Search
Advanced search
Filter by category
Filter by committee
Search results
-
A new ASTM International standard ( F2697 , Test Methods for Physical Assault on Overhead Horizontal Fixed Barriers for Detention and Correctional Facilities) will help ensure that the ceilings of rooms in correctional facilities can withstand breakthrough attempts. The standard aims to promote the safety and security of facility staff, facility residents and the general public. This is the…, Technical Contact:, James A. Stapleton Jr., P.E., Habersham Metal Products Co., tel +1.706.778.2212, ext. 202; jas@habershammetal.com, ASTM Staff Contact:, Joseph Hugo, tel +1.610.832.9740; jhugo@astm.org, ASTM PR Contact:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org Release #9770
-
Fiber-reinforced polymers are used to strengthen concrete, wood and steel structures above and below ground as well as under water. Two proposed new ASTM International standards will provide an approach to quality control inspection and reporting for fiber-reinforced polymers in all industries. The proposed new standards are: ASTM WK46050, Guide for the Inspection of Bond Critical FRP…, Next Committee D33 Meeting:, Jan. 15-16, 2015, in conjunction with Electric Power Research Institute/Nuclear Utility Coatings Council meetings, Orlando, Fla., Technical Contact:, Ramon Pelaez, Greenman Pedersen Inc., Southbridge, Mass., Phone: 508-612-5769; rpelaez@gpinet.com, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9624
-
A new ASTM International standard will be used to provide a uniform international method for recording occupational injuries and illnesses, in order to make global performance comparisons of companies in keeping workers safe. ASTM E2920 , Guide for Recording Occupational Injuries and Illnesses, was developed by Subcommittee E34.80 on Industrial Health , part of ASTM International Committee E34 on…, ASTM Committee E34 Next Meeting:, Oct. 8-9, 2014, October Committee Week, New Orleans, La., Technical Contacts:, Thomas J. Slavin, Cardno ChemRisk, Chicago, Ill., Phone: 312-863-2350; tom.slavin@cardno.com; and Steve Newell, ORCHSE Strategies LLC, Washington, D.C., Phone: 202-510-0513; steve.newell@hseorc.com , ASTM Staff Contact:, Kevin Shanahan, Phone: 610-832-9737; kshanahan@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9605
-
Three proposed ASTM International standards will provide a base for the evaluation of the antimicrobial efficacy of solid copper materials. The proposed standards are being developed by Subcommittee B05.06, Methods of Test, part of ASTM International Committee B05 on Copper and Copper Alloys . The three proposed standards are: • ASTM WK42235 , Test Method for Efficacy of Copper Alloy Surfaces as…, ASTM Committee B05 Next Meeting:, Oct. 21-23, 2013, October Committee Week, Jacksonville, Fla., Technical Contact:, James H. Michel, Copper Development Association Inc., New York, N.Y., Phone: 212-251-7210; j ames.michel@copperalliance.us, ASTM Staff Contact:, Jennifer Rodgers, Phone: 610-832-9694; jrodgers@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9439
-
A newly approved ASTM copper standard focuses on the mechanical properties of machining brasses. ASTM B981/B981M , Specification for Low Leaded Brass Rod, Bar and Shapes, was developed by Subcommittee B05.02 on Rod, Bar, Wire, Shapes and Forgings , part of ASTM International Committee B05 on Copper and Copper Alloys . “Since 1997, there has been increasing legislation, regulation and voluntary…, ASTM Committee B05 Next Meeting:, April 15-17, 2013, April Committee Week, Indianapolis, Ind., Technical Contact:, Larry Muller, Chase Brass and Copper Co., Montpelier, Ohio, Phone: 419-485-8932; lmuller@chasebrass.com, ASTM Staff Contact:, Jennifer Rodgers, Phone: 610-832-9694; jrodgers@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9307
-
Accidents involving the handling of annealed glass have heightened interest in standards that could improve safety in the glass industry. In response, ASTM International Committee E34 on Occupational Health and Safety has approved a new standard, ASTM E2875/E2875M , Guide for Personal Protective Equipment for the Handling of Flat Glass. The new standard was developed by Subcommittee E34.35 on…, ASTM Committee E34 Next Meeting:, Oct. 24-25, 2012, October committee week, Atlanta, Ga., Technical Contact:, Michael Marsala, Guardian Industries Corp., Auburn Hills, Mich., Phone: 248-340-2322; mmarsala@guardian.com, ASTM Staff Contact:, Kevin Shanahan, Phone: 610-832-9737; kshanahan@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9257
-
While the quality of coating materials for buried pipe at nuclear power plants has evolved over time, there is currently no written standard that would allow plants to fully take advantage of advances in coating technology. A proposed new standard will provide coating guidance for plants seeking to repair or replace buried pipe. The proposed standard, ASTM WK36282 , Guide for Selection of Coating…
-
A new ASTM International subcommittee has been created to develop standards that will be meaningful and accurate performance indicators to measure work-related injury and illness performance throughout the world. Subcommittee E34.55 on Occupational Safety and Health Performance Improvement is under the jurisdiction of ASTM International Committee E34 on Occupational Health and Safety. “Measuring…
-
ASTM International Subcommittee E34.50 on Health and Safety Standards for Metalworking Fluids has developed three new standards. Two of the recently approved ASTM standards cover aspects of water-miscible metalworking fluids, while the third concerns prevention of dermatitis in the wet metal removal fluid environment., Prevention of Dermatitis, Dermatitis is an inflammatory response of the skin to a chemical or physical agent. While redness, swelling and itching are typical signs of dermatitis, symptoms can be more severe as well. A new ASTM standard, ASTM E2693 , Practice for Prevention of Dermatitis in the Wet Metal Removal Fluid Environment, discusses dermatitis and its causes and presents a comprehensive approach to dermatitis…, Metalworking Fluids, Two new E34.50 standards address the detection of microbial contamination in metalworking fluids: ASTM E2657 , Test Method for Determination of Endotoxin Concentrations in Water-Miscible Metalworking Fluids, and ASTM E2694 , Test Method for Measurement of Adenosine Triphosphate in Water-Miscible Metalworking Fluids. Both ASTM E2657 and ASTM E2694 measure biological contamination in metalworking…, Participation Invited, The subcommittee is currently looking for participants for an interlaboratory study for ASTM E2657 and ASTM E2694 . “We plan to use a single set of MWF for both standards, so labs who are interested in either or both are welcome to participate,” says Passman. “A few labs will run both the ILS’s for both standards, while most will run one or the other.” Subcommittee E34.50 is part of ASTM…
-
ASTM International Committee B05 on Copper and Copper Alloys has created a new task group, TG9018, which will be focused on the Antimicrobial Applications of Copper and Copper Alloys. The task group was formed following the U.S. Environmental Protection Agency's announcement of its registration of copper alloys as antimicrobial materials with specific health claims. According to James Michel,…