Search
Advanced search
Filter by category
Filter by committee
Search results
-
A proposed new ASTM International test method will be used by ready-mix concrete producers to characterize the drying behavior of new and existing concrete mixture proportions. ASTM WK37029 , Test Method for Measurement of Mass Loss Versus Time for One-Dimensional Drying of Saturated Concretes, is being developed by Subcommittee C09.66 on Concrete’s Resistance to Fluid Penetration , part of ASTM…, ASTM Committee C09 Next Meeting:, Dec. 8-11, 2013, December Committee Week, Jacksonville, Fla., Technical Contact:, Dale P. Bentz, National Institute of Standards and Technology, Gaithersburg, Md., Phone: 301-975-5865; dale.bentz@nist.gov , ASTM Staff Contact:, Scott Orthey, Phone: 610-832-9730; sorthey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9390
-
A proposed new ASTM International standard will cover the process, verification and record keeping procedures for recycling returned fresh concrete. The proposed standard, ASTM WK39876 , Specification for Returned Fresh Concrete for Use in a New Batch of Ready-Mixed Concrete, is being developed by Subcommittee C09.40 on Ready-Mixed Concrete , part of ASTM International Committee C09 on Concrete…, ASTM Committee C09 Next Meeting:, June 9-12, 2013, June Committee Week, Indianapolis, Ind., Technical Contact:, Eric P. Koehler, Verifi LLC, Cambridge, Mass., Phone: 617-498-4354; eric.koehler@verifitechnologies.com, ASTM Staff Contact:, Scott Orthey, Phone: 610-832-9730; sorthey@astm.org , ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9329
-
Prestressing concrete has existed in the construction industry for more than 100 years, but without a repeatable and reproducible test capable of quantifying the bond performance of prestressing steel wire strand (commonly called PC strand). This test has now been developed in the form of ASTM A1081/A1081M , Test Method for Evaluating Bond of Seven-Wire Steel Prestressing Strand. ASTM A1081/…, ASTM Committee A01 Next Meeting:, May 20-23, 2013, May Committee Week, Indianapolis, Ind., Technical Contact:, Christopher F. Reeve, Insteel Wire Products, Gallatin, Tenn., Phone: 615-451-6330, ext. 2762; creeve@insteel.com, ASTM Staff Contact:, Kevin Shanahan, Phone: 610-832-9737; kshanahan@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9325
-
A proposed new ASTM test method will be used to quantify the resistivity of concreting materials that are widely used for construction around the world. ASTM WK37880 , Test Method for Measuring the Surface Resistivity of Hardened Concrete Using the Wenner Four-Electrode Method, is being developed by Subcommittee C09.66 on Concrete’s Resistance to Fluid Penetration , part of ASTM International…, ASTM Committee C09 Next Meeting:, June 9-12, 2013, June Committee Week, Indianapolis, Ind., Technical Contact:, Kenneth A. Snyder, National Institute of Standards and Technology, Gaithersburg, Md., Phone: 301-975-4260; kenneth.snyder@nist.gov, ASTM Staff Contact:, Scott Orthey; Phone: 610-832-9730; sorthey@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9321
-
Bolting used in the oil and gas industries for offshore drilling platforms, sour gas service, in expanders and compressors in pipeline service, in power generation facilities and in heat exchanger and cryogenic applications is now covered by a new ASTM International standard. ASTM A1082/A1082M , Specification for High Strength Precipitation Hardening and Duplex Stainless Steel Bolting for Special…, ASTM Committee A01 Next Meeting:, May 20-23, 2013, May Committee Week, Indianapolis, Ind., Technical Contact:, Lester Burgess, TSP/US Bolt Manufacturing, Houston, Texas, Phone: 713-230-2500; lburgess@usbolt.com, ASTM Staff Contact:, Kevin Shanahan, Phone: 610-832-9737; kshanahan@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org Release #9308
-
A general need in the steel industry for a standard defining the basic quality control requirements for hot isostatic pressing has led to the development of a new ASTM International standard, ASTM A1080 , Practice for Hot Isostatic Pressing of Steel, Stainless Steel and Related Alloy Castings. A1080 was developed by Subcommittee A01.18 on Castings , part of ASTM International Committee A01 on…, ASTM Committee A01 Next Meeting:, Nov. 12-15, 2012, November Committee Week, Atlanta, Ga., Technical Contact:, John Schleicher, Orchid Orthopedics, Oregon City, Ore., Phone: 503-650-2708; john.schleicher@orchid-ortho.com, ASTM Staff Contact:, Kevin Shanahan, Phone: 610-832-9737; kshanahan@astm.org, ASTM PR Contact:, Barbara Schindler, Phone: 610-832-9603; bschindl@astm.org R elease #9255
-
ASTM International Committee A01 on Steel, Stainless Steel and Related Alloys encourages all interested parties to contribute to the ongoing revision of ASTM A262 , Practices for Detecting Susceptibility to Intergranular Attack in Austenitic Stainless Steels. ASTM A262 is a widely referenced standard under the jurisdiction of Subcommittee A01.14 on Methods of Corrosion Testing . The standard is…
-
A proposed new ASTM standard will provide proper direction and ensure adequate documentation to aid in the interpretation, understanding and reduction of variance in test results for fiber-reinforced concrete. ASTM WK35250 , Practice for Fiber-Reinforced Concrete for Making and Curing Test Specimens in the Laboratory and Field, is now being developed by Subcommittee C09.42 on Fiber-Reinforced…
-
Formalizing a method for making a cylindrical specimen of roller-compacted concrete in a gyratory compactor is the primary purpose of a proposed new ASTM International standard. ASTM WK33682 , Test Method for Preparation, Compaction and Density Determination of Roller-Compacted Concrete Specimens by Means of the Superpave Gyratory Compactor, is being developed by Subcommittee C09.45 on Roller-…
-
While the use of internally cured concrete in construction is not new, there is now better understanding of the internal curing process and why IC using pre-wetted lightweight aggregate increases concrete durability and service life in an economical and practical way. However, there is not currently a standard for lightweight aggregates for internal curing. ASTM International Committee C09 on…