Search
Advanced search
Filter by category
Filter by committee
Search results
-
Activated carbon is processed to have small, low-volume pores that increase the surface area available for adsorption. It has applications in the medical, environmental and energy realms, among others. Since 1962, ASTM International Committee D28 on Activated Carbon has developed standards that play a pre-eminent role in how activated carbon is used. A D28 subcommittee, D28.02 on Liquid Phase…, WK47401, Xylenol Orange Dye, The xylenol orange dye test is a way to determine the relative adsorption rate of unused or reactivated carbons by adsorption of xylenol orange from aqueous solution. This is an important means for deciding which type of activated carbon to use to a specific water treatment application. “Activated carbon performance can roughly be defined as a combination of the ability to adsorb a particular…, WK47421, Particle Size Distribution, Mercury flue gas, home water filters and potable water treatment are the main applications in which powdered and fine mesh carbons are used. A proposed new test method will describe how a laser light scattering technique can determine the particle size distribution of fine mesh activated carbon. ASTM member Neal Megonnell, vice president, sales and marketing, Haycarb USA, says the proposed test…, ASTM Committee D28 Next Meeting:, April 27, April Committee Week, Anaheim, Calif., Technical Contact:, (WK47401) Adam Redding, Ph.D., Evoqua Water Technologies LLC, Northwest, Pa., tel +1.724.719.0805; adam.redding@evoqua.com and (WK47421) Neal E. Megonnell, Haycarb USA, Pittsburgh, Pa., tel +1.412.709.7487; neal@haycarbusa.com, ASTM Staff Contact:, Kelly Paul, tel +1.610.832.9745; kpaul@astm.org, ASTM PR Contact:, Barbara Schindler, tel +1.610.832.9603; bschindl@astm.org Release #9731
-
Overhead conductors used to transmit electricity typically consist of stranded aluminum wires that surround a stranded steel wire core. However, a more recently developed conductor consists of composite materials of carbon and glass fibers that replace the stranded steel-supporting member. This new type of conductor will be covered in a new ASTM International standard, ASTM B987 , Specification…, ASTM Committee B01 Next Meeting:, April 29, 2015, April Committee Week, Anaheim, Calif., Technical Contact:, Eric Bosze, Ph.D., CTC Global, Irvine, Calif., Phone: +1.949.381.7262; ebosze@ctcglobal.com, ASTM Staff Contact:, Kristy Straiton, Phone: +1.610.832.9640; kstraiton@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: +1.610.832.9603; bschindl@astm.org Release #9694
-
Since 2009, the National Fire Protection Association has required arc rated gloves in its NFPA70E, Standard for Electrical Safety in the Workplace. A new ASTM standard will now provide arc rating thermal protective values for gloves, which will allow more gloves to be used inside an arc flash zone when there is no shock hazard. The new standard, ASTM F2675/F2675M , Test Method for Determining Arc…, ASTM Committee F18 Next Meeting:, Oct. 20-23, 2013, Charleston, S.C., Technical Contact:, Hugh Hoagland, ArcWear, Louisville, Ky., Phone: 502-832-9737; hugh@arcwear.com , ASTM Staff Contact:, Kevin Shanahan, Phone: 610-832-9737, kshanahan@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9469
-
ASTM B986 , Test Method for Determination of Tensile Strength by Mass Method for Stranded Conductors Intended for use in Electronic Application, will be used within the electronics and aerospace industries to validate tensile strength specification requirements for electrical conductors. ASTM B986 was developed by Subcommittee B01.02 on Methods of Test and Sampling Procedure , part of ASTM…, ASTM Committee B01 Next Meeting:, Oct. 23, 2013, October Committee Week, Jacksonville, Fla., Technical Contact:, Stephen Childers, IWG High Performance Conductors Inc., Inman, S.C., Phone: 864-472-0438; stephen.childers@iwghpc.com , ASTM Staff Contact:, Kristy Straiton, Phone: 610-832-9640; kstraiton@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9364
-
The construction of an unprecedented number of overhead power lines around the world has increased the demand for accurate data and models for electrical conductors. A proposed new standard, ASTM WK35208, Test Methods for Stress-Strain and Creep Testing for Overhead Electrical Conductors, will answer this global need. ASTM WK35208 is being developed by Subcommittee B01.02 on Methods of Test and…
-
A proposed new standard being developed by ASTM International Committee F18 on Electrical Protective Equipment for Workers will provide guidance to assist in the required testing of live-line tools. ASTM WK33590 , Guide for In-Service Inspection, Maintenance and Electrical Testing of Insulating Tools (Fiberglass-Reinforced Plastic (FPR) and Wooden Live-Line Tools), is under the jurisdiction of…
-
Code words have historically been used in the electrical conductor industry as a simple method of identifying the construction details of an overhead conductor product. A proposed new ASTM standard will list code word names and provide a means to register and publish new code words. ASTM WK28737 , Specification for Electrical Overhead Conductor Code Word Names, is being developed by Subcommittee…, ASTM Committee B01 Next Meeting:, Oct. 13, October Committee Week, San Antonio, Texas, Technical Contact:, Gordon Baker, General Cable, Highland Heights, Ky., Phone: 859-572-8493; gbaker@generalcable.com, ASTM Staff Contact:, Jennifer Rodgers, Phone: 610-832-9694; jrodgers@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8613
-
Silver-, nickel- and tin-coated flat conductors are currently used in a variety of electronic applications, including computer, and in the military and commercial aerospace industries. Despite this use, flat conductors made of these materials are not covered by established standards. ASTM International Committee B01 on Electrical Conductors is now developing the following three standards to cover…, ASTM Committee B01 Next Meeting: , April 21, 2010 , April Committee Week, St. Louis, Mo., Technical Contact:, Stephen Childers, IWG High Performance Conductors Inc., Inman, S.C., Phone: 864-472-9694; stephen.childers@iwghpc.com, ASTM Staff Contact:, Jennifer Rodgers, Phone: 610-832-9694; jrodgers@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8442/Dec2009
-
Mercury emissions from flue gases in coal-fired power plants are a large source of atmospheric mercury in the United States, but no standard for determination of mercury adsorption currently exists. One promising method of controlling these emissions involves the injection of powdered activated carbon into the flue gas. A proposed new ASTM International standard would evaluate the performance of…
-
ASTM International Committee B01 on Electrical Conductors has approved a new standard for tin-coated annealed copper wire. The standard, B965 , Specification for High Performance Tin-Coated Annealed Copper Wire Intended for Electrical and Electronic Application for Solderability, was developed by Subcommittee B01.04 on Conductors of Copper and Copper Alloys . Stephen Childers, process engineer,…