Search
Advanced search
Filter by category
Filter by committee
Search results
-
Since 2009, the National Fire Protection Association has required arc rated gloves in its NFPA70E, Standard for Electrical Safety in the Workplace. A new ASTM standard will now provide arc rating thermal protective values for gloves, which will allow more gloves to be used inside an arc flash zone when there is no shock hazard. The new standard, ASTM F2675/F2675M , Test Method for Determining Arc…, ASTM Committee F18 Next Meeting:, Oct. 20-23, 2013, Charleston, S.C., Technical Contact:, Hugh Hoagland, ArcWear, Louisville, Ky., Phone: 502-832-9737; hugh@arcwear.com , ASTM Staff Contact:, Kevin Shanahan, Phone: 610-832-9737, kshanahan@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9469
-
The headspace in domestic wastewater collection and treatment systems is a severe environment that can impact even high performance protective coatings. A proposed new ASTM International standard covers an apparatus and set of procedures that are used to create and maintain a simulated sewer headspace environment to be used to test potential coatings. ASTM WK33537 , Practice for Operating the…, ASTM Committee G01 Next Meeting:, Nov. 12-14, 2013, November Committee Week, Jacksonville, Fla., Technical Contact:, Vaughn O’Dea, Tnemec Co. Inc., Kansas City, Mo., Phone: 816-519-2267; odea@tnemec.com , ASTM Staff Contact:, Jennifer Rodgers, Phone: 610-832-9694; jrodgers@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9438
-
ASTM B986 , Test Method for Determination of Tensile Strength by Mass Method for Stranded Conductors Intended for use in Electronic Application, will be used within the electronics and aerospace industries to validate tensile strength specification requirements for electrical conductors. ASTM B986 was developed by Subcommittee B01.02 on Methods of Test and Sampling Procedure , part of ASTM…, ASTM Committee B01 Next Meeting:, Oct. 23, 2013, October Committee Week, Jacksonville, Fla., Technical Contact:, Stephen Childers, IWG High Performance Conductors Inc., Inman, S.C., Phone: 864-472-0438; stephen.childers@iwghpc.com , ASTM Staff Contact:, Kristy Straiton, Phone: 610-832-9640; kstraiton@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9364
-
ASTM International Committee G01 on Corrosion of Metals has an ongoing commitment to help the oil field industries adopt and use state-of-the-art techniques to control corrosion. As part of this commitment, Subcommittee G01.05 on Laboratory Corrosion Tests has approved ASTM G205 , Guide for Determining Corrosivity of Crude Oils. ASTM G205 is the result of collaboration among members of Task Group…, ASTM Committee G01 Next Meeting:, Nov. 13-15, November Committee Week, Atlanta, Ga., Technical Contact:, Sankara Papavinasam, Ph.D., CanmetMATERIALS, Hamilton, Ontario, Canada, Phone: 613-947-4603; spapavin@nrcan.gc.ca, ASTM Staff Contact:, Jennifer Rodgers, Phone: 610-832-9694; jrodgers@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9297
-
A proposed new ASTM International standard will detail a multilevel approach for performing above- and below-ground inspection of transmission poles and lattice towers in the field. ASTM WK35986, Test Method for Field Inspection of Transmission Poles and Lattice Towers, will be used by utilities to provide tools for maintenance departments that inspect and repair transmission structures. ASTM…
-
The construction of an unprecedented number of overhead power lines around the world has increased the demand for accurate data and models for electrical conductors. A proposed new standard, ASTM WK35208, Test Methods for Stress-Strain and Creep Testing for Overhead Electrical Conductors, will answer this global need. ASTM WK35208 is being developed by Subcommittee B01.02 on Methods of Test and…
-
A proposed new standard being developed by ASTM International Committee F18 on Electrical Protective Equipment for Workers will provide guidance to assist in the required testing of live-line tools. ASTM WK33590 , Guide for In-Service Inspection, Maintenance and Electrical Testing of Insulating Tools (Fiberglass-Reinforced Plastic (FPR) and Wooden Live-Line Tools), is under the jurisdiction of…
-
Once approved, a proposed new ASTM International standard will aid in the evaluation of high performance protective coatings for sewerage systems. The proposed standard will provide a test specific to these coatings. Subcommittee G01.05 on Laboratory Corrosion Tests is developing ASTM WK33537 , Practice for Operating the Severe Wastewater Analysis Testing Apparatus. G01.05 is under the…, ASTM Committee G01 Next Meeting:, Nov. 16-17, 2011, November Committee Week, Tampa, Fla., Technical Contact:, Vaughn O’Dea, Tnemec Co. Inc., Kansas City, MO, Phone: 816-519-2267; odea@tnemec.com, ASTM Staff Contact:, Jennifer Rodgers, Phone: 610-832-9694; jrodgers@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8977
-
A new ASTM International standard will provide a method of testing corrosion-resistant fasteners and their performance in contact with treated wood. ASTM G198 , Test Method for Determining the Relative Corrosion Performance of Driven Fasteners in Contact with Treated Wood, was developed by Subcommittee G01.14 on Corrosion of Metals in Construction Materials , part of ASTM International Committee…
-
Code words have historically been used in the electrical conductor industry as a simple method of identifying the construction details of an overhead conductor product. A proposed new ASTM standard will list code word names and provide a means to register and publish new code words. ASTM WK28737 , Specification for Electrical Overhead Conductor Code Word Names, is being developed by Subcommittee…, ASTM Committee B01 Next Meeting:, Oct. 13, October Committee Week, San Antonio, Texas, Technical Contact:, Gordon Baker, General Cable, Highland Heights, Ky., Phone: 859-572-8493; gbaker@generalcable.com, ASTM Staff Contact:, Jennifer Rodgers, Phone: 610-832-9694; jrodgers@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8613