It happens all too often: a driver suddenly loses control of a car, sending it into a storefront or other pedestrian area. Property damage and serious injuries, sometimes fatal, can result from these accidents. In an effort to minimize the damage caused by such crashes, ASTM International Committee F12 on Security Systems and Equipment is developing a proposed new standard, ASTM WK13074 , Test…, ASTM Committee F12 Next Meeting:, Oct. 22-24, 2012, October Committee Week, Atlanta, Ga., Technical Contacts:, Rob Reiter, Storefront Safety Consultant, Phone: 909-964-2906; r ob.reiter.pp@gmail.com ; Dean Alberson, Texas Transportation Institute, Texas A&M University, Phone: 979-458-3874; d-alberson@tamu.edu, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindler@astm.org R elease #9263
-
A new ASTM International test method will provide an effective screening method to identify magnets that are subject to excessive corrosion in high humidity environments. ASTM A1071/A1071M , Test Method for Evaluating Hygrothermal Corrosion Resistance of Permanent Magnet Alloys, was developed by Subcommittee A06.01 on Test Methods , part of ASTM International Committee A06 on Magnetic Properties…
-
ASTM International Committee A06 on Magnetic Properties welcomes the participation of all stakeholders with an interest in the development of international standards for magnetic materials and magnetic properties. The committee will hold its biannual meeting this fall. ASTM Committee A06, which was formed in 1903, oversees approximately 50 standards dealing with magnetic materials and magnetic…, ASTM Staff Contact:, Kelly Paul, Phone: 610-832-9745; kpaul@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8975
-
Discussions concerning how easily test results for dimension stone test specimens can be influenced by improper or nonuniform preparation methods have led to the ongoing development of a proposed new ASTM International standard. The new standard, ASTM WK31179 , Practice for Selection and Preparation of Dimension Stone Test Specimens, is being developed by Subcommittee C18.08 on Selection of…
-
ASTM International Committee F12 on Security Systems and Equipment invites all interested parties to participate in the current revision of ASTM F967 , Practice for Security Engineering Symbols. The standard is under the jurisdiction of Subcommittee F12.10 on Systems, Products and Services. According to Ed Conrath, senior principal, Protection Engineering Consultants, and F12 committee chairman,…
-
“Bumping” is a process that can allow virtually anyone to covertly operate a pin tumbler lock. A long-held locksmith secret, bumping has become more well known as videos describing the process of making and using a bump key have surfaced on the Internet. Potential intruders can use the bumping process to break into homes and other buildings while leaving the impression that something must have…
-
Petrography is routinely performed on dimension stone for many construction projects in which new stone is being used, and it is often required in technical specifications. In order to facilitate this process, ASTM International Committee C18 on Dimension Stone has developed a new standard, ASTM C1721 , Guide for Petrographic Examination of Dimension Stone. The new standard is under the…, ASTM Committee C18 Next Meeting:, April 21-22, April Committee Week, St. Louis, Mo., Technical Contact:, Michael Scheffler, Wiss, Janney, Elstner Associates Inc., Northbrook, Ill., Phone: 847-272-7400; mscheffler@wje.com, ASTM Staff Contact:, Jeff Adkins, Phone: 610-832-9738; jadkins@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8432/Dec2009
-
ASTM International Committee F12 on Security Systems and Equipment has approved a new standard, F 2656 , Test Method for Vehicle Crash Testing of Perimeter Barriers. The new test method, developed by Subcommittee F12.10 on Systems, Products and Services, provides a range of vehicle impact conditions, designations and penetration performance levels for the testing of perimeter barriers that are…
-
ASTM International Committee A06 on Magnetic Properties has approved the first in a series of proposed standards on permanent magnet materials. The new standard, A 1054 , Specification for Sintered Ceramic Ferrite Permanent Magnets, as well as the other proposed standards, are under the jurisdiction of Subcommittee A06.02 on Material Specifications. While ASTM has long had standards covering…
-
It has become a common scene: a driver in a parking lot suddenly loses control of a car, sending it into a storefront or other pedestrian area. In an effort to minimize the injury and damage caused by such crashes, ASTM International Committee F12 on Security Systems and Equipment is developing a proposed new standard, WK13074 , Test Method for Crash Testing of Low Speed Pedestrian Barriers. The…