Since the late 1970s, precast box sections have become an important component in the construction of culverts, storm drains and sewers, but there has not been a comprehensive standard for the installation of such sections. A new ASTM International standard fills this gap. ASTM C1675, Practice for Installation of Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains and…, Technical Contact:, Roman Selig, Hamilton Kent LLC, Birmingham, Ala., Phone: 205-910-0690; roman.selig@hamiltonkent.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9243
-
Load and resistance factor design methodology developed by the American Association of State Highway and Transportation Officials plays a key role in a proposed ASTM standard on the design of culverts and storm drains. ASTM WK38166 , Specification for Manufacture of Precast Reinforced Concrete Three-Sided Structures for Culverts and Storm Drains Designed According to AASHTO LRFD, is being…, Technical Contact:, Balaram K. Singh, P.E., Michigan Department of Transportation, Lansing, Mich., Phone: 517-335-2174; singhb@michigan.gov, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact, : Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9311
-
The construction of an unprecedented number of overhead power lines around the world has increased the demand for accurate data and models for electrical conductors. A proposed new standard, ASTM WK35208, Test Methods for Stress-Strain and Creep Testing for Overhead Electrical Conductors, will answer this global need. ASTM WK35208 is being developed by Subcommittee B01.02 on Methods of Test and…
-
Sealant manufacturers will use a new ASTM International standard to evaluate new products and changes to these products due to exposure to weather. The new standard, ASTM C1735 , Test Method for Measuring the Time Dependent Modulus of Sealants Using Stress Relaxation, is under the jurisdiction of Subcommittee C24.20 on General Test Methods , part of ASTM International Committee C24 on Building…, ASTM Committee C24 Next Meeting:, Jan. 8-10, 2012, Ft. Lauderdale, Fla., Technical Contact:, Christopher C. White, Ph.D., National Institute of Standards and Technology, Gaithersburg, Md., Phone: 301-975-6016; christopher.white@nist.gov, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9005
-
Quality of materials and proper installation are keys to maintaining the effectiveness, safety and durability of radiant barrier systems used for thermal insulation. Two new ASTM standards will provide important information to both users and installers of radiant barrier systems. The new standards are ASTM C1743 , Practice for Installation and Use of Radiant Barrier Systems (RBS) in Residential…
-
Code words have historically been used in the electrical conductor industry as a simple method of identifying the construction details of an overhead conductor product. A proposed new ASTM standard will list code word names and provide a means to register and publish new code words. ASTM WK28737 , Specification for Electrical Overhead Conductor Code Word Names, is being developed by Subcommittee…, ASTM Committee B01 Next Meeting:, Oct. 13, October Committee Week, San Antonio, Texas, Technical Contact:, Gordon Baker, General Cable, Highland Heights, Ky., Phone: 859-572-8493; gbaker@generalcable.com, ASTM Staff Contact:, Jennifer Rodgers, Phone: 610-832-9694; jrodgers@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8613
-
Silver-, nickel- and tin-coated flat conductors are currently used in a variety of electronic applications, including computer, and in the military and commercial aerospace industries. Despite this use, flat conductors made of these materials are not covered by established standards. ASTM International Committee B01 on Electrical Conductors is now developing the following three standards to cover…, ASTM Committee B01 Next Meeting: , April 21, 2010 , April Committee Week, St. Louis, Mo., Technical Contact:, Stephen Childers, IWG High Performance Conductors Inc., Inman, S.C., Phone: 864-472-9694; stephen.childers@iwghpc.com, ASTM Staff Contact:, Jennifer Rodgers, Phone: 610-832-9694; jrodgers@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8442/Dec2009
-
ASTM International Committee C13 on Concrete Pipe has approved a new standard that covers flexible joints for concrete box sections using rubber gaskets for leak resistant joints. Subcommittee C13.08 on Joints for Precast Concrete Structures developed ASTM C1677 , Specification for Joints for Concrete Box, Using Rubber Gaskets. “This specification will provide a uniform minimum level of…
-
ASTM International Committee B01 on Electrical Conductors has approved a new standard for tin-coated annealed copper wire. The standard, B965 , Specification for High Performance Tin-Coated Annealed Copper Wire Intended for Electrical and Electronic Application for Solderability, was developed by Subcommittee B01.04 on Conductors of Copper and Copper Alloys . Stephen Childers, process engineer,…
-
The main purpose of any grounding product is to provide a low-resistance path for fault currents to follow to the ground, which will ultimately protect the integrity of the power system and maintain a safe operating environment. ASTM International Committee B01 on Electrical Conductors is developing a proposed new standard to annealed concentric-lay-stranded copper-clad steel conductors. While…