Search
Advanced search
Filter by category
Filter by committee
Search results
-
High-strength turf reinforcement mats made from vegetative or synthetic materials (or a combination of both) are used to prevent soil erosion in drainage areas and on steep slopes. A proposed new ASTM International standard, ASTM WK38408 , Specification for Turf Reinforcement Mats, will be focused on mats made only with geosynthetics (no organic materials). ASTM WK38408 is being developed by…, ASTM Committee D35 Next Meeting:, Jan. 30-Feb. 1, 2013, January Committee Week, Jacksonville, Fla., Technical Contact:, Robert Mackey, P.E., BCEE, S2L Inc., Maitland, Fla., Phone: 407-475-9163; bmackey@s2li.com, ASTM Staff Contact:, Katerina Koperna, Phone: 610-832-9728; kkoperna@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9312
-
In a quest for lighter, more crash-resistant and fuel-efficient vehicles, the automobile and steel industries are developing steel sheets that have higher alloy content, and thus more complex hardening mechanisms, than sheets currently being used. The sheets, known generally as advanced high-strength steels, are covered by a new ASTM International standard, ASTM A1079 , Specification for Steel…, ASTM Committee A05 Next Meeting:, Nov. 11-13, November Committee Week, Atlanta, Ga., Technical Contact:, Gary Dallin, GalvInfo Center, International Zinc Association, Burlington, Ontario, Canada, Phone: 905-315-7443; gdallin@cogeco.ca, ASTM Staff Contact:, Kristy Straiton, Phone: 610-832-9640; kstraiton@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9304
-
Geomembranes are used as hydraulic and gas barriers for pond and canal liners, landfill liners, caps, floating covers and other applications. Factory fabricated geomembranes that require less on-site installation work are becoming more prominent, but contractors, owners and site engineers are not always familiar with these. A proposed new ASTM International standard will provide guidance for…, ASTM Committee D35 Next Meeting:, Jan. 30-Feb 1, 2013, January Committee Week, Jacksonville, Fla., Technical Contact:, Gary M. Kolbasuk, Raven Industries EFD, Sioux Falls, SD, Phone: 605-331-0324; gary.kolbasuk.revenind.com, ASTM Staff Contact:, Katerina Koperna Phone: 610-832-9728; kkoperna@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9269
-
A new ASTM International standard that will help ensure the accurate use of micrometers in the measurement of a type of steel sheet has been developed and approved by ASTM International Committee A05 on Metallic-Coated Iron and Steel Products . ASTM A1073/A1073M , Practice for Using Hand Micrometers to Measure the Thickness of Nonmetallic and Metallic-Coated Steel Sheet, is under the…, ASTM Committee ASTM Committee A05 Next Meeting:, Nov. 11-13, 2012, November Committee Week, Atlanta, Ga., Technical Contact:, Herbert W. Koch, Harris Steel Co., Chicago, Ill., Phone: 708-656-5500; hkoch@harrissteelco.com, ASTM Staff Contact:, Kristy Straiton, Phone: 610-832-9640; kstraiton@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9254
-
A new ASTM International test method that provides standardization for a long-used test will aid in the use and evolution of geotextile bag technology. The new standard, ASTM D7701 , Test Method for Determining the Flow Rate of Water and Suspended Soils from a Geotextile Bag, was developed by Subcommittee D35.03 on Permeability and Filtration , part of ASTM International Committee D35 on…
-
A new ASTM International practice standardizes a geoelectric method used to detect potential leaks in exposed electrically isolating membranes in the field in containment applications. The new standard, ASTM D7703 , Practice for Electrical Leak Location on Exposed Geomembranes Using the Water Lance System, is under the jurisdiction of Subcommittee D35.10 on Geomembranes , part of ASTM…, ASTM Committee D35 Next Meeting:, Feb. 1-3, 2012, January Committee Week, Atlanta, Ga., Technical Contact:, Tim Bauters, Ph.D., Golder Associates Inc., Sunnyvale, Calif., Phone: 408-220-9223; tim_bauters@golder.com, ASTM Staff Contact:, Christine Sierk, Phone: 610-832-9728; csierk@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9007
-
Laboratories that have the ability to analyze titanium and titanium alloys by spark-atomic emission spectrometry or glow discharge-AES are currently being sought to participate in an interlaboratory study for a proposed new standard. ASTM WK25738 , Test Method for Analysis of Titanium and Titanium Alloys by Spark-Atomic Emission/Glow Discharge-Atomic Emission Spectrometry, is currently being…, ASTM Committee E01 Next Meeting:, May 15-18, 2011, May Committee Week, Anaheim, Calif., Technical Contact:, Kevin VonScio, Perryman Co., Houston, Pa., Phone: 724-746-9390; kvonscio@perrymanco.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8855
-
Owners and specifiers of steel building projects will be the primary users of a new ASTM International standard, ASTM A1068 , Practice for Life-Cycle Cost Analysis of Corrosion Protection Systems on Iron and Steel Products. The new standard was developed by Subcommittee A05.13 on Structural Shapes and Hardware Specifications, part of ASTM International Committee A05 on Metallic-Coated Iron and…
-
Subcommittee A05.13 on Structural Shapes and Hardware Specifications is currently working on proposed new standards that would be used by engineers and architects who design with steel fabrications. These proposed standards will be used to evaluate the costs of steel construction over the lifetime of a project and to compare different corrosion protection systems on their impact to this lifetime…
-
Trona, or sodium sesquicarbonate, is a fine mineral powder that has proven to be effective at removing acid gases from air emissions. While trona can be a useful component of air pollution control systems, it can be difficult to handle, particularly when moisture is present. A proposed new ASTM standard will present a repeatable, precise and accurate test method for analyzing moisture levels in…, ASTM Committee E01 Next Meeting:, Nov. 14-17, November Committee Week, San Antonio, Texas, Technical Contact: J, ames D. Phillip, Solvay Chemicals Inc, Green River, Wyo., Phone: 307-872-6519; jim.phillip@solvay.com, ASTM Staff Contact:, Thomas O'Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #8608