Search
Advanced search
Filter by category
Filter by committee
Search results
-
A new ASTM International standard will provide safety and risk management professionals with an aid in measuring the slip resistance of footwear in a wide variety of flooring situations. ASTM F2913 , Test Method for Measuring the Coefficient of Friction for Evaluation of Slip Performance of Footwear and Test Surfaces/Flooring Using a Whole Shoe Tester, is under the jurisdiction of Subcommittee…
-
A watertight septic system ensures its integrity, and demonstrating that integrity is important because such systems have over time become more complex, expensive and critical to both system owners and to the environment. A new ASTM International standard fills a need for an in-field installation test for septic systems. The new standard, ASTM C1719 , Test Method for Installed Precast Concrete…, ASTM Committee C27 Next Meeting:, Dec. 6-7, 2011, December Committee Week, Tampa, Fla., Technical Contact:, Michael R. Miller, Press-Seal Gasket Corp., Fort Wayne, Ind., Phone: 260-918-1626; mmiler@press-seal.com, ASTM Staff Contact:, Joseph Hugo, Phone: 610-832-9740; jhugo@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9008
-
Sealant manufacturers will use a new ASTM International standard to evaluate new products and changes to these products due to exposure to weather. The new standard, ASTM C1735 , Test Method for Measuring the Time Dependent Modulus of Sealants Using Stress Relaxation, is under the jurisdiction of Subcommittee C24.20 on General Test Methods , part of ASTM International Committee C24 on Building…, ASTM Committee C24 Next Meeting:, Jan. 8-10, 2012, Ft. Lauderdale, Fla., Technical Contact:, Christopher C. White, Ph.D., National Institute of Standards and Technology, Gaithersburg, Md., Phone: 301-975-6016; christopher.white@nist.gov, ASTM Staff Contact:, Stephen Mawn, Phone: 610-832-9726; smawn@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9005
-
Tribometers are used to assess the potential of humans to slip while walking on various surfaces. A new ASTM International test method will be used to provide a reference standard against which to validate and calibrate the performance of tribometers. ASTM F2508 , Practice for Validation and Calibration of Walkway Tribometers Using Reference Surfaces, has been developed by Subcommittee F13.10 on…
-
ASTM International Committee F13 on Pedestrian/Walkway Safety and Footwear is currently working on a proposed new standard for footwear designed for workers who do not necessarily need safety toe shoes but could use other protection such as puncture resistance, electrical shock protection and electrical grounding. The proposed new standard, ASTM WK27855 , Specification for Performance…
-
The use of rolling devices can provide a means to evaluate the adhesion of weather seals, for quality control in new installations, general evaluation of existing installations, and the investigation of water and air leakage through building enclosures. In order to better facilitate the use of rolling devices, ASTM International Committee C24 on Building Seals and Sealants is developing a…
-
Responding to an increasing level of interest from engineers, regulators and communities, ASTM International Committee C27 on Precast Concrete Products has formed new Subcommittee C27.70 on Precast Concrete Products for Stormwater Management. “New environmental regulations, as well as vastly improved methods of meeting these, have created many new products and practices for stormwater management…
-
Although alkali resistant glass fibers have been commercially available for more than 30 years, there has not been an official standard that clearly defines what is required to make glass fibers resistant to alkali attack without the need for protective coatings. ASTM International Committee C27 on Precast Concrete Products has recently developed such a standard, C 1666/C 1666M , Specification…
-
ASTM International Committee C24 on Building Seals and Sealants invites interested parties to participate in the development of a proposed new standard that will use photographs to illustrate various types of sealant failures. WK11731 , Guide for Diagnosing Sealant Failure by Comparison to Reference Photographs, is under the jurisdiction of Subcommittee C24.10 on Specifications, Guides and…
-
Ineffective removal of grease from restaurants poses a variety of serious environmental problems. Large quantities of grease in public sanitary sewer systems can cause stoppages of piping networks and create costly and time-consuming problems at treatment plants. Sewer backups resulting from grease can also create health hazards when raw sewage backs up into homes or businesses. While grease…