Des Moines, Iowa, Technical Contact:, Kenneth Aniunioh, Shimadzu Scientific Instruments, Laurel, Md., Phone: 864-633-7690; kenebaano@yahoo.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8923