Search
Advanced search
Filter by category
Filter by committee
Search results
-
A new ASTM International standard will provide an industrywide practice for inspecting long lengths of above ground steel pipework using guided wave testing. ASTM E2775 , Practice for Guided Wave Testing of Above Ground Steel Pipework Using Piezoelectric Effect Transduction, is under the jurisdiction of Subcommittee E07.10 on Specialized NDT Methods , part of ASTM International Committee E07 on…, ASTM Committee E07 Next Meeting:, Jan. 22-26, 2012, Plantation, Fla., Technical Contact:, Jimmy Fong, Guided Ultrasonics Ltd., Brentford, Great Britain, Phone: +011-44-0-45-605-0227; jimmy@guided-ultrasonics.com, ASTM Staff Contact:, Kathleen McClung, Phone: 610-832-9717; kmcclung@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #8993
-
The importance of digital detector array technology is increasing as industry continues its transition from film radiography to the digital realm. Subcommittee E07.01 on Radiology (X and Gamma) Method, part of ASTM International Committee E07 on Nondestructive Testing, has recently approved the following three new standards that will aid users in the film-to-digital transition: • ASTM E2698 ,…
-
ASTM International Committee E07 on Nondestructive Testing has recently approved three new standards on phased arrays, polymer matrix composites for aerospace applications and digital imaging. The committee will be meeting in Plantation, Fla., on Jan. 24-28 and welcomes participation in its standards developing activities., Ultrasonic Methods, Thousands of portable phased array units, used for weld inspections, have now been sold worldwide. There are many benefits to these devices, including speed, cost, imaging, flexibility and setups, along with no radiation, licensing or contamination. Despite these advantages, there was not a universal inspection procedure for phased array inspection of welds. A new standard, E2700 , Practice for…, Specialized NDT Methods, A new guide gives an introductory overview that describes how mature and established nondestructive testing methods that are routinely used by industry are applied specifically to the characterization of polymer matrix aerospace composites. E2533 , Guide for Nondestructive Testing of Polymer Matrix Composites Used in Aerospace Applications, is under the jurisdiction of Subcommittee E07.10 on…, Digital Imaging and Communication in Nondestructive Evaluation, A new standard developed by Subcommittee E07.11 on Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) will fill a need in the nondestructive testing industry for a transparent and industry standard data format with which to store digital inspection data. E2663 , Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) for Ultrasonic Test Methods…, WK17435,, Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) for X-Ray Computed Tomography (CT) Test Methods;, WK17436, , Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) for Digital Radiographic (DR) Test Methods;, WK20537, , Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) for Eddy Current Test Methods; and, WK22505,, Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) for Computed Radiography (CR) Test Methods. ASTM International standards can be purchased from Customer Service (phone: 610-832-9585; https://www.astm.org/contact/ ). ASTM International welcomes and encourages participation in the development of its standards. For more information on becoming an ASTM member, visit www.astm.…, ASTM Committee E07 Next Meeting:, Jan. 24-28 , Plantation, Fla., Technical Contacts: (E2700), Michael Moles, Olympus NDT, Waltham, Mass., Phone: 416-831-4428; michael.moles@olympusndt.com ;, (E2533), Jess Waller, NASA White Sands Facility, Las Cruces, N.M., Phone: 575-524-5249; jess.m.waller@nasa.gov ; , (E2663), Patrick Howard, GE Aviation, Cincinnati, Ohio, Phone: 513-552-4646; patrick.howard@ge.com, ASTM Staff Contact:, George Luciw, Phone: 610-832-9710; gluciw@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8431/Dec2009
-
A series of standards on nondestructive inspection and examination of aerospace composites has been developed under the jurisdiction of ASTM International Committee E07 on Nondestructive Testing. Several years ago, with impetus and input from representatives of the National Aeronautics and Space Administration, a task group on NDE for Aerospace Composites was formed under Subcommittee E07.10 on…
-
A new ASTM International standard will have applications in a variety of factories, on artificial turfs and playing surfaces, and even in the classroom. The new standard, G194 , Test Method for Measuring Rolling Friction Characteristics of a Spherical Shape on a Flat Horizontal Surface, was developed by Subcommittee G02.50 on Friction, part of ASTM International Committee G02 on Wear and Erosion…
-
Nondestructive testing equipment manufacturers and users are invited to join a task group developing a proposed new ASTM standard, WK20537 , Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) for Eddy Current Test Methods. The proposed practice, which will focus on test results storage and communication, will be based on a highly successful medical industry…
-
Testing the oxygen permeation of packaging material is important for the suppliers of various barrier materials, as well as users of these materials in the food, pharmaceutical and consumer product companies, universities, research organizations and other industries. This kind of testing is covered in a new ASTM International standard approved by Committee F02 on Flexible Barrier Packaging, F2622…
-
ASTM International Committee B05 on Copper and Copper Alloys has created a new task group, TG9018, which will be focused on the Antimicrobial Applications of Copper and Copper Alloys. The task group was formed following the U.S. Environmental Protection Agency's announcement of its registration of copper alloys as antimicrobial materials with specific health claims. According to James Michel,…
-
Sterilized medical devices are indispensable to doctors and surgeons around the world. Peel pouches, otherwise known as preformed sterile barrier systems, are used to keep these devices sterile during all physical handling. These pouches can be made with a wide variety of material and are produced by many different suppliers, but the trait all pouches must share is the ability to protect devices…
-
ASTM International Committee E07 on Nondestructive Testing has approved a new standard that can be used for the same applications as the now-cancelled MIL-STD-2154, Process for Inspection, Ultrasonic, Wrought Metals. The new standard, E 2375 , Practice for Ultrasonic Examination of Wrought Products, is under the jurisdiction of Subcommittee E07.06 on Ultrasonic Testing Procedures. Practice E…