Search
Advanced search
Filter by category
Filter by committee
Search results
-
A new ASTM International standard that will help ensure the accurate use of micrometers in the measurement of a type of steel sheet has been developed and approved by ASTM International Committee A05 on Metallic-Coated Iron and Steel Products . ASTM A1073/A1073M , Practice for Using Hand Micrometers to Measure the Thickness of Nonmetallic and Metallic-Coated Steel Sheet, is under the…, ASTM Committee ASTM Committee A05 Next Meeting:, Nov. 11-13, 2012, November Committee Week, Atlanta, Ga., Technical Contact:, Herbert W. Koch, Harris Steel Co., Chicago, Ill., Phone: 708-656-5500; hkoch@harrissteelco.com, ASTM Staff Contact:, Kristy Straiton, Phone: 610-832-9640; kstraiton@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9254
-
Single-sized cured-in-place liners for manholes were developed to improve efficiency by reducing time and effort required to rehabilitate a manhole without the need for excavation. A proposed new ASTM standard on such liners is currently being developed by ASTM International Committee F17 on Plastic Piping Systems . ASTM WK36573 , Practice for the Installation of a Single-Sized Cured-in-Place…
-
ASTM International Committee F17 on Plastic Piping Systems is currently working on a series of proposed new standards for polyethylene pipe fittings. The proposed standards will enable pipeline and piping project development using uniform fittings dimensions from every fabricator. “Today the consulting and engineering community uses 3-D modeling to develop and check project piping,” says Harvey…, ASTM Committee F17 Next Meeting:, April 16-18, 2012, April Committee Week, Phoenix, Ariz., Technical Contact:, Harvey Svetlik, Independent Pipe Products, Dallas, Texas, Phone: 800-499-6927; hsvetlik@indpipe.net, ASTM Staff Contact:, Robert Morgan, Phone: 610-832-9732; rmorgan@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9109
-
Sealant manufacturers will use a new ASTM International standard to evaluate new products and changes to these products due to exposure to weather. The new standard, ASTM C1735 , Test Method for Measuring the Time Dependent Modulus of Sealants Using Stress Relaxation, is under the jurisdiction of Subcommittee C24.20 on General Test Methods , part of ASTM International Committee C24 on Building…, ASTM Committee C24 Next Meeting:, Jan. 8-10, 2012, Ft. Lauderdale, Fla., Technical Contact:, Christopher C. White, Ph.D., National Institute of Standards and Technology, Gaithersburg, Md., Phone: 301-975-6016; christopher.white@nist.gov, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9005
-
Although PVC gasketed sewer basins are currently being produced and supplied to the storm drainage market, there are not currently minimum requirements users can refer to for a purchase. A proposed new ASTM International standard will provide these requirements. ASTM WK32336 , Specification for Poly(Vinyl Chloride) (PVC) Gasketed Sanitary and Storm Drainage Sewer Basins and Fittings, is being…
-
Owners and specifiers of steel building projects will be the primary users of a new ASTM International standard, ASTM A1068 , Practice for Life-Cycle Cost Analysis of Corrosion Protection Systems on Iron and Steel Products. The new standard was developed by Subcommittee A05.13 on Structural Shapes and Hardware Specifications, part of ASTM International Committee A05 on Metallic-Coated Iron and…
-
Ensuring effective knowledge of underground assets and systems is essential for gas utility companies that are implementing plans to address regulatory initiatives and reporting requirements. A new ASTM International specification provides a comprehensive plan for tracking and tracing these assets. The new standard, ASTM F2897 , Specification for Tracking and Traceability Encoding System of…
-
Innovations in the equations and other analytical tools that engineers have used when designing close-fit liners for plastic pipe have led to a need for a new standard for design calculations. This need will be met by a proposed new ASTM International standard, ASTM WK29237, Practice for Design Calculations of Close-Fit Liners. The proposed new standard is being developed by Subcommittee F17.67…
-
Subcommittee A05.13 on Structural Shapes and Hardware Specifications is currently working on proposed new standards that would be used by engineers and architects who design with steel fabrications. These proposed standards will be used to evaluate the costs of steel construction over the lifetime of a project and to compare different corrosion protection systems on their impact to this lifetime…
-
ASTM International Committee F17 on Plastic Piping Systems has just completed the development of two new standards for polypropylene sanitary sewer pipe. These new standards are the first to address both dual wall and triple wall profile designs. “Polypropylene has unique material characteristics, which make it ideal for sanitary sewer pipe applications,” says John Kurdziel, director, technical…