Search
Advanced search
Filter by category
Filter by committee
Search results
-
Gaseous hydrogen fluoride is a harsh respiratory irritant; the inhalation of hydrofluoric acid mists causes severe lung damage in exposed workers. A proposed new ASTM standard, WK38734 , Test Method for the Determination of Particulate Fluorides and Hydrofluoric Acid Using Filter Sampling and Suppressed Ion Chromatography, will be used to prevent overexposure of hydrofluoric acid/hydrogen…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, Dietmar Breuer, IFA, Sankt Augustin, Germany, Phone: +49 (0) 2241 231-2533; dietmar.breuer@dguv.de , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9585
-
While monitoring air quality is important in many situations, a variety of different quantitative passive samplers are available for such work. A proposed new ASTM standard, ASTM WK45755 , Guide for Selection of Quantitative Passive Samplers for Volatile Organic Compounds in Air, will help users decide which air sampler type will best suit their needs. ASTM WK45755 will cover issues such as the…, ASTM Committee D22 Next Meeting:, Oct. 5-8, 2014, October Committee Week, New Orleans, La., Technical Contact:, Nicola Watson, Markes International, Loveland, Ohio, Phone: 513-488-6161; nwatson@markes.com , ASTM Staff Contact:, Jeffrey Adkins, Phone: 610-832-9738; jadkins@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9578
-
ASTM B986 , Test Method for Determination of Tensile Strength by Mass Method for Stranded Conductors Intended for use in Electronic Application, will be used within the electronics and aerospace industries to validate tensile strength specification requirements for electrical conductors. ASTM B986 was developed by Subcommittee B01.02 on Methods of Test and Sampling Procedure , part of ASTM…, ASTM Committee B01 Next Meeting:, Oct. 23, 2013, October Committee Week, Jacksonville, Fla., Technical Contact:, Stephen Childers, IWG High Performance Conductors Inc., Inman, S.C., Phone: 864-472-0438; stephen.childers@iwghpc.com , ASTM Staff Contact:, Kristy Straiton, Phone: 610-832-9640; kstraiton@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9364
-
A new ASTM International standard is focused exclusively on testing soil for asbestos. ASTM D7521 , Test Method for Determination of Asbestos in Soil, was developed by Subcommittee D22.07 on Sampling and Analysis of Asbestos , part of ASTM International Committee D22 on Air Quality . According to Alan Segrave, division manager, laboratory services, Bureau Veritas, and an ASTM D22 member, many…, ASTM Committee D22 Next Meeting:, April 14-17, April Committee Week, Indianapolis, Ind., Technical Contact:, Alan M. Segrave, Bureau Veritas North America Inc., Kennesaw, Ga., Phone: 770-590-6706; alan.segrave@us.bureauveritas.com, ASTM Staff Contact:, David Bradley, Phone: 610-832-9681; dbradley@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9295
-
The construction of an unprecedented number of overhead power lines around the world has increased the demand for accurate data and models for electrical conductors. A proposed new standard, ASTM WK35208, Test Methods for Stress-Strain and Creep Testing for Overhead Electrical Conductors, will answer this global need. ASTM WK35208 is being developed by Subcommittee B01.02 on Methods of Test and…
-
A new ASTM International standard, adopted from an American Concrete Institute test method, will be used to help ensure the safety of construction projects. ASTM C1741 , Test Method for Bleed Stability of Cementitious Post-Tensioning Tendon Grout, is under the jurisdiction of Subcommittee C09.41 on Hydraulic Cement Grouts , part of ASTM International Committee C09 on Concrete and Concrete…
-
Piston ring/liner interface can contribute as much as half the total friction loss in internal combustion engines, with the resulting wear leading to reduced energy efficiency and raised emissions. A new ASTM International standard provides a method to more accurately measure small amounts of wear on curved piston ring segments and their counterfaces after lubricated bench-scale testing. “Coupled…
-
A need for a scientifically based procedure to identify equivalent test severity conditions between a 1.707-m diameter laboratory roadwheel surface and a flat or highway surface for radial pneumatic light truck tires has led to the development and approval of a new ASTM International standard. The new standard, ASTM F2869 , Practice for Radial Light Truck Tires to Establish Equivalent Test…
-
A newly approved standard, ASTM D7338 , Guide for the Assessment of Fungal Growth in Buildings, has been developed to provide a go-to reference for anyone testing for mold in buildings. The new standard was developed by Subcommittee D22.08 on Sampling and Analysis of Mold, part of ASTM International Committee D22 on Air Quality. “The lack of consensus standards in the fungal sampling and analysis…, ASTM Committee D22 Next Meeting:, April 10-13, April Committee Week, Anaheim, Calif., Technical Contact:, Lisa Rogers, Mycometer, Inc., Tampa, Fla., Phone: 813-831-6511; lrogers@mycometer.com, ASTM Staff Contact:, David Bradley, Phone: 610-832-9681; dbradley@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8788
-
ASTM Committee G02 on Wear and Erosion is including a field trip in the plans for its Dec. 8-9 meeting in Jacksonville, Fla. Committee members will be visiting the Tribology Laboratory in the mechanical engineering department at the University of Florida in Gainesville. The Tribology Laboratory is actively involved in a wide variety of tribological research and tribology education projects. The…