Search
Advanced search
Filter by category
Filter by committee
Search results
-
A new ASTM International standard will support the sustainability and resiliency of concrete pipes that are reinforced by synthetic fibers. The new standard (soon to be approved as C1818, Specification for Rigid Synthetic Fiber Reinforced Concrete Culvert, Storm Drain and Sewer Pipe) describes a strong and durable option that can be used for underground piping. Pipes in this new standard are used…, ASTM Committee C13 on Concrete Pipe Next Meeting:, Nov. 15-18, 2015, November Committee Week, Tampa, Fla., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Ali Abolmaali, University of Texas, Arlington, Texas, tel +1.817.272.3877; abolmaail@uta.edu, ASTM Staff Contact:, Diane Lake, tel +1.610.832.9661; dlake@astm.org Release #9940
-
A new ASTM International standard provides a rigorous test for evaluating certain parts of next-generation nuclear power plants which incorporate new materials and technologies. Specifically, the new standard (C1819, Test Method for Hoop Tensile Strength of Continuous Fiber-Reinforced Advanced Ceramic Composite Tubular Test Specimens at Ambient Temperature Using Elastomeric Inserts) will test…, Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Michael G. Jenkins Ph.D., P.E., Bothell Engineering and Science Technologies, tel +1.425.876.7061; jenkinsmg@bothellest.com Release #9925
-
Precast reinforced concrete box sections are proving to be a versatile means for the development of infrastructure. The use of segmental box sections is now covered in an ASTM standard, ASTM C1786 , Specification for Segmental Precast Reinforced Concrete Box Sections for Culverts, Storm Drains and Sewers Designed According to AASHTO LRFD. The American Association of State Highway and…, Technical Contact:, Josiah W. Beakley, American Concrete Pipe Association, Irving, Texas, tel +1.972.894.2906; jbeakley@concrete-pipe.org, ASTM Staff Contact:, Diane Lake, tel +1.610.832.9661; dlake@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9745
-
Three proposed ASTM International standards will provide a base for the evaluation of the antimicrobial efficacy of solid copper materials. The proposed standards are being developed by Subcommittee B05.06, Methods of Test, part of ASTM International Committee B05 on Copper and Copper Alloys . The three proposed standards are: • ASTM WK42235 , Test Method for Efficacy of Copper Alloy Surfaces as…, ASTM Committee B05 Next Meeting:, Oct. 21-23, 2013, October Committee Week, Jacksonville, Fla., Technical Contact:, James H. Michel, Copper Development Association Inc., New York, N.Y., Phone: 212-251-7210; j ames.michel@copperalliance.us, ASTM Staff Contact:, Jennifer Rodgers, Phone: 610-832-9694; jrodgers@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9439
-
, ASTM to Partner with ASC to Foster EPD Development, ASTM International will be collaborating with industry to develop Environmental Product Declarations (EPDs) across the 90+ industry markets they support, including sealants. The Adhesive and Sealant Council (ASC) will be partnering with ASTM International to raise awareness of this effort, educate industry on the value of Type III EPDs, and proactively engage industry in developing Product…, ASTM Staff Contact:, Tim Brooke, Phone: 610-832-9729; tbrooke@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9370
-
Since the late 1970s, precast box sections have become an important component in the construction of culverts, storm drains and sewers, but there has not been a comprehensive standard for the installation of such sections. A new ASTM International standard fills this gap. ASTM C1675, Practice for Installation of Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains and…, Technical Contact:, Roman Selig, Hamilton Kent LLC, Birmingham, Ala., Phone: 205-910-0690; roman.selig@hamiltonkent.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9243
-
Load and resistance factor design methodology developed by the American Association of State Highway and Transportation Officials plays a key role in a proposed ASTM standard on the design of culverts and storm drains. ASTM WK38166 , Specification for Manufacture of Precast Reinforced Concrete Three-Sided Structures for Culverts and Storm Drains Designed According to AASHTO LRFD, is being…, Technical Contact:, Balaram K. Singh, P.E., Michigan Department of Transportation, Lansing, Mich., Phone: 517-335-2174; singhb@michigan.gov, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact, : Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9311
-
A newly approved ASTM copper standard focuses on the mechanical properties of machining brasses. ASTM B981/B981M , Specification for Low Leaded Brass Rod, Bar and Shapes, was developed by Subcommittee B05.02 on Rod, Bar, Wire, Shapes and Forgings , part of ASTM International Committee B05 on Copper and Copper Alloys . “Since 1997, there has been increasing legislation, regulation and voluntary…, ASTM Committee B05 Next Meeting:, April 15-17, 2013, April Committee Week, Indianapolis, Ind., Technical Contact:, Larry Muller, Chase Brass and Copper Co., Montpelier, Ohio, Phone: 419-485-8932; lmuller@chasebrass.com, ASTM Staff Contact:, Jennifer Rodgers, Phone: 610-832-9694; jrodgers@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9307
-
Sealant manufacturers will use a new ASTM International standard to evaluate new products and changes to these products due to exposure to weather. The new standard, ASTM C1735 , Test Method for Measuring the Time Dependent Modulus of Sealants Using Stress Relaxation, is under the jurisdiction of Subcommittee C24.20 on General Test Methods , part of ASTM International Committee C24 on Building…, ASTM Committee C24 Next Meeting:, Jan. 8-10, 2012, Ft. Lauderdale, Fla., Technical Contact:, Christopher C. White, Ph.D., National Institute of Standards and Technology, Gaithersburg, Md., Phone: 301-975-6016; christopher.white@nist.gov, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9005
-
ASTM International Committee C13 on Concrete Pipe has approved a new standard that covers flexible joints for concrete box sections using rubber gaskets for leak resistant joints. Subcommittee C13.08 on Joints for Precast Concrete Structures developed ASTM C1677 , Specification for Joints for Concrete Box, Using Rubber Gaskets. “This specification will provide a uniform minimum level of…