Search
Advanced search
Filter by category
Filter by committee
Search results
-
Infrastructure projects rely on reinforced concrete as a principal construction material. Each year, more than $1.3 trillion is spent constructing new infrastructure or repairing/replacing old infrastructure for energy, water, communications and transportation systems. A proposed ASTM International standard will cover the protection of zinc-coated steel bars used for concrete reinforcement in…, ASTM Committee A01 Next Meeting:, Nov. 10-13, 2014, November Committee Week, New Orleans, La., Technical Contact:, Gary W. Dallin, GalvInfo Center, Burlington, Ontario, Canada, Phone: 905-315-7443; gdallin@cogeco.ca, ASTM Staff Contact:, Kevin Shanahan, Phone: 610-832-9737; kshanahan@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9658
-
A proposed new ASTM International standard will aid in understanding thermal transport properties, an important component in optimizing the energy efficiency of building materials and improving thermal design in electronics, fuel cells and batteries. The test described in ASTM WK46204, Test Method for Determination of Thermal Conductivity and Thermal Diffusivity of Solids and Fluids Using the…, ASTM Committee E37 Next Meeting:, Aug. 29, University of Delaware Center for Composite Materials, Newark, Del., Technical Contact:, Mattias Gustavsson, Ph.D., Hot Disk AB, Gothenburg, Sweden, Phone: +46-31-411-410; mattias.gustavsson@hotdiskinstruments.com , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9629
-
Adopted in 2005, Chapter 7A of the California Building Code describes provisions for attic vents for new construction in wildfire-prone areas. While the California code notes that attic vents should resist the intrusion of embers and flames, there had not been a standard to evaluate such intrusion. A new standard, ASTM E2886/E2886M , Test Method for Evaluating the Ability of Exterior Vents to…, ASTM Committee E05 Next Meeting:, Dec. 8-11, 2014, December Committee, New Orleans, La., Technical Contact:, Stephen Quarles, Insurance Institute for Business and Home Safety, Richburg, S.C., Phone: 803-789-4209; squarles@ibhs.org , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9617
-
The steel bases of power transmission poles are a critical but often unnoticed component of electrical infrastructure. Proper performance of such bases helps ensure uninterrupted power to homes, businesses, schools and any other venue using electrical power. A new ASTM International standard, ASTM A1090/A1090M , Specification for Forged Rings and Hollows Produced from Steels with Atmospheric…, ASTM Committee A01 Next Meeting:, Nov. 10-13, 2014, November Committee Week, New Orleans, La., Technical Contact:, Patrick Nowak, Scot Forge, Clinton, Wis., Phone: 608-676-2288; pnowak@scotforge.com , ASTM Staff Contact:, Kevin Shanahan, Phone: 610-832-9737; kshanahan@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9652
-
A proposed new ASTM International standard is being developed for mounting plastic pipe and tube in the Steiner tunnel furnace. The draft procedure will help determine the fire-related properties of the pipe and tube in accordance with ASTM E84, Test Method for Surface Burning Characteristics of Building Materials. ASTM WK44535 , Practice for Mounting of Plastic Pipe, Plastic Tubing, Plastic Pipe…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee, Toronto, Ontario, Canada, Technical Contact:, Joe Zicherman, Fire Cause Analysis, Berkeley, Calif., Phone: 510-649-1300; zicherman46@gmail.com, ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9635
-
A proposed new ASTM International standard will provide an effective low temperature performance graded asphalt binder system using dynamic shear rheometry. ASTM WK45135 , Test Method for Determining the Low Temperature Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR), is being developed by Subcommittee D04.44 on Rheological Tests , part of ASTM International…, ASTM Committee D04 Next Meeting:, June 24-26, 2014, June Committee Week, Toronto, Ontario, Canada, Technical Contact:, Stacy Glidden, Mathy Construction Co., Onalaska, Wis., Phone: 608-779-6352; stacy.glidden@mteservices.com ; Michael J. Farrar, Western Research Institute, Laramie, Wyo., Phone: 307-721-2405; mfarrar@uwyo.edu , ASTM Staff Contact:, Daniel Smith, Phone: 610-832-9727; dsmith@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9623
-
A proposed new ASTM International standard will be used for testing the asphalt used in common pavements. ASTM WK40799 , Practice for Recovery of Asphalt from Solution Using Toluene and the Rotary Evaporator, is being developed by Subcommittee D04.25 on Analysis of Bituminous Mixtures , part of ASTM International Committee D04 on Road and Paving Materials . Asphalt pavements comprise mostly…, ASTM Committee D04 Next Meeting:, Dec. 10-12, 2013, December Committee Week, Jacksonville, Fla., Technical Contact:, Phillip Blankenship, P.E., Asphalt Institute, Lexington, Ky., Phone: 859-288-4986; pblankenship@asphaltinstitute.org, ASTM Staff Contact:, Daniel Smith, Phone: 610-832-9727; dsmith@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9530
-
A wildland-urban interface is a transitional zone between unoccupied land and human development. There are currently more than 40 million homes located within WUI areas throughout the United States. A proposed new ASTM standard will be used to alleviate the issue of fire conditions that exist due to eaves and other projections in structures that exist in WUI areas. ASTM WK37414, Test Method for…, ASTM Committee E05 Next Meeting:, June 23-26, 2014, June Committee Week, Toronto, Ontario, Canada, Technical Contact:, John Simontacchi, Firefree Coatings Inc., San Rafael, Calif., Phone: 415-459-6488; jsimontacchi@firefree.com , ASTM Staff Contact:, Thomas O’Toole, Phone: 610-832-9739; totoole@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9529
-
Rotational viscometry is an easily used tool for determining the viscosity of fluids, including paints, petroleum products and polymer solutions. While standards often make use of rotational viscometry, a procedure for calibrating or validating the measurement is not always part of the standard, which could lead to results that differ from one laboratory to another. A proposed user viscosity…, ASTM Committee E37 Next Meeting:, March 14, 2014, ASTM International Headquarters, West Conshohocken, Pa., Technical Contact:, Roger Blaine, Corvallis, Ore., Phone: 302-559-6827; roger.l.blaine@gmail.com, ASTM Staff Contact:, Tom O'Toole, Phone: 610-832-9739; totoole@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9493
-
Appearing on the market around the year 2000, lean duplex stainless steels were developed as alternatives both to more traditional duplex grades as well as duplex substitutions for standard austenitic stainless steels. A new standard for such steels, ASTM A1084 , Test Method for Detecting Detrimental Phases in Lean Duplex Austenitic/Ferritic Stainless Steels, has just been approved. A1084 was…, ASTM Committee A01 Next Meeting:, Nov. 11-14, 2013, November Committee Week, Jacksonville, Fla., Technical Contact:, Poul-Erik Arnvig, Outokumpu Stainless AB, Degerfors, Sweden, Phone: +46 (0) 586-47-255; poul-erik.arnvig@outokumpu.com, ASTM Staff Contact:, Kevin Shanahan, Phone: 610-832-9737; kshanahan@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9484