Many types of surgical implants and other medical devices are made of polymeric materials. A new ASTM standard covers the raw material properties for a high strength polymer used for surgical implants. ASTM F2820 , Specification for Polyetherketoneketone (PEKK) Polymers for Surgical Implant Applications, has been developed by ASTM International Subcommittee F04.11 on Polymeric Materials , part of…, ASTM Committee F04 Next Meeting:, May 21-24, 2013, May Committee Week, Indianapolis, Ind., Technical Contact:, Jon P. Moseley, Ph.D., Wright Medical Technology Inc., Arlington, Tenn., Phone: 901-867-4414; jon.moseley@wmt.com, ASTM Staff Contact:, Pat Picariello, Phone: 610-832-9720, ppicariello@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9276
-
A new ASTM International standard provides a much-needed methodology for determining the shelf life of various attributes of endovascular devices. The new standard, ASTM F2914 , Guide for Identification of Shelf-Life Test Attributes for Endovascular Devices, was developed by Subcommittee F04.30 on Cardiovascular Standards , part of ASTM International Committee F04 on Medical and Surgical…, ASTM Committee F04 Next Meeting:, Nov. 13-16, 2012, November Committee Week, Atlanta, Ga., Technical Contact:, Benjamin Gundale, Boston Scientific, Maple Grove, Minn., Phone: 763-494-2771; gundaleb@bsci.com, ASTM Staff Contact:, Pat Picariello, Phone: 610-832-9720; ppicarie@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9264
-
New functionalities in a particular group of orthopedic spinal devices will be addressed in a proposed new ASTM standard. ASTM WK34549 , Test Methods for Intervertebral Body Fusion Devices with Integrated Fixation Components, is being developed by Subcommittee F04.25 on Spinal Devices , part of ASTM International Committee F04 on Medical and Surgical Materials and Devices . According to Andrew…
-
One of the most important characteristics of a curved surgical needle is how easily it can pass through tissue. This characteristic, known as penetration force, is important for several reasons, which include minimizing scarring and dealing with highly communicable diseases such as hepatitis. ASTM International Committee F04 on Medical and Surgical Materials and Devices is currently developing a…
-
There are currently several uses of alloy UNS R56320 in surgical applications and implants, but the only ASTM surgical standard for the alloys covers tubing [ ASTM F2146 , Specification for Wrought Titanium-3Aluminum-2.5Vanadium Alloy Seamless Tubing for Surgical Implant Applications (UNS R56320)]. A proposed new ASTM standard will reflect the more widespread use of UNS R56320. ASTM WK34079 ,…
-
A new ASTM International test method will provide an effective screening method to identify magnets that are subject to excessive corrosion in high humidity environments. ASTM A1071/A1071M , Test Method for Evaluating Hygrothermal Corrosion Resistance of Permanent Magnet Alloys, was developed by Subcommittee A06.01 on Test Methods , part of ASTM International Committee A06 on Magnetic Properties…
-
ASTM International Committee A06 on Magnetic Properties welcomes the participation of all stakeholders with an interest in the development of international standards for magnetic materials and magnetic properties. The committee will hold its biannual meeting this fall. ASTM Committee A06, which was formed in 1903, oversees approximately 50 standards dealing with magnetic materials and magnetic…, ASTM Staff Contact:, Kelly Paul, Phone: 610-832-9745; kpaul@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8975
-
Epifluorescence microscopes are used to generate fluorescence intensity images in several biology applications. A proposed new ASTM International standard will provide guidance on how to set up an experiment that uses an epifluorescence microscope to ensure that the imaging measurements are quantitative. The proposed standard will also provide guidance on how to use benchmarks to allow…, ASTM Committee F04 Next Meeting:, Nov. 15-18, 2011, November Committee Week, Tampa, Fla., Technical Contact:, John Elliot, National Institute of Standards and Technology, Gaithersburg, Md., Phone: 310-975-8551; jelliott@nist.gov, ASTM Staff Contact:, Pat Picariello, Phone: 610-832-9720; ppicarie@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8945
-
A new ASTM International standard, adopted from an American Concrete Institute test method, will be used to help ensure the safety of construction projects. ASTM C1741 , Test Method for Bleed Stability of Cementitious Post-Tensioning Tendon Grout, is under the jurisdiction of Subcommittee C09.41 on Hydraulic Cement Grouts , part of ASTM International Committee C09 on Concrete and Concrete…
-
Piston ring/liner interface can contribute as much as half the total friction loss in internal combustion engines, with the resulting wear leading to reduced energy efficiency and raised emissions. A new ASTM International standard provides a method to more accurately measure small amounts of wear on curved piston ring segments and their counterfaces after lubricated bench-scale testing. “Coupled…