Search
Advanced search
Filter by category
Filter by committee
Search results
-
Overhead conductors used to transmit electricity typically consist of stranded aluminum wires that surround a stranded steel wire core. However, a more recently developed conductor consists of composite materials of carbon and glass fibers that replace the stranded steel-supporting member. This new type of conductor will be covered in a new ASTM International standard, ASTM B987 , Specification…, ASTM Committee B01 Next Meeting:, April 29, 2015, April Committee Week, Anaheim, Calif., Technical Contact:, Eric Bosze, Ph.D., CTC Global, Irvine, Calif., Phone: +1.949.381.7262; ebosze@ctcglobal.com, ASTM Staff Contact:, Kristy Straiton, Phone: +1.610.832.9640; kstraiton@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: +1.610.832.9603; bschindl@astm.org Release #9694
-
Adopted in 2005, Chapter 7A of the California Building Code describes provisions for attic vents for new construction in wildfire-prone areas. While the California code notes that attic vents should resist the intrusion of embers and flames, there had not been a standard to evaluate such intrusion. A new standard, ASTM E2886/E2886M , Test Method for Evaluating the Ability of Exterior Vents to…, ASTM Committee E05 Next Meeting:, Dec. 8-11, 2014, December Committee, New Orleans, La., Technical Contact:, Stephen Quarles, Insurance Institute for Business and Home Safety, Richburg, S.C., Phone: 803-789-4209; squarles@ibhs.org , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9617
-
A proposed new ASTM International standard is being developed for mounting plastic pipe and tube in the Steiner tunnel furnace. The draft procedure will help determine the fire-related properties of the pipe and tube in accordance with ASTM E84, Test Method for Surface Burning Characteristics of Building Materials. ASTM WK44535 , Practice for Mounting of Plastic Pipe, Plastic Tubing, Plastic Pipe…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee, Toronto, Ontario, Canada, Technical Contact:, Joe Zicherman, Fire Cause Analysis, Berkeley, Calif., Phone: 510-649-1300; zicherman46@gmail.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9635
-
A wildland-urban interface is a transitional zone between unoccupied land and human development. There are currently more than 40 million homes located within WUI areas throughout the United States. A proposed new ASTM standard will be used to alleviate the issue of fire conditions that exist due to eaves and other projections in structures that exist in WUI areas. ASTM WK37414, Test Method for…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee Week, Toronto, Ontario, Canada, Technical Contact:, John Simontacchi, Firefree Coatings Inc., San Rafael, Calif., Phone: 415-459-6488; jsimontacchi@firefree.com , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9529
-
ASTM B986 , Test Method for Determination of Tensile Strength by Mass Method for Stranded Conductors Intended for use in Electronic Application, will be used within the electronics and aerospace industries to validate tensile strength specification requirements for electrical conductors. ASTM B986 was developed by Subcommittee B01.02 on Methods of Test and Sampling Procedure , part of ASTM…, ASTM Committee B01 Next Meeting:, Oct. 23, 2013, October Committee Week, Jacksonville, Fla., Technical Contact:, Stephen Childers, IWG High Performance Conductors Inc., Inman, S.C., Phone: 864-472-0438; stephen.childers@iwghpc.com , ASTM Staff Contact:, Kristy Straiton, Phone: 610-832-9640; kstraiton@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9364
-
ASTM International Committee E55 on Manufacture of Pharmaceutical Products is currently developing a proposed standard that will document a set of process steps that can reproducibly inactivate or remove any potential retrovirus in new biological products, particularly antibodies and antibody-like compounds. The proposed standard, ASTM WK39883 , Practice for Process of Inactivation of Enveloped…, ASTM Committee E55 Next Meeting:, April 9-11, 2013, Genzyme-A Sanofi Company, Haverhill, Suffolk, United Kingdom, Technical Contact:, John Schreffler, Ph.D., Morphotek Inc., Exton, Pa., Phone: 610-423-6557; jschreffler@morphotek.com, ASTM Staff Contact:, Christine DeJong, Phone: 610-832-9736; cdejong@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9327
-
A proposed new ASTM International standard will provide an important process step to be used in the manufacture of protein-based drugs, such as antibodies and fusion proteins, made to inactivate retroviruses. The proposed standard, ASTM WK36552 , Practice for Inactivation of Retrovirus by pH, is being developed by Subcommittee E55.04 on General Biopharmaceutical Standards , part of ASTM…
-
A new test method is the latest in a series of ASTM International standards being developed to address the protection of exterior portions of structures during fires. The new standard, ASTM E2726/E2726M , Test Method for Evaluating the Fire-Test-Response of Deck Structures to Burning Brands, is being developed by Subcommittee E05.14 on External Fire Exposures , part of ASTM International…
-
The construction of an unprecedented number of overhead power lines around the world has increased the demand for accurate data and models for electrical conductors. A proposed new standard, ASTM WK35208, Test Methods for Stress-Strain and Creep Testing for Overhead Electrical Conductors, will answer this global need. ASTM WK35208 is being developed by Subcommittee B01.02 on Methods of Test and…
-
A new ASTM standard will provide the United States building codes with a test method designed to test a heating, ventilation and air conditioning duct system or its materials for fire resistance and other durability requirements. ASTM E2816 , Test Methods for Fire Resistive Metallic HVAC Duct Systems, was developed by Subcommittee E05.11 on Fire Resistance , under the jurisdiction of ASTM…