Search
Advanced search
Filter by category
Filter by committee
Search results
-
ASTM International Committee E55 on Manufacture of Pharmaceutical Products is currently developing a proposed standard that will document a set of process steps that can reproducibly inactivate or remove any potential retrovirus in new biological products, particularly antibodies and antibody-like compounds. The proposed standard, ASTM WK39883 , Practice for Process of Inactivation of Enveloped…, ASTM Committee E55 Next Meeting:, April 9-11, 2013, Genzyme-A Sanofi Company, Haverhill, Suffolk, United Kingdom, Technical Contact:, John Schreffler, Ph.D., Morphotek Inc., Exton, Pa., Phone: 610-423-6557; jschreffler@morphotek.com, ASTM Staff Contact:, Christine DeJong, Phone: 610-832-9736; cdejong@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9327
-
A newly revised ASTM terminology standard reflects the latest technological advances in particle size analysis (standard test sieves) and particle separation (screening media). ASTM E1638 , Terminology Relating to Sieves, Sieving Methods and Screening Media, was developed by Subcommittee E29.01 on Sieves, Sieving Methods and Screening Media , part of ASTM International Committee E29 on Particle…, ASTM Committee E29 Next Meeting:, May 1-2, 2013, in conjunction with B09 May meeting, Ft. Lauderdale Beach, Fla., Technical Contact:, Kenneth H. Beyer, American Wire Cloth Institute, Elizabeth, N.J., Phone: 908-688-4600; ken@uniquewire.com, ASTM Staff Contact:, Katerina Koperna, Phone: 610-832-9728; kkoperna@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9290
-
A proposed new ASTM International standard will provide an important process step to be used in the manufacture of protein-based drugs, such as antibodies and fusion proteins, made to inactivate retroviruses. The proposed standard, ASTM WK36552 , Practice for Inactivation of Retrovirus by pH, is being developed by Subcommittee E55.04 on General Biopharmaceutical Standards , part of ASTM…
-
Sealant manufacturers will use a new ASTM International standard to evaluate new products and changes to these products due to exposure to weather. The new standard, ASTM C1735 , Test Method for Measuring the Time Dependent Modulus of Sealants Using Stress Relaxation, is under the jurisdiction of Subcommittee C24.20 on General Test Methods , part of ASTM International Committee C24 on Building…, ASTM Committee C24 Next Meeting:, Jan. 8-10, 2012, Ft. Lauderdale, Fla., Technical Contact:, Christopher C. White, Ph.D., National Institute of Standards and Technology, Gaithersburg, Md., Phone: 301-975-6016; christopher.white@nist.gov, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9005
-
A new ASTM International test method will provide an effective screening method to identify magnets that are subject to excessive corrosion in high humidity environments. ASTM A1071/A1071M , Test Method for Evaluating Hygrothermal Corrosion Resistance of Permanent Magnet Alloys, was developed by Subcommittee A06.01 on Test Methods , part of ASTM International Committee A06 on Magnetic Properties…
-
ASTM International Committee A06 on Magnetic Properties welcomes the participation of all stakeholders with an interest in the development of international standards for magnetic materials and magnetic properties. The committee will hold its biannual meeting this fall. ASTM Committee A06, which was formed in 1903, oversees approximately 50 standards dealing with magnetic materials and magnetic…, ASTM Staff Contact:, Kelly Paul, Phone: 610-832-9745; kpaul@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8975
-
A new ASTM International standard covers a special grade of industrial woven wire cloth called filter cloth for general filtration, including the separation of solids from fluids. ASTM E2814 , Guide for Industrial Woven Wire Filter Cloth, was developed by Subcommittee E29.01 on Sieves, Sieving Methods and Screening Media , part of ASTM International Committee E29 on Particle and Spray…, ASTM Committee E29 Next Meeting:, Oct. 31-Nov. 1, 2011, October Committee Week, Tampa, Fla., Technical Contact:, Ken Beyer, Unique Wire Weaving Co., Hillside, N.J., Phone: 908-688-4600; ken@uniquewire.com, ASTM Staff Contact:, Christine Sierk, Phone: 610-832-9728; csierk@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8934
-
ASTM International Committee E29 on Particle and Spray Characterization has recently approved an extensive revision of ASTM standard E11 , Specification for Wire Cloth and Sieves for Testing Purposes. The revision will lead to better control of the quality of sieve cloths and test sieves. ASTM E11 is under the jurisdiction of Subcommittee E29.01 on Sieves, Sieving Methods and Screening Media.…
-
The use of rolling devices can provide a means to evaluate the adhesion of weather seals, for quality control in new installations, general evaluation of existing installations, and the investigation of water and air leakage through building enclosures. In order to better facilitate the use of rolling devices, ASTM International Committee C24 on Building Seals and Sealants is developing a…
-
While the continuous quality verification concept is still quite new, it has the potential to become an important approach to assuring product quality in the pharmaceutical industry. With this in mind, ASTM International Committee E55 on Manufacture of Pharmaceutical Products has approved a new standard, E2537 , Guide for Application of Continuous Quality Verification to Pharmaceutical and…