Search
Advanced search
Filter by category
Filter by committee
Search results
-
Subjects Include Vented Construction Systems, Furnace Exposure and Tunnel Fire Resistance, Subcommittee E05.11 on Fire Resistance, part of ASTM International Committee E05 on Fire Standards, is currently developing a number of proposed standards, including the following three test methods on vented construction systems, furnace exposure on test samples and tunnel fire resistance. All parties interested in working on fire resistance standards are encouraged to join in the activities of…, Vented Construction, Understanding how construction systems will perform in the earliest moments of a fire is crucial. A proposed new ASTM standard, WK22660 , Test Method for Evaluating Fire Performance of Vented Construction, will provide tests for evidence on how vented construction systems are affected by the first five minutes of a fire and will be used to complement existing fire testing methods test results “…, Furnace Exposure, Fire test laboratories and fire protection engineers will be the primary users of proposed new standard ASTM WK23795 , Test Method for Measuring the Uniformity of Furnace Exposure on Test Samples. The proposed standard provides general principles for measuring the uniformity of furnace exposure on samples tested in accordance with the following standards: - ASTM E119 , Test Methods for Fire…, Tunnel Fire Resistance, Fires in tunnels can reach temperatures as high as 2,500°F [1371°C], but current standards that deal with building fires provide for a maximum temperature of 2,000°F [1093°C] and are not specific to tunnels. A proposed new standard, ASTM WK23821 , Test Methods for Tunnel Fire Resistance, will be developed with the special considerations of tunnel fires in mind. According to Barry Badders, manager…
-
The U.S. Environmental Protection Agency has determined that the 2008 revision to an ASTM International standard describing the environmental assessment needs of parties involved in the acquisition of forestland and rural properties is now compliant with the agency’s All Appropriate Inquiries Rule (40 CFR Part 312, Standards and Practices for All Appropriate Inquires). The EPA decision came in a…
-
The ASTM standard that describes the environmental assessment needs of parties involved in the acquisition of forestland and rural property has been revised. The revision is an important step toward making ASTM E2247 , Practice for Environmental Site Assessments: Phase I Environmental Site Assessment Process for Forestland or Rural Property, compliant with the U.S. Environmental Protection Agency…
-
A proposed new ASTM International standard will provide a definable quality specification for both producers and consumers of secondary Prime Western Grade zinc metal. WK16399 , Specification for Prime Western Grade-Recycled (PWG-R) Zinc Metal Produced from Recycled Zinc Secondary Material, is being developed by Subcommittee B02.04 on Zinc and Cadmium, part of ASTM International Committee B02 on…
-
Vapor intrusion from contaminated soil and groundwater into structures can potentially create significant liability and have a material impact on property value. Because of this, accurately determining whether a property has vapor intrusion issues is a concern for property owners, prospective purchasers and environmental professionals conducting due diligence. ASTM International Committee E50 on…
-
Information on light nonaqueous-phase liquids and their impact on the environment has grown significantly in the last 20 years. This accumulation of knowledge means that different remediation strategies are now available for sites that contain these substances. In order to facilitate decision making, ASTM International Committee E50 on Environmental Assessment has developed a new standard, E 2531…
-
ASTM International Committee E50 on Environmental Assessment, Risk Management, and Corrective Action is seeking participation in the development of a proposed new standard, WK15256, Guide for Investigation of Petroleum Underground Storage Tank Equipment Problems and Releases. The proposed guide, under the jurisdiction of Subcommittee E50.04 on Corrective Action, is intended to assist with the…
-
A project originally intended to develop a uniform template for the language within a series of standards has resulted in the approval of a new standard, B 949 , Specification for General Requirements for Zinc and Zinc Alloy Products. The new standard is under the jurisdiction of Subcommittee B02.04 on Zinc and Cadmium, which is part of ASTM International Committee B02 on Nonferrous Metals and…
-
Mold, or even the prospect of mold, can create a level of fear and misperception that can have a significant negative impact on all phases of the real estate market. However, in an effort to replace fear with facts, ASTM International’s Committee E50 on Environmental Assessment, Risk Management, and Corrective Action has developed a new standard, E 2418 , Guide for Readily Observable Mold and…
-
An ASTM International environmental assessment standard has recently undergone major revisions to reflect relevant changes in federal law. The standard, E 1528 , Practice for Limited Environmental Due Diligence: Transaction Screen Process, is under the jurisdiction of Subcommittee E50.02 on Real Estate Assessment and Management, which is part of ASTM International Committee E50 on Environmental…