Search
Advanced search
Filter by category
Filter by committee
Search results
-
ASTM International Committee F02 on Flexible Barrier Packaging is developing a new standard to test the transmission rate of water vapor into packaging materials. Understanding water transmission rate is a key component for the shelf life of many products. “The materials and packages covered by this standard affect nearly every package one sees in grocery stores, pharmacies and hospitals,” says…, ASTM Committee F02 Next Meeting:, Oct. 28-29, 2015, October Committee Week, Tampa, Fla., Media Inquiries:, Nathan Osburn, tel +1.610.832.9603; nosburn@astm.org, Technical Contact:, Joel Fischer, MOCON Laboratory, tel +1.763.493.7219; jfischer@mocon.com, ASTM Staff Contact:, Diane Lake, tel +1.610.832.9661; dlake@astm.org Release #9822 ###
-
Overhead conductors used to transmit electricity typically consist of stranded aluminum wires that surround a stranded steel wire core. However, a more recently developed conductor consists of composite materials of carbon and glass fibers that replace the stranded steel-supporting member. This new type of conductor will be covered in a new ASTM International standard, ASTM B987 , Specification…, ASTM Committee B01 Next Meeting:, April 29, 2015, April Committee Week, Anaheim, Calif., Technical Contact:, Eric Bosze, Ph.D., CTC Global, Irvine, Calif., Phone: +1.949.381.7262; ebosze@ctcglobal.com, ASTM Staff Contact:, Kristy Straiton, Phone: +1.610.832.9640; kstraiton@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: +1.610.832.9603; bschindl@astm.org Release #9694
-
Proper packaging procedures are an important aspect of any industry. Now ASTM International Committee F02 on Flexible Barrier Packaging has developed a standard for a relatively new packaging technology, airborne ultrasound. ASTM F3004 , Test Method for Evaluation of Seal Quality and Integrity Using Airborne Ultrasound, was developed by Subcommittee F02.40 on Package Integrity . “Airborne…, ASTM Committee F02 Next Meeting:, April 7-9, 2014, Lansing, Mich., Technical Contact:, Oliver Stauffer, PTI Inspection Systems, Tuckahoe, N.Y., Phone: 914-337-2005; o.stauffer@ptiusa.com , ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9566
-
ASTM B986 , Test Method for Determination of Tensile Strength by Mass Method for Stranded Conductors Intended for use in Electronic Application, will be used within the electronics and aerospace industries to validate tensile strength specification requirements for electrical conductors. ASTM B986 was developed by Subcommittee B01.02 on Methods of Test and Sampling Procedure , part of ASTM…, ASTM Committee B01 Next Meeting:, Oct. 23, 2013, October Committee Week, Jacksonville, Fla., Technical Contact:, Stephen Childers, IWG High Performance Conductors Inc., Inman, S.C., Phone: 864-472-0438; stephen.childers@iwghpc.com , ASTM Staff Contact:, Kristy Straiton, Phone: 610-832-9640; kstraiton@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9364
-
ASTM International Committee F02 on Flexible Barrier Packaging will hold its next meeting on Sept. 26-27, 2012, at the Hotel Rey Juan Carlos I in Barcelona, Spain. At this meeting, participants will have the opportunity to contribute to the development and revision of a number of standards important to the use and evaluation of flexible barrier packaging. One of the highlights of the meeting will…, Future Trends in Permeation Measurements, , presented by Franz Sturm, Lipke •, U.S. FDA Perspective: The Use of Standards in Premarket Submissions and Auditing the Medical Device Packaging Process, , presented by Pat Weixel, U.S. Food and Drug Administration •, Microbial Barrier Test Methods for Porous Sterile Barrier Materials, , presented by Thierry Wagner, DuPont Medical and Pharmaceutical Protection •, Toward a Package Durability Predictive Model, , presented by Henk Blom, Rollprint Packaging Products •, Package Integrity: Methods of Detection, , presented by Wendy Mach, Nelson Laboratories •, Use of Design Guide F2097 and U.S. FDA Recognition, , Hal Miller, PACE Solutions LLC •, Sterile Medical Device Package Performance Testing and the Nebulous Effect of Vibration in Transit, , presented by Pat Nolan, DDL •, ASTM International: ASTM Mechanics and Overview, , presented by Diane Trinsey, ASTM Committee F02 staff manager All are welcome to attend. Registration and meeting information, including abstracts describing the presentations shown above, can be found at www.astm.org/COMMIT/F02/Barcelona_Meeting_info . Committee F02 develops standards on barrier materials, their properties and package design, development and production. Typical flexible barrier…, ASTM Committee F02 Next Meeting:, Sept. 26-27, 2012, Barcelona, Spain, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9289
-
The construction of an unprecedented number of overhead power lines around the world has increased the demand for accurate data and models for electrical conductors. A proposed new standard, ASTM WK35208, Test Methods for Stress-Strain and Creep Testing for Overhead Electrical Conductors, will answer this global need. ASTM WK35208 is being developed by Subcommittee B01.02 on Methods of Test and…
-
Increasing interest in the various uses of electrical contacts is the leading impetus for the development of a proposed new standard, ASTM WK34423 , Specification for Electrodeposited Coatings of Palladium-Cobalt Alloy for Engineering Use. The proposed standard is being developed by Subcommittee B08.08 on Metallic Coatings , part of ASTM International Committee B08 on Metallic and Inorganic…, ASTM Committee B08 Next Meeting:, May 10, 2012, May Committee Week, Phoenix, Ariz., Technical Contact:, Sheikh H. Rahman, Lean Corp., Southfield, Mich., Phone: 248-447-1526; srahman@lear.com, ASTM Staff Contact:, Diane Trinsey, Phone: 610-832-9661; dtrinsey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9016
-
Halon 1211 is employed in hand-held fire extinguishers on civilian aircraft. A new ASTM International standard will be used to test Halon 1211 to ensure that the product will provide the required level of fire protection and is free of harmful impurities that could affect its safety in use. ASTM D7673 , Specification for Halon 1211, Bromochlorodifluoromethane (CF2BrCl), was developed by…, ASTM Committee D26 Next Meeting:, June 15, 2011, June Committee Week, Anaheim, Calif., Technical Contact:, Mark L. Robin, DuPont Fluoroproducts, Wilmington, Del., Phone: 302-999-5002; mark.l.robin@usa.dupont.com, ASTM Staff Contact:, Christine DeJong, Phone: 610-832-9736; cdejong@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8791
-
A new ASTM subcommittee seeks to acknowledge the ongoing advances being made in the field of nanostructured inorganic coatings. B08.16 on Nanostructured Coatings, part of ASTM International Committee B08 on Metallic and Inorganic Coatings, is currently developing its first proposed standard, ASTM WK29468 , Specification for Galvanic Protection of Steel Using a Nanostructured Coating of 95 % Zinc…
-
Code words have historically been used in the electrical conductor industry as a simple method of identifying the construction details of an overhead conductor product. A proposed new ASTM standard will list code word names and provide a means to register and publish new code words. ASTM WK28737 , Specification for Electrical Overhead Conductor Code Word Names, is being developed by Subcommittee…, ASTM Committee B01 Next Meeting:, Oct. 13, October Committee Week, San Antonio, Texas, Technical Contact:, Gordon Baker, General Cable, Highland Heights, Ky., Phone: 859-572-8493; gbaker@generalcable.com, ASTM Staff Contact:, Jennifer Rodgers, Phone: 610-832-9694; jrodgers@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8613