Search
Advanced search
Filter by category
Filter by committee
Search results
-
All interested parties are encouraged to participate in the development of a proposed new ASTM International standard, WK20460 , Specification for High Performance Tinned Coated Annealed Copper Wire Intended for Electrical and Electronic Application for Solderability. The proposed standard is being developed by Subcommittee B01.04 on Conductors of Copper and Copper Alloys, which is part of ASTM…
-
A proposed new ASTM International standard will provide a method for a comparative evaluation of limestone sources available for use in flue gas desulfurization (FGD) applications. The proposed standard, WK20129 , Test Method for Evaluating Limestone for Use in Wet Flue Gas Desulfurization Applications by Reactivity, is being developed by Subcommittee C07.05 on Chemical Tests, part of ASTM…
-
ASTM International Committee E35 on Pesticides and Alternative Control Agents has now published the last in a series of three ASTM International standards that address the activity of hand hygiene agents against microbes that can be transmitted via contaminated hands. Subcommittee E35.15 on Antimicrobial Agents developed the new standard, ASTM E2613 , Test Method for Determining Fungus-…
-
ASTM International Committee E35 on Pesticides and Alternative Control Agents has begun work on the latest in a series of standards on biofilm. The proposed new standard, WK17813 , Test Method for Quantification of a, Pseudomonas aeruginosa, Biofilm Grown with Low Shear and Continuous Flow Using a Drip Flow Biofilm Reactor, is being developed by Subcommittee E35.15 on Antimicrobial Agents. According to Darla M. Goeres, senior research engineer, Center for Biofilm Engineering, and E35 member, biofilm is defined as microorganisms living in a self-organized cooperative community. These communities, which are embedded in slime and can be…, Pseudomonas aeruginosa, Biofilm Grown with High Shear and Continuous Flow Using CDC Biofilm Reactor; and E2196 , Test Method for Quantification of a, Pseudomonas aeruginosa, Biofilm Grown with Shear and Continuous Flow Using a Rotating Disk Reactor) is that biofilm is grown under low fluid shear close to the air/liquid interface and that the drip flow reactor is a plug flow reactor system, resulting in biofilm that is visible to the naked eye and smooth and slimy in appearance. Biofilm generated in a drip flow reactor could represent those found in a wide spectrum of…
-
Biofilm, self-organized communities of bacteria that can have both positive and negative effects in a variety of industries, is the subject of a new ASTM International standard, E 2562 , Test Method for Quantification of Pseudomonas aeruginosa Biofilm Grown with High Shear and Continuous Flow Using CDC Biofilm Reactor. The new standard is under the jurisdiction of Subcommittee E35.15 on…
-
Responding to a new emphasis by regulatory agencies that firms manufacturing drug products demonstrate the efficacy of disinfectants used in controlled environments, ASTM International Committee E35 on Pesticides and Alternative Control Agents has begun to develop a proposed new standard, WK12880 , Guide for Evaluation of Clean Room Disinfectants. WK12880 is under the jurisdiction of Subcommittee…